CoChat

Early repolarization in mice causes overestimation of ventricular activation time by the QRS duration

Boukens, Bas J., Hoogendijk, Mark G., Verkerk, Arie O., Linnenbank, Andre, van Dam, Peter, Remme, Carol-Ann, Fiolet, Jan W., Opthof, Tobias, Christoffels, Vincent M., Coronel, Ruben · 2013 · Cardiovascular Research
Cited by 51

The DOI matches its Crossref record.

Abstract

AIMS: Transgenic mice are frequently used to investigate the role of genes involved in cardiac conduction. The QRS duration calculated from the electrocardiogram (ECG) is a commonly used measure for ventricular conduction time. However, the relation between ventricular activation and QRS duration calculated from a mouse surface ECG is not well understood. We aim to relate ventricular activation and repolarization patterns with the mouse ECG. METHODS AND RESULTS: Ventricular activation and repolarization patterns generated by high-density optical mapping and a six-lead pseudo-ECG were compared in isolated mouse hearts. In addition, mouse ECGs were simulated in silico. Right-ventricular activation ends later than left-ventricular activation. Final activation coincided with the end of the QRS complex in leads III and aVF, but not in leads I, II, aVR, and aVL. The pattern of early repolarization (at 20% of repolarization, RT20) but not of RT50 or RT80 followed the activation pattern. After sodium channel blockade by ajmaline, total ventricular activation time increased by 10.0 ms, whereas QRS duration increased by only 2.1 ms. In mice carrying a mutation in Scn5a (1798insD), ventricular activation ended after the end of the QRS complex (12.9 ± 0.1 vs. 10.8 ± 0.3). CONCLUSION: In the mouse, ventricular myocardium activation and early repolarization waves are simultaneously present. This hampers unequivocal interpretation of the duration of the QRS complex as a measure of ventricular activation duration, especially when conduction is slowed. Under these conditions mapping of local activation and repolarization patterns is required for correct interpretation of the ECG.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/cvr/cvs299

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 51

Metadata

Authors
Boukens, B. J., Hoogendijk, M. G., Verkerk, A. O., Linnenbank, A., van Dam, P., Remme, C.-A., Fiolet, J. W., Opthof, T., Christoffels, V. M., & Coronel, R.
Venue
Cardiovascular Research
Published
2012-09-20
Volume
97
Issue
1
Pages
182-191
ISSN
  • 0008-6363 (ISSN-L)
  • 1755-3245
OpenAlex
W2006856193
Cited by
51
References
0
FWCI
1.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Early repolarization in mice causes overestimation of ventricular activation time by the QRS duration. https://app.cochat.ai/papers/10.1093/cvr/cvs299
The paper
Boukens, B. J., Hoogendijk, M. G., Verkerk, A. O., Linnenbank, A., van Dam, P., Remme, C.-A., Fiolet, J. W., Opthof, T., Christoffels, V. M., & Coronel, R. (2013). Early repolarization in mice causes overestimation of ventricular activation time by the QRS duration. Cardiovascular Research. https://doi.org/10.1093/cvr/cvs299

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.