Millimetre-scale magnetocardiography of living rats with thoracotomy

Open access

The DOI matches its Crossref record; 67 of the 68 references it cites were found in a registry or an index.

Abstract

Abstract Magnetocardiography is a contactless imaging modality for electric current propagation in the cardiovascular system. Although conventional sensors provide sufficiently high sensitivity, their spatial resolution is limited to a centimetre-scale, which is inadequate for revealing the intra-cardiac electrodynamics such as rotational waves associated with ventricular arrhythmias. Here, we demonstrate invasive magnetocardiography of living rats at a millimetre-scale using a quantum sensor based on nitrogen-vacancy centres in diamond. The acquired magnetic images indicate that the cardiac signal source is well explained by vertically distributed current dipoles, pointing from the right atrium base via the Purkinje fibre bundle to the left ventricular apex. We also find that this observation is consistent with and complementary to an alternative picture of electric current density distribution calculated with a stream function method. Our technique will enable the study of the origin and progression of various cardiac arrhythmias, including flutter, fibrillation, and tachycardia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s42005-022-00978-0

Cites

67 of 67 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Magnetocardiography based on a solid-state quantum sensor. a Schematic of the rat magnetocardiography (MCG) setup. A living rat ' s heart remains approximately one millimetre below a diamond chip containing an ensemble of nitrogen-vacancy (NV) centres. The rat is scanned automatically along the XYaxes for magnetic field mapping and manually along the Z-axis for height adjustment. An electrocardiography (ECG) signal is monitored through ECG profilers concurrently with the MCG. The NV centres are excited by a 2.0 W green laser light. This excitation entails spin-state-dependent fluorescence collected by an aspheric condenser lens. b NVcentre energy level diagram. The mS = ±1 ground states are split by a bias magnetic field and mixed by microwaves resonant with the NV transition frequencies. Each of the ground states are further split by hyperfine interactions with the host 14 N nuclear spin. c Enlarged view of the heart and diamond. Electric currents flowing through the heart generate a circulating field (blue arrows). The NV centres (red arrows) along the [111] orientation are sensitive to the Z-component of the magnetic field. d Magnetometry principle. The time-varying cardiac magnetic field (blue), which shifts the NV transition frequency, is converted to a change in the lock-in-demodulated fluorescence signal (red). Five peaks are observed in the lock-in optically detected magnetic resonance (ODMR) spectrum because three hyperfine transition frequencies are excited with three-tone microwaves. e Magnetic field sensitivity across the rat ' s heart signal frequency band of DC ~200 Hz. The black dashed line indicates 140 pT Hz -1/2 .
Fig. 1 Magnetocardiography based on a solid-state quantum sensor. a Schematic of the rat magnetocardiography (MCG) setup. A living rat ' s heart remains approximately one millimetre below a diamond chip containing an ensemble of nitrogen-vacancy (NV) centres. The rat is scanned automatically along the XYaxes for magnetic field mapping and manually along the Z-axis for height adjustment. An electrocardiography (ECG) signal is monitored through ECG profilers concurrently with the MCG. The NV centres are excited by a 2.0 W green laser light. This excitation entails spin-state-dependent fluorescence collected by an aspheric condenser lens. b NVcentre energy level diagram. The mS = ±1 ground states are split by a bias magnetic field and mixed by microwaves resonant with the NV transition frequencies. Each of the ground states are further split by hyperfine interactions with the host 14 N nuclear spin. c Enlarged view of the heart and diamond. Electric currents flowing through the heart generate a circulating field (blue arrows). The NV centres (red arrows) along the [111] orientation are sensitive to the Z-component of the magnetic field. d Magnetometry principle. The time-varying cardiac magnetic field (blue), which shifts the NV transition frequency, is converted to a change in the lock-in-demodulated fluorescence signal (red). Five peaks are observed in the lock-in optically detected magnetic resonance (ODMR) spectrum because three hyperfine transition frequencies are excited with three-tone microwaves. e Magnetic field sensitivity across the rat ' s heart signal frequency band of DC ~200 Hz. The black dashed line indicates 140 pT Hz -1/2 .CC-BY · From the PDF
Fig. 2 Time-domain cardiac magnetic field signal. a -d Typical time-domain magneto-cardiac signal from rats A, B, C, and D, detected with the solid-state quantum sensor (rats A -C) and an optically pumped magnetometer (OPM) (rat D). The insets show electrocardiography (ECG) signals recorded simultaneously. The peaks correspond to the R-wave, the repetition rate of which matches that of ECG. e Dependence of the cardiac magnetic field strength at the R-wave peak on the standoff distance d from the heart centre to the sensor. The vertical error bars reflect an indeterminacy of the sensor position in the XY direction relative to the point of the maximal magnetic field. The horizontal error bars represent the systematic error due to an inaccuracy in measuring the standoff distance. The grey dashed line is the magnetic field calculated from a multiple-current-dipole model with a total dipole Q ¼ ð 1 : 4 ± 0 : 2 Þ ´ 10 3 μ Amm(fitted). The grey shaded area also reflects an indeterminacy of the sensor position. The pink shaded area represents the heart domain. f Dependence of the measurement signal-to-noise ratio (SNR) on the number of averages of the cardiac pulse N ave. Dashed lines show the fitted model SNR / N 1 = 2 ave . For the solid-state quantum sensor (rats A -C), square-root dependence is observed. By contrast, for the OPM, the SNR saturates at ~40, possibly due to the residual environmental magnetic field that cannot be removed by the magnetic shield. Error bars are calculated from the signal, measurement noise, and the number of averages.
Fig. 2 Time-domain cardiac magnetic field signal. a -d Typical time-domain magneto-cardiac signal from rats A, B, C, and D, detected with the solid-state quantum sensor (rats A -C) and an optically pumped magnetometer (OPM) (rat D). The insets show electrocardiography (ECG) signals recorded simultaneously. The peaks correspond to the R-wave, the repetition rate of which matches that of ECG. e Dependence of the cardiac magnetic field strength at the R-wave peak on the standoff distance d from the heart centre to the sensor. The vertical error bars reflect an indeterminacy of the sensor position in the XY direction relative to the point of the maximal magnetic field. The horizontal error bars represent the systematic error due to an inaccuracy in measuring the standoff distance. The grey dashed line is the magnetic field calculated from a multiple-current-dipole model with a total dipole Q ¼ ð 1 : 4 ± 0 : 2 Þ ´ 10 3 μ Amm(fitted). The grey shaded area also reflects an indeterminacy of the sensor position. The pink shaded area represents the heart domain. f Dependence of the measurement signal-to-noise ratio (SNR) on the number of averages of the cardiac pulse N ave. Dashed lines show the fitted model SNR / N 1 = 2 ave . For the solid-state quantum sensor (rats A -C), square-root dependence is observed. By contrast, for the OPM, the SNR saturates at ~40, possibly due to the residual environmental magnetic field that cannot be removed by the magnetic shield. Error bars are calculated from the signal, measurement noise, and the number of averages.CC-BY · From the PDF
Fig. 3 Millimetre-scale cardiac magnetic field mapping. a Optical image of the rat ' s heart. b , c Measured magnetic field map at the timing of the R-wave peak obtained with the nitrogen-vacancy (NV) centres for d NV ¼ 7 : 5 ± 0 : 5 mm and with the optically pumped magnetometer (OPM) for d OPM ¼ 14 ± 2 mm, respectively. The field of view is the same as that of the optical image, with an accuracy of better than 2 mm. The superimposed grey solid line shows the contour of the rat ' s heart traced from the magnetic resonance imaging (MRI) ( d ). d Magnetic resonance image of the rat ' s heart, the orientation of which is adjusted to the optical image. The Purkinje fibre bundle is located in the inner ventricular walls between the left and right ventricular. e , f Fitted magnetic field map using the multiplecurrent-dipole model, superimposed on the contour of the internal structure of the rat ' s heart (grey dashed line) revealed by MRI ( d ). The black arrows represent the location, direction, and relative magnitude of the central dipole. The black dash-dotted circle depicts the localisation precision of the central dipole. The current dipoles are estimated such that the mean squared error between the measured and simulated magnetic fields is minimal.
Fig. 3 Millimetre-scale cardiac magnetic field mapping. a Optical image of the rat ' s heart. b , c Measured magnetic field map at the timing of the R-wave peak obtained with the nitrogen-vacancy (NV) centres for d NV ¼ 7 : 5 ± 0 : 5 mm and with the optically pumped magnetometer (OPM) for d OPM ¼ 14 ± 2 mm, respectively. The field of view is the same as that of the optical image, with an accuracy of better than 2 mm. The superimposed grey solid line shows the contour of the rat ' s heart traced from the magnetic resonance imaging (MRI) ( d ). d Magnetic resonance image of the rat ' s heart, the orientation of which is adjusted to the optical image. The Purkinje fibre bundle is located in the inner ventricular walls between the left and right ventricular. e , f Fitted magnetic field map using the multiplecurrent-dipole model, superimposed on the contour of the internal structure of the rat ' s heart (grey dashed line) revealed by MRI ( d ). The black arrows represent the location, direction, and relative magnitude of the central dipole. The black dash-dotted circle depicts the localisation precision of the central dipole. The current dipoles are estimated such that the mean squared error between the measured and simulated magnetic fields is minimal.CC-BY · From the PDF
Fig. 4 Estimation of the spatiotemporal dynamics of the cardiac current. a Measured field map at the R-wave peak, superimposed on the contour of the structure of the rat ' s heart revealed by optical imaging and magnetic resonance imaging (MRI). The black solid line is a linecut connecting the centres of the observed positive and negative magnetic field peaks. b Vector plots of the electric current density calculated using bfieldtools with a standoff distance of d NV Q ¼ 8 : 1 ± 0 : 7 mm. As a guide for an eye, the MRI image is superimposed in greyscale. c Normal component of the electric current density vector with respect to the linecut. The green shaded region shows the uncertainty of the current density estimated from the uncertainty of the standoff distance (one standard deviation) obtained in the dipole fitting. d -f Measured field map ( d ), estimated electric current density ( e ), and electric current density across the linecut ( f ) evaluated at 20 ms after the R-wave peak.
Fig. 4 Estimation of the spatiotemporal dynamics of the cardiac current. a Measured field map at the R-wave peak, superimposed on the contour of the structure of the rat ' s heart revealed by optical imaging and magnetic resonance imaging (MRI). The black solid line is a linecut connecting the centres of the observed positive and negative magnetic field peaks. b Vector plots of the electric current density calculated using bfieldtools with a standoff distance of d NV Q ¼ 8 : 1 ± 0 : 7 mm. As a guide for an eye, the MRI image is superimposed in greyscale. c Normal component of the electric current density vector with respect to the linecut. The green shaded region shows the uncertainty of the current density estimated from the uncertainty of the standoff distance (one standard deviation) obtained in the dipole fitting. d -f Measured field map ( d ), estimated electric current density ( e ), and electric current density across the linecut ( f ) evaluated at 20 ms after the R-wave peak.CC-BY · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 67 references

Cited by

See all 86

Metadata

Authors
Arai, K., Kuwahata, A., Nishitani, D., Fujisaki, I., Matsuki, R., Nishio, Y., Xin, Z., Cao, X., Hatano, Y., Onoda, S., Shinei, C., Miyakawa, M., Taniguchi, T., Yamazaki, M., Teraji, T., Ohshima, T., Hatano, M., Sekino, M., & Iwasaki, T.
Affiliations
  • Tokyo Institute of Technology (JP)
  • Tohoku University (JP)
  • The University of Tokyo (JP)
  • National Institutes for Quantum Science and Technology (JP)
  • National Institute for Materials Science (JP)
  • Nagano Municipal Hospital (JP)
Corresponding author
  • Hatano, Mutsuko
  • Sekino, Masaki
  • Iwasaki, Takayuki
Venue
Communications Physics
Published
2022-08-23
Volume
5
Issue
1
Pages
200(1)-200(10)
ISSN
2399-3650 (ISSN-L)
OpenAlex
W4292697381
Cited by
85
References
68
Citations by year
2026: 15 · 2025: 19 · 2024: 15 · 2023: 33 · 2022: 3
FWCI
7.18
Type
journal article
Language
en
Open access
Licence
Locations
  • Communications Physics (publishedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Institutional Repositories DataBase (IRDB) (submittedVersion)
  • QST-Repository (National Institutes for Quantum and Radiological Science and Technology) (submittedVersion)
Funders
  • MEXT | JST | Precursory Research for Embryonic Science and Technology (JPMJPR20B1)
  • Ministry of Education, Culture, Sports, Science and Technology (JPMXS0118068379, JPMXS0118067395)
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
Keywords
magnetocardiography, nitrogen-vacancy centers, diamond quantum sensors, current dipoles, ventricular arrhythmias, cardiac arrhythmias, thoracotomy, rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Millimetre-scale magnetocardiography of living rats with thoracotomy. https://app.cochat.ai/papers/10.1038/s42005-022-00978-0
The paper
Arai, K., Kuwahata, A., Nishitani, D., Fujisaki, I., Matsuki, R., Nishio, Y., Xin, Z., Cao, X., Hatano, Y., Onoda, S., Shinei, C., Miyakawa, M., Taniguchi, T., Yamazaki, M., Teraji, T., Ohshima, T., Hatano, M., Sekino, M., & Iwasaki, T. (2022). Millimetre-scale magnetocardiography of living rats with thoracotomy. Communications Physics. https://doi.org/10.1038/s42005-022-00978-0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.