Non-invasive ultrasonic measurement of the elastic properties of the human abdominal aorta
The DOI matches its Crossref record.
Abstract
A new echo tracking device linked to real time ultrasonic B mode equipment was developed to measure non-invasively the elastic properties of the human abdominal aorta. Pulsatile diameter change and mean diameter of the abdominal aorta were measured in 61 subjects with this ultrasonic device. Strain and pressure-strain elastic modulus Ep were calculated from pulsatile diameter change, diameter, and pulse pressure obtained by the auscultatory method. Strain significantly decreased with age; 0.076(0.024) (mean(SD)) in group 1 (20 young adults below the age of 35 years); 0.048(0.024) in group 2 (21 middle aged subjects between the ages of 35 and 60 years); and 0.030(0.010) in group 3 (20 elderly subjects over the age of 60 years). Ep values were 0.99(0.34) X 10(5), 1.55(0.68) X 10(5), and 3.80(2.05) X 10(5) N X m-2 in groups 1, 2, and 3 respectively. Ep in group 3 was significantly higher than in groups 1 and 2. The regression equation relating Ep to age was Ep = (-0.72 + 0.058 X age) X 10(5) N X m-2 (r = 0.73). The Ep value and its age related increase agreed with the findings in postmortem arteries. The elastic properties of the abdominal aorta could, therefore, be determined non-invasively by this ultrasonic method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Salomaa, V., Riley, W., Kark, J. D., Nardo, C., & Folsom, A. R. (1995) · Circulation · doi:10.1161/01.cir.91.5.1432 · Cited by 582
Simons, P. C. G., Algra, A., Bots, M. L., Grobbee, D. E., & van der Graaf, Y. (1999) · Circulation · doi:10.1161/01.cir.100.9.951 · Cited by 349
Diameter and compliance in the human common carotid artery — variations with age and sex
Hansen, F., Mangell, P., Sonesson, B., & Länne, T. (1995) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(94)00090-5 · Cited by 293
Tardy, Y., Meister, J. J., Perret, F., Brunner, H. R., & Arditi, M. (1991) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/12/1/003 · Cited by 270
Compliance and diameter in the human abdominal aorta—The influence of age and sex
Sonesson, B., Hansen, F., Stale, H., & Länne, T. (1993) · European Journal of Vascular Surgery · doi:10.1016/s0950-821x(05)80718-2 · Cited by 252
Khamdaeng, T., Luo, J., Vappou, J., Terdtoon, P., & Konofagou, E. E. (2012) · Ultrasonics · doi:10.1016/j.ultras.2011.09.006 · Cited by 156
Metadata
- Authors
- IMURA, T., YAMAMOTO, K., KANAMORI, K., MIKAMI, T., & YASUDA, H.
- Venue
- Cardiovascular Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1986-03-01
- Volume
- 20
- Issue
- 3
- Pages
- 208-214
- ISSN
- 0008-6363 (ISSN-L)
- OpenAlex
- W2006896558
- Cited by
- 160
- References
- 0
- FWCI
- 1.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.