Effects of Hemoglobin C and S Traits on Eight Glycohemoglobin Methods

Roberts, William L, De, Barun K, Brown, Diane, Hanbury, C Michael, Hoyer, James D, John, W Garry, Lambert, Thomas L, Lundell, Ryan B, Rohlfing, Curt, Little, Randie R · 2002 · Clinical Chemistry
Cited by 70

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Glycohemoglobin (gHb) is a biochemical marker of long-term glycemic control that is highly correlated with complications of diabetes mellitus (1). The presence of hemoglobin (Hb) variants can adversely affect the accuracy of some gHb methods, depending on the variant [for recent reviews, see Refs. (2)(3)]. Previous studies have shown that some gHb methods yield inaccurate results with samples heterozygous for Hb C or S (4)(5)(6)(7). In 2000, there were an estimated 26 million black or African Americans over age 17, of whom at least 10% had either Hb C or S trait (8)(9)(10)(11). The prevalence of diabetes is estimated to be 5.1% of the adult population, with rates for non-Hispanic blacks 1.6 times greater than in non-Hispanic whites (12). It is therefore probable that at least 200 000 Americans with diabetes have either Hb C or S trait. We investigated the measurement of gHb in specimens containing Hb C or S trait, using eight commercial gHb methods that are currently in clinical use. Whole blood samples from individuals homozygous for Hb A (n = 43) and heterozygous for Hb C or S (n = 43 and 61, respectively) were collected in EDTA tubes. Hb variants were identified by their characteristic chromatograms obtained with a VARIANT analyzer (Bio-Rad Laboratories) operated according to the manufacturer’s instructions and using a Beta Thal Short program. Aliquots of these samples, containing 4–14% Hb A1c, were stored at 2–8 °C and analyzed within 10 days of collection. This study was approved by the Institutional Review Board of the University of Utah Health Sciences Center. The CLC 330 gHb analyzer (Primus Corporation) was operated at the University of Missouri. This method was chosen as the comparative method for this study because results from boronate affinity chromatography are not expected to be influenced by the presence of Hb variants (13)(14)(15)(16). The following methods/instruments were evaluated: Cobas INTEGRA 700 Hemoglobin A1c whole blood application (Roche Diagnostics Corporation), Glyco-Tek affinity column method (Helena Laboratories), Glycosal HbA1c (Provalis Diagnostics), HA8140 analyzer (Menarini Diagnostics), Nycocard HbA1c (Primus Corporation), Synchron CX7 (Beckman Coulter, Inc.), and VARIANT II HbA1c and VARIANT Total GHb analyzers (Bio-Rad Laboratories). All of these methods are certified by the National Glycohemoglobin Standardization Program (NGSP; June 2001) except for the Glyco-Tek method (17). CLC 330 HPLC analyses were performed in a NGSP Network Laboratory, using in-house calibrator materials and assigned values. For all other methods, samples were analyzed following the manufacturers’ instructions. For each test method, results for each group of samples (Hb AA, Hb AC, Hb AS) were compared with results from the comparative method (CLC 330). An overall test for coincidence of two least-squares linear regression lines was performed using SAS software (SAS Institute Inc.) to determine whether the presence of Hb C or S trait caused a statistically significant difference (P <0.01) in results relative to the comparison method. Deming regression analysis was performed, using EP Evaluator release 3 software (David G. Rhoads, Kennett Square, PA), to determine whether the presence of Hb C and S traits produced clinically significant effects. Given the Diabetes Control and Complications Trial Reference Method upper reference limit of 6% and the American Diabetes Association goal and action limits of 7% and 8%, respectively, 6% and 9% Hb A1c were chosen as important evaluation limits. Given the need to clearly distinguish the difference among 6%, 7%, and 8% Hb A1c, a >10% deviation (0.6% at 6% Hb A1c and 0.9% at 9% Hb A1c) compared with the Hb AA sample group was used to define a clinically significant difference. The presence of Hb C produced statistically significant differences for all methods tested except the HA8140, Nycocard, and Synchron CX7 methods. The presence of Hb S trait produced statistically significant differences for all methods except the Nycocard and Synchron CX7 methods. Box plots for each group of samples and for each method are shown in Fig. 1. No clinically significant interference attributable to Hb AC or Hb AS was seen with the Nycocard, Synchron CX7, VARIANT GHb, and VARIANT II methods (Table 1). Both Hb AC and Hb AS produced clinically significant positive interferences for the Cobas INTEGRA method. The presence of Hb AC produced a clinically significant positive interference for the Glyco-Tek method at both 6% and 9% Hb A1c and a borderline clinically significant positive interference for the Glycosal method at 6% Hb A1c. The HA8140 method showed clinically significant interference from Hb AS at 6% Hb A1c, but not from Hb AC. The increased scatter observed with the Cobas INTEGRA and VARIANT GHb methods for samples containing Hb C or S trait compared with Hb AA samples was also noteworthy. Box-plots summarizing the absolute differences between each test method and the

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/48.2.383

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 9

  1. 1998, Med Clin North Am, 82, 665, 10.1016/S0025-7125(05)70019-5 · DOI
  2. 2001, Diabetes Metab Res Rev, 17, 94, 10.1002/dmrr.186 · DOI
  3. 1998, Diabetes Care, 21, 983, 10.2337/diacare.21.6.983 · DOI · Paper page
  4. 2000, Clin Chem, 46, 864, 10.1093/clinchem/46.6.864 · DOI
  5. 1987, Am J Hematol, 24, 429, 10.1002/ajh.2830240413 · DOI
  6. 1985, Glycosylated hemoglobins, 91
  7. 1988, J Chromatogr, 429, 279, 10.1016/S0378-4347(00)83874-8 · DOI
  8. 1997, Clin Chem, 43, 76, 10.1093/clinchem/43.1.76 · DOI
  9. 1997, Clin Chem, 43, 968, 10.1093/clinchem/43.6.968 · DOI · Paper page

Cited by

See all 70

Metadata

Authors
Roberts, W. L., De, B. K., Brown, D., Hanbury, C. M., Hoyer, J. D., John, W. G., Lambert, T. L., Lundell, R. B., Rohlfing, C., & Little, R. R.
Venue
Clinical Chemistry
Published
2002-02-01
Volume
48
Issue
2
Pages
383-385
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1899323999
Cited by
70
References
5
FWCI
1.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.