Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 178

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Biological Variation of Glycohemoglobin

Rohlfing, Curt, Wiedmeyer, Hsiao-Mei, Little, Randie, Grotz, V Lee, Tennill, Alethea, England, Jack, Madsen, Richard, Goldstein, David · 2002 · Clinical Chemistry

Abstract

Glycohemoglobin (GHb) is a measure of long-term mean glycemia that predicts risks for the development and/or progression of diabetic complications in patients with type 1 and type 2 diabetes (1)(2). Several reports have suggested, however, that although the within-subject variation in GHb unrelated to glycemia is minimal, there is substantial between-subject variation in GHb, e.g., “low glycators” and “high glycators” (3)(4)(5). These reports have suggested that because of this large between-subject variation, GHb may not be useful for diabetes screening or diagnosis and that when GHb is used for routine management of patients with diabetes, different patients may require very different GHb target values to achieve the same overall glycemic status. We therefore examined the biological variation of GHb and fasting plasma glucose (FPG) in nondiabetic individuals. Individuals without diabetes (n = 48) participated in a study of an artificial sweetener that has no effect on GHb or plasma glucose concentrations [Submission to Food and Drug Administration. McNeil Specialty Products Company food additive petition 7A3987 (Sucralose), 1987–1997]. Because the study was designed to detect minimal changes in plasma glucose concentrations, all participants were men to avoid the effects of cyclic hormonal changes on insulin (and therefore, plasma glucose) concentrations. At the prestudy screening, all individuals were healthy on the basis of a medical history, physical examination, and electrocardiography results; results of hematology and blood chemistry studies, urine examination, and measures of blood glucose control (FPG, insulin, C-peptide, and hemoglobin A1c) were all within their respective reference intervals. Participants who failed a baseline oral glucose tolerance test [fasting >7.8 mmol/L (140 mg/dL), 1 h >11.1 mmol/L (200 mg/dL), and/or 2 h >7.8 mmol/L (140 mg/dL)] were excluded. Those who took medications that could affect glucose metabolism or who failed a drugs-of-abuse screen, had a history of a gastrointestinal disorder, or had a history of consuming more than two alcoholic drinks per day were also excluded. Serial samples for FPG and GHb analysis were collected by venipuncture after a minimum 8-h overnight fast on a weekly basis for a total of 12 visits. Three men with <10 data points for either FPG or GHb were excluded from the analysis. The study received approval from the institutional review boards of all participating study centers, and all individuals gave informed consent before their participation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/48.7.1116

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 178

Metadata

Authors
Rohlfing, C., Wiedmeyer, H.-M., Little, R., Grotz, V. L., Tennill, A., England, J., Madsen, R., & Goldstein, D.
Venue
Clinical Chemistry
Published
2002-07-01
Volume
48
Issue
7
Pages
1116-1118
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1901357037
Cited by
178
References
2
FWCI
2.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Biological Variation of Glycohemoglobin. https://app.cochat.ai/papers/10.1093/clinchem/48.7.1116
The paper
Rohlfing, C., Wiedmeyer, H.-M., Little, R., Grotz, V. L., Tennill, A., England, J., Madsen, R., & Goldstein, D. (2002). Biological Variation of Glycohemoglobin. Clinical Chemistry. https://doi.org/10.1093/clinchem/48.7.1116

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.