CoChat

β-Trace Protein, Cystatin C, β2-Microglobulin, and Creatinine Compared for Detecting Impaired Glomerular Filtration Rates in Children

Filler, Guido, Priem, Friedrich, Lepage, Nathalie, Sinha, Pranav, Vollmer, Ilka, Clark, Heather, Keely, Erin, Matzinger, Mary, Akbari, Ayub, Althaus, Harald, Jung, Klaus · 2002 · Clinical Chemistry
Cited by 206

The DOI matches its Crossref record.

Abstract

Background: Because of the limitations of serum creatinine as a marker of glomerular filtration rate (GFR) in children, we assessed the diagnostic accuracy of the novel marker β-trace protein (BTP) in comparison with cystatin C (Cys-C), β2-microglobulin (β2-MG), and creatinine as conventional indicators of reduced GFR. Methods: We obtained serum samples from 225 children (age range, 0.2–18 years) with various renal pathologies who were referred for nuclear medicine clearance investigations (technetium-diethylenetriamine pentaacetic acid or chromium-EDTA). We measured Cys-C, BTP (nephelometric tests; Dade Behring), β2-MG (Tinaquant; Roche), and creatinine (enzymatic assay; Creatinine-PAP; Roche). Results: Seventy-five children had reduced GFR (<90 mL · min−1 · 1.73 m−2). One hundred fifty children (independent of gender and age) with values >90 mL · min−1 · 1.73 m−2 comprised the control group with gaussian distributions of BTP and Cys-C concentrations. The upper reference limits (97.5 percentile) were 1.01 mg/L for BTP and 1.20 mg/L for Cys-C. The correlations of nuclear medicine clearance with the reciprocals of BTP, Cys-C, and the Schwartz GFR estimate were significantly higher (r = 0.653, 0.765, and 0.706, respectively; P <0.05) than with the reciprocal of creatinine or β2-MG (r = 0.500 and 0.557, respectively). ROC analysis showed a significantly higher diagnostic accuracy of BTP, Cys-C, and the GFR estimate for the detection of impaired GFR than serum creatinine (P <0.05). Compared to creatinine, BTP increased the diagnostic sensitivity by ∼30%, but it was not more sensitive than Cys-C or the Schwartz GFR estimate. Conclusions: BTP is superior to serum creatinine and an alternative for Cys-C to detect mildly reduced GFR in children, but it is not better than the Schwartz GFR estimate.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/48.5.729

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Filler, G., Priem, F., Lepage, N., Sinha, P., Vollmer, I., Clark, H., Keely, E., Matzinger, M., Akbari, A., Althaus, H., & Jung, K.
Venue
Clinical Chemistry
Published
2002-05-01
Volume
48
Issue
5
Pages
729-736
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1907910144
Cited by
206
References
0
FWCI
5.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.