CoChat

Myocardial strain measurement with feature-tracking cardiovascular magnetic resonance: normal values

Open access
Taylor, Robin J., Moody, William E., Umar, Fraz, Edwards, Nicola C., Taylor, Tiffany J., Stegemann, Berthold, Townend, John N., Hor, Kan N., Steeds, Richard P., Mazur, Wojciech, Leyva, Francisco · 2015 · European Heart Journal – Cardiovascular Imaging
Cited by 251

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Abstract

AIMS: Myocardial deformation is a key to clinical decision-making. Feature-tracking cardiovascular magnetic resonance (FT-CMR) provides quantification of motion and strain using standard steady-state in free-precession (SSFP) imaging, which is part of a routine CMR left ventricular (LV) study protocol. An accepted definition of a normal range is essential if this technique is to enter the clinical arena. METHODS AND RESULTS: One hundred healthy individuals, with 10 men and women in each of 5 age deciles from 20 to 70 years, without a history of cardiovascular disease, diabetes, renal impairment, or family history of cardiovascular disease, and with a normal stress echocardiogram, underwent FT-CMR assessment of LV myocardial strain and strain rate using SSFP cines.Peak systolic longitudinal strain (Ell) was -21.3 ± 4.8%, peak systolic circumferential strain (Ecc) was -26.1 ± 3.8%, and peak systolic radial strain (Err) was 39.8 ± 8.3%. On Bland-Altman analyses, peak systolic Ecc had the best inter-observer agreement (bias 0.63 ± 1.29% and 95% CI -1.90 to 3.16) and peak systolic Err the least inter-observer agreement (bias 0.13 ± 6.41 and 95% CI -12.44 to 12.71). There was an increase in the magnitude of peak systolic Ecc with advancing age, which was greatest in subjects over the age of 50 years (R(2) = 0.11, P = 0.003). There were significant gender differences (P < 0.001) in peak systolic Ell, with a greater magnitude of deformation in females (-22.7%) than in males (-19.3%). CONCLUSION: Normal values for myocardial strain measurements using FT-CMR are provided. All circumferential and longitudinal based variables had excellent intra- and inter-observer variability.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ehjci/jev006

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 31 references

Cited by

See all 251

Metadata

Authors
Taylor, R. J., Moody, W. E., Umar, F., Edwards, N. C., Taylor, T. J., Stegemann, B., Townend, J. N., Hor, K. N., Steeds, R. P., Mazur, W., & Leyva, F.
Venue
European Heart Journal – Cardiovascular Imaging
Published
2015-02-23
Volume
16
Issue
8
Pages
871-881
ISSN
  • 2047-2404 (ISSN-L)
  • 2047-2412
OpenAlex
W2112919934
Cited by
251
References
31
FWCI
16.73
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Myocardial strain measurement with feature-tracking cardiovascular magnetic resonance: normal values. https://app.cochat.ai/papers/10.1093/ehjci/jev006
The paper
Taylor, R. J., Moody, W. E., Umar, F., Edwards, N. C., Taylor, T. J., Stegemann, B., Townend, J. N., Hor, K. N., Steeds, R. P., Mazur, W., & Leyva, F. (2015). Myocardial strain measurement with feature-tracking cardiovascular magnetic resonance: normal values. European Heart Journal – Cardiovascular Imaging. https://doi.org/10.1093/ehjci/jev006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.