Simple, rapid, and effective method of producing aortocaval shunts in the rat
The DOI matches its Crossref record.
Abstract
STUDY OBJECTIVE - The aim of the study was to develop a new procedure to produce abdominal aortocaval shunts in the rat without vascular microsurgery. PROCEDURE - The inferior vena cava and abdominal aorta were exposed by laparotomy. The aorta was punctured caudal to the left renal artery with an 18 gauge disposable needle which was advanced into the vessel, perforating the adjacent wall between aorta and vena cava and penetrating the latter. A bulldog vascular clamp was placed across the aorta cephalic to the puncture, the needle was withdrawn, and the aortic puncture point was sealed with a drop of cyanoacrylate glue. The clamp was removed 30 s later. Patency of the shunt was verified visually by swelling of the vena cava and admixture of arterial and venous blood. No local haemorrhages were seen. The laporatomy was then closed. The procedure takes less than 10 min. RESULTS - Of 11 rats which received this procedure, only one died within 24 h. All the other animals were killed 4 weeks after operation. Nine of these 10 animals had developed cardiac hypertrophy of about the same magnitude. There were no changes in sham operated controls. CONCLUSIONS - This is a reproducible, simple and rapid method of developing high output heart failure and cardiac hypertrophy in the rat which could be useful in many laboratories.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rat models of hypertension, cardiac hypertrophy and failure
Doggrell, S. (1998) · Cardiovascular Research · doi:10.1016/s0008-6363(98)00076-5 · Cited by 492
Ikeda, M., Ide, T., Fujino, T., Arai, S., Saku, K., Kakino, T., Tyynismaa, H., Yamasaki, T., Yamada, K.-I., Kang, D., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0119687 · Cited by 152
“The VO HF model was produced by creating an arteriovenous fistula (AVF) using an established protocol.[17] Briefly, 8- to 10 week-old male mice were anesthetized with a mixture of medetomidine (0.”
MethodRat models of cardiovascular diseases
Bader, M. (2010) · Methods in Molecular Biology · doi:10.1007/978-1-60327-389-3_27 · Cited by 63
Metadata
- Authors
- Garcia, R., & Diebold, S.
- Venue
- Cardiovascular Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1990-05-01
- Volume
- 24
- Issue
- 5
- Pages
- 430-432
- ISSN
- 0008-6363 (ISSN-L)
- OpenAlex
- W1970800813
- Cited by
- 235
- References
- 0
- FWCI
- 0.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simple, rapid, and effective method of producing aortocaval shunts in the rat. https://app.cochat.ai/papers/10.1093/cvr/24.5.430
- The paper
- Garcia, R., & Diebold, S. (1990). Simple, rapid, and effective method of producing aortocaval shunts in the rat. Cardiovascular Research. https://doi.org/10.1093/cvr/24.5.430
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.