Personalized reference intervals in laboratory medicine: a new model based on within-subject biological variation.
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The concept of personalized medicine has received widespread attention in the last decade. However, personalized medicine depends on correct diagnosis and monitoring of patients, for which personalized reference intervals for laboratory tests may be beneficial. In this study, we propose a simple model to generate personalized reference intervals based on historical, previously analyzed results, and data on analytical and within-subject biological variation. METHODS: A model using estimates of analytical and within-subject biological variation and previous test results was developed. We modeled the effect of adding an increasing number of measurement results on the estimation of the personal reference interval. We then used laboratory test results from 784 adult patients (>18 years) considered to be in a steady-state condition to calculate personalized reference intervals for 27 commonly requested clinical chemistry and hematology measurands. RESULTS: Increasing the number of measurements had little impact on the total variation around the true homeostatic set point and using ≥3 previous measurement results delivered robust personalized reference intervals. The personalized reference intervals of the study participants were different from one another and, as expected, located within the common reference interval. However, in general they made up only a small proportion of the population-based reference interval. CONCLUSIONS: Our study shows that, if using results from patients in steady state, only a few previous test results and reliable estimates of within-subject biological variation are required to calculate personalized reference intervals. This may be highly valuable for diagnosing patients as well as for follow-up and treatment.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Tietz Textbook of Clinical Chemistry and Molecular Diagnostics
Burtis, E. B. C. A., Ashwood, E. R., & Bruns, D. E. (2011) · Medical Entomology and Zoology · Cited by 2,190
Personalized medicine: motivation, challenges, and progress
Goetz, L. H., & Schork, N. J. (2018) · Fertility and Sterility · doi:10.1016/j.fertnstert.2018.05.006 · Cited by 976
Predictive Inference: An Introduction
Geisser, S. (1993) · Springer eBooks · doi:10.1007/978-1-4899-4467-2 · Cited by 917
Biological Variation: From Principles to Practice
Fraser, C. G. (2001) · Cited by 653
(2017) · Routledge eBooks · doi:10.1201/9780203742310 · Cited by 568
Aarsand, A. K., Røraas, T., Fernandez-Calle, P., Ricos, C., Díaz-Garzón, J., Jonker, N., Perich, C., González-Lao, E., Carobene, A., Minchinela, J., et al. (2018) · Clinical Chemistry · doi:10.1373/clinchem.2017.281808 · Cited by 233
Self-citationEstablishment and Use of Reference Values
Horowitz, G. L. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4160-6164-9.00005-6 · Cited by 145
The theory of reference values: an unfinished symphony
Siest, G., Henny, J., Gräsbeck, R., Wilding, P., Petitclerc, C., Queraltó, J. M., & Petersen, P. H. (2013) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2012-0682 · Cited by 122
Coşkun, A., Carobene, A., Kilercik, M., Serteser, M., Sandberg, S., Aarsand, A. K., Fernandez-Calle, P., Jonker, N., Bartlett, W. A., Díaz-Garzón, J., et al. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-1155 · Cited by 62
Self-citationCoskun, A., Braga, F., Carobene, A., Tejedor Ganduxe, X., Aarsand, A. K., Fernández-Calle, P., Díaz-Garzón Marco, J., Bartlett, W., Jonker, N., Aslan, B., et al. (2019) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2019-0658 · Cited by 56
Self-citation
Cited by
The European Biological Variation Study (EuBIVAS): a summary report
Carobene, A., Aarsand, A. K., Bartlett, W. A., Coskun, A., Diaz-Garzon, J., Fernandez-Calle, P., Guerra, E., Jonker, N., Locatelli, M., Plebani, M., et al. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-0370 · Cited by 84
“The data can be used to establish reference change values (RCV) that enable objective assessment of significance of change in serial test results [6, 7], to estimate the number of samples required to calculate the homeostatic set point (NHSP) [7, 8], to assess the utility of conventional population-based reference int…”
MethodSelf-citationBiological variation estimates of Alzheimer's disease plasma biomarkers in healthy individuals
Brum, W. S., Ashton, N. J., Simrén, J., di Molfetta, G., Karikari, T. K., Benedet, A. L., Zimmer, E. R., Lantero‐Rodriguez, J., Montoliu‐Gaya, L., Jeromin, A., et al. (2024) · Alzheimer's & Dementia · doi:10.1002/alz.13518 · Cited by 76
“33,36 European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group on Biological Variation.”
BackgroundInfluentialSelf-citationPersonalized reference intervals: from theory to practice
Coşkun, A., Sandberg, S., Ünsal, İ., Serteser, M., & Aarsand, A. K. (2022) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2022.2070905 · Cited by 67
“However, it is not recommended to calculate TVset for HSP based on a single measurement, because TVset will be 41% higher than the actual level [31].”
BackgroundMethodSelf-citationCoskun, A., Zarepour, A., & Zarrabi, A. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms24076275 · Cited by 61
Self-citationBiological variation: recent development and future challenges
Sandberg, S., Carobene, A., Bartlett, W. A., Coşkun, A., Fernández–Calle, P., Jonker, N., Díaz–Garzón, J., & Aarsand, A. K. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2022-1255 · Cited by 65
Self-citation
Metadata
- Authors
- Coşkun, A., Sandberg, S., Unsal, I., Cavusoglu, C., Serteser, M., Kilercik, M., & Aarsand, A. K.
- Affiliations
- Acıbadem University (TR)
- Haukeland University Hospital (NO)
- Acibadem Labmed Clinical Laboratories
- Corresponding author
- Coşkun, Abdurrahman
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2020-11-14
- Volume
- 67
- Issue
- 2
- Pages
- 374-384
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W3105290805
- Cited by
- 112
- References
- 12
- Citations by year
- 2026: 18 · 2025: 33 · 2024: 16 · 2023: 18 · 2022: 10 · 2021: 17
- FWCI
- 6.76
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- academic.oup.com/journals/pages/open_access/funder_policies/chorus/standard_publication_model (vor)
- Locations
- Clinical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Acibadem University Open Access Repository (submittedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Keywords
- within-subject biological variation, analytical variability, homeostatic set point, hematology, personalized medicine
- MeSH terms
- Biological Variation, Population, Adolescent, Adult, Aged, Female, Hematologic Tests, Humans, Laboratories, Male, Middle Aged, Reference Values, Models, Statistical, Clinical Chemistry Tests, Young Adult, Precision Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Personalized reference intervals in laboratory medicine: a new model based on within-subject biological variation. https://app.cochat.ai/papers/10.1093/clinchem/hvaa233
- The paper
- Coşkun, A., Sandberg, S., Unsal, I., Cavusoglu, C., Serteser, M., Kilercik, M., & Aarsand, A. K. (2021). Personalized reference intervals in laboratory medicine: a new model based on within-subject biological variation. Clinical Chemistry. https://doi.org/10.1093/clinchem/hvaa233
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.