CoChat
Cited by 159

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Diagnostic Value of Plasma Cystatin C as a Glomerular Filtration Marker in Decompensated Liver Cirrhosis

Orlando, Rocco, Mussap, Michele, Plebani, Mario, Piccoli, Pierpaolo, De Martin, Sara, Floreani, Maura, Padrini, Roberto, Palatini, Pietro · 2002 · Clinical Chemistry

Abstract

Background: Plasma creatinine concentration and calculated creatinine clearance are of limited value as glomerular filtration rate (GFR) markers in patients with decompensated liver cirrhosis. We assessed plasma cystatin C as an indicator of GFR in such patients. Methods: We studied 36 patients with decompensated liver cirrhosis and 56 noncirrhotic controls, both groups including individuals with normal and impaired renal function. GFR was measured in all individuals by inulin clearance, with values <72 mL · min−1 · 1.73 m−2 considered decreased. We measured cystatin C and creatinine in plasma and calculated (from plasma concentrations) and measured creatinine clearances, using for them decision points of 1.25 mg/L, 115 μmol/L, and 72 and 72 mL · min−1 · 1.73 m−2, respectively. Results: Plasma cystatin C concentrations were similar in controls and cirrhotics and, at the usual cutpoint, could detect decreased GFR with similar sensitivities in the two groups (73% and 88%, respectively). Serum creatinine was markedly lower in cirrhotics and remained mostly within the reference interval at all GFR values; the diagnostic sensitivity of creatinine was much lower in cirrhotics than in controls (23% vs 64%). Lower diagnostic sensitivity was also observed for calculated creatinine clearance (53% vs 100% in controls), whereas similar sensitivities were found for measured creatinine clearance (86% and 81%) in controls and cirrhotics, respectively. ROC analysis showed that all four variables had similar diagnostic accuracies in cirrhotic patients. However, it also revealed that good diagnostic accuracies for plasma creatinine and calculated creatinine clearance can be obtained only if reference intervals different from those used for the general population are adopted. Conclusions: Plasma cystatin C concentration is an accurate GFR marker in cirrhotic patients. Plasma creatinine concentration and calculated creatinine clearance are of no practical value, as their reference values vary with the severity of the liver disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/48.6.850

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 159

Metadata

Authors
Orlando, R., Mussap, M., Plebani, M., Piccoli, P., De Martin, S., Floreani, M., Padrini, R., & Palatini, P.
Venue
Clinical Chemistry
Published
2002-06-01
Volume
48
Issue
6
Pages
850-858
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1920547475
Cited by
159
References
2
FWCI
4.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.