Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 234

The DOI matches its Crossref record.

Rapid and slow components of delayed rectifier current in human atrial myocytes

Wang, Z., Fermini, B., Nattel, S.·1994·Cardiovascular Research

Abstract

OBJECTIVE: Previous studies in guinea pig heart cells have shown pharmacologically and kinetically distinct components of the classical delayed rectifier current (IK), generally referred to as IKr (rapid IK) and IKs (slow IK). This study was designed to determine whether the human heart contains corresponding components. METHODS: The whole cell voltage clamp technique was used to study IK in single myocytes isolated from human right atrial appendages removed at the time of aortocoronary artery bypass surgery. RESULTS: The activation of IK was best fitted by a biexponential relation, with time constants averaging 204(SEM 20) and 1080(197) ms at +10 mV. IK was inhibited by the specific IKr blocker E-4031 (5 microM), with the drug sensitive and drug resistant components having markedly different kinetic properties. The E-4031 sensitive current activated rapidly, while the drug resistant component activated more slowly, and the activation time courses of E-4031 sensitive and resistant currents paralleled the rapid and slow components of IK between -20 and +50 mV. The E-4031 sensitive component showed strong inward rectification, a half activation voltage (V 1/2) of -14.0(3.3) mV and a slope factor (k) of 6.5(1.5) mV, while the E-4031 resistant current had a linear current-voltage relationship, and values of +19.9(4.2) mV and 12.7(2.5) mV for V 1/2 and k respectively. The envelope of tails analysis showed a time dependent change in IKtail/IKstep under control conditions, and E-4031 strongly reduced the time dependent variation, suggesting that the E-4031 resistant current consisted of one dominant component. CONCLUSIONS: (1) IK in human atrium shows kinetically distinguishable rapid and slow components. (2) These components correspond to E-4031 sensitive and resistant currents. (3) The kinetics and voltage dependence of the rapid (E-4031 sensitive) and slow (E-4031 resistant) components correspond to properties previously described in guinea pig myocytes. These findings have important potential implications for understanding the mechanisms of human atrial repolarisation and its regulation by the autonomic nervous system and antiarrhythmic drugs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/cvr/28.10.1540

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 234

Metadata

Authors
Wang, Z., Fermini, B., & Nattel, S.
Venue
Cardiovascular Research
Published
1994-10-01
Volume
28
Issue
10
Pages
1540-1546
ISSN
0008-6363 (ISSN-L)
OpenAlex
W2116121809
Cited by
234
References
0
FWCI
10.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Rapid and slow components of delayed rectifier current in human atrial myocytes. https://app.cochat.ai/papers/10.1093/cvr/28.10.1540
The paper
Wang, Z., Fermini, B., & Nattel, S. (1994). Rapid and slow components of delayed rectifier current in human atrial myocytes. Cardiovascular Research. https://doi.org/10.1093/cvr/28.10.1540

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.