CoChat

Setting Performance Goals and Evaluating Total Analytical Error for Diagnostic Assays

Krouwer, Jan S · 2002 · Clinical Chemistry
Cited by 68

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background: Total analytical error has been a useful metric both to assess laboratory assay quality and to set goals. It is often estimated by combining imprecision (SD) and average bias in the equation: total analytical error = bias + 1.65 × imprecision. This indirect estimation model (referred to as the simple combination model) leads to different estimates of total analytical error than that of a direct estimation method (referred to as the distribution-of-differences method) or of simulation. Methods: A review of the literature was undertaken to reconcile the different estimation approaches. Results: The simple combination model can underestimate total analytical error by neglecting random interference bias and by not properly treating other error sources such as linear drift and outliers. A simulation method to estimate total analytical error is outlined, based on the estimation and combination of total analytical error source distributions. Goals for each total analytical error source can be established by allocation of the total analytical error goal. Typically, the allocation is cost-based and uses the probability of combinations of error sources. The distribution-of-differences method, simple combination model, and simulation method to evaluate total analytical error are compared. Outlier results can profoundly influence quality, but their rates are seldom reported. Conclusions: Total analytical error should be estimated either directly by the distribution-of-differences method or by simulation. A systems engineering approach that uses allocation of the total analytical error goal into error source goals provides a cost-effective approach to meeting total analytical error. Because outliers can cause serious laboratory error, the inclusion of outlier rate estimates from large studies (e.g., those conducted by manufacturers) would be helpful in assessing assay quality.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/48.6.919

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Metadata

Authors
Krouwer, J. S.
Venue
Clinical Chemistry
Published
2002-06-01
Volume
48
Issue
6
Pages
919-927
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2154056227
Cited by
68
References
1
FWCI
1.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Setting Performance Goals and Evaluating Total Analytical Error for Diagnostic Assays. https://app.cochat.ai/papers/10.1093/clinchem/48.6.919
The paper
Krouwer, J. S. (2002). Setting Performance Goals and Evaluating Total Analytical Error for Diagnostic Assays. Clinical Chemistry. https://doi.org/10.1093/clinchem/48.6.919

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.