CoChat

Abnormal left ventricular rotation and twist in adult patients with corrected tetralogy of Fallot

Open access
Menting, M. E., Eindhoven, J. A., van den Bosch, A. E., Cuypers, J. A. A. E., Ruys, T. P. E., van Dalen, B. M., McGhie, J. S., Witsenburg, M., Helbing, W. A., Geleijnse, M. L., Roos-Hesselink, J. W. · 2014 · European Heart Journal - Cardiovascular Imaging
Cited by 43

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

AIMS: Left ventricular (LV) dysfunction is a major determinant of late adverse clinical outcome in adult patients with tetralogy of Fallot (ToF). Therefore, early detection is important. Speckle-tracking echocardiography (STE) has emerged as a quantitative technique to assess LV function. The aim of this study was to evaluate LV rotation and twist with STE in adult ToF patients and their association with right ventricular (RV) and LV dimensions and function, exercise capacity, and NT-proBNP level. METHODS: Eighty-two ToF patients and 56 healthy controls matched for age and gender underwent echocardiography, electrocardiography, cardiac magnetic resonance imaging (CMR), bicycle ergometry, and NT-proBNP measurement. For STE, short-axis parasternal views were obtained at the LV base and apex. We analysed LV apical and basal rotation curves and calculated LV twist. RESULTS: Of the 82 ToF patients (55% male, age 33 ± 10 years, 98% NYHA I), 58 (71%) had normal twist, but lower than the controls [12.5 (IQR: 6.6) vs. 16.9 (IQR: 8.2) degrees, P = 0.002] mainly due to decreased apical rotation. Twenty-one (26%) patients had abnormal apical rotation which was associated with larger LV dimensions and decreased systolic biventricular function. Multivariable regression analyses showed positive relations of LV twist with biventricular systolic function measured with echocardiography as well as CMR. CONCLUSION: The majority of adults with corrected ToF show a reduced LV twist. Strikingly, one-quarter of these patients have an abnormal apical rotation which is associated with decreased systolic LV and RV function. These findings suggest that abnormal apical rotation is a new objective diagnostic criterion for detection of ventricular dysfunction.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ehjci/jet244

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 43

Metadata

Authors
Menting, M. E., Eindhoven, J. A., van den Bosch, A. E., Cuypers, J. A. A. E., Ruys, T. P. E., van Dalen, B. M., McGhie, J. S., Witsenburg, M., Helbing, W. A., Geleijnse, M. L., & Roos-Hesselink, J. W.
Venue
European Heart Journal - Cardiovascular Imaging
Published
2013-11-28
Volume
15
Issue
5
Pages
566-574
ISSN
  • 2047-2404 (ISSN-L)
  • 2047-2412
OpenAlex
W2109712255
Cited by
43
References
4
FWCI
2.38
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Abnormal left ventricular rotation and twist in adult patients with corrected tetralogy of Fallot. https://app.cochat.ai/papers/10.1093/ehjci/jet244
The paper
Menting, M. E., Eindhoven, J. A., van den Bosch, A. E., Cuypers, J. A. A. E., Ruys, T. P. E., van Dalen, B. M., McGhie, J. S., Witsenburg, M., Helbing, W. A., Geleijnse, M. L., & Roos-Hesselink, J. W. (2014). Abnormal left ventricular rotation and twist in adult patients with corrected tetralogy of Fallot. European Heart Journal - Cardiovascular Imaging. https://doi.org/10.1093/ehjci/jet244

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.