Normal range and usefulness of right ventricular systolic strain to detect subtle right ventricular systolic abnormalities in patients with heart failure: a multicentre study
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
AIMS: The aim of the present multicentre study was to analyse a large cohort of healthy subjects and patients with a common condition such as heart failure (HF) with the purpose of determining the normal range and the usefulness of right ventricular (RV) systolic strain to detect subtle RV systolic abnormalities using 2D speckle-tracking echocardiography. METHODS AND RESULTS: We analysed 238 healthy subjects and a cohort of 642 patients characterized by asymptomatic patients (n = 216) and patients with HF with preserved (HFpEF) and reduced (HFrEF) ejection fraction (n = 218 and n = 208, respectively) prospectively included in 10 centres. The normal range of RV systolic strain analysing the healthy subjects was as follows: RV global strain -24.5 ± 3.8 and RV free wall strain -28.5 ± 4.8 (lowest expected value -17 and -19%, respectively). Concerning the ability of these myocardial parameters to detect subtle RV systolic abnormalities, RV global and free wall systolic strain were able to detect subtle RV longitudinal systolic abnormalities in a significant proportion of patients with HFrEF and to a lesser extent in HFpEF despite preserved tricuspid annular plane systolic excursion, tricuspid lateral annular peak systolic velocity by pulsed tissue Doppler imaging, and RV fractional area change. In addition, RV global and free wall systolic strain were significantly linked to the symptomatic status of the patients. CONCLUSIONS: The findings from this study provide important data regarding the normal range of RV global and free wall systolic strain and highlight the clinical relevance of these RV myocardial parameters to detect subtle RV systolic abnormalities in patients with HF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2013 ACCF/AHA Guideline for the Management of Heart Failure
Yancy, C. W., Jessup, M., Bozkurt, B., Butler, J., Casey, D. E., Drazner, M. H., Fonarow, G. C., Geraci, S. A., Horwich, T., Januzzi, J. L., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.05.019 · Cited by 12,536
Lang, R. M., Badano, L. P., Mor-Avi, V., Afilalo, J., Armstrong, A., Ernande, L., Flachskampf, F. A., Foster, E., Goldstein, S. A., Kuznetsova, T., et al. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.10.003 · Cited by 12,362
Lang, R. M., Badano, L. P., Mor-Avi, V., Afilalo, J., Armstrong, A., Ernande, L., Flachskampf, F. A., Foster, E., Goldstein, S. A., Kuznetsova, T., et al. (2015) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jev014 · Cited by 8,361 · cited 8×
“5 cm/s, and FAC ≥ 35%.(2) In this regard, subtle RV systolic abnormalities were defined as those detected when conventional RV systolic measurements were normal.”
BackgroundMethodInfluentialRudski, L. G., Lai, W. W., Afilalo, J., Hua, L., Handschumacher, M. D., Chandrasekaran, K., Solomon, S. D., Louie, E. K., & Schiller, N. B. (2010) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2010.05.010 · Cited by 7,049
ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure 2012
Authors/Task Force Members, McMurray, J. J. V., Adamopoulos, S., Anker, S. D., Auricchio, A., Böhm, M., Dickstein, K., Falk, V., Filippatos, G., Fonseca, C., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs104 · Cited by 6,879
Self-citationRecommendations for the Evaluation of Left Ventricular Diastolic Function by Echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelista, A. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.11.023 · Cited by 4,367
Recommendations for the evaluation of left ventricular diastolic function by echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelisa, A. (2008) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep007 · Cited by 3,351 · cited 4×
“septal or lateral mitral annular early-diastolic (e′) peak velocity ,8 or ,10 cm/s using TDI, respectively, or maximal LA volume index (LAVI) ≥34 mL/m(2).(21) HFrEF was defined in accordance with the guidelines on HF of the ESC: (a) clinical signs or symptoms of HF (i.”
MethodInfluentialMorris, D. A., Takeuchi, M., Krisper, M., Kohncke, C., Bekfani, T., Carstensen, T., Hassfeld, S., Dorenkamp, M., Otani, K., Takigiku, K., et al. (2015) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeu219 · Cited by 276 · cited 2×
“Furthermore, we analysed the myocardial systolic function of the LV by means of the global longitudinal systolic strain which was derived from the analysis of the LV from the apical four-chamber, two-chamber, and long-axis views.(19,20)”
MethodSelf-citationTakigiku, K., Takeuchi, M., Izumi, C., Yuda, S., Sakata, K., Ohte, N., Tanabe, K., & Nakatani, S. (2012) · Circulation Journal · doi:10.1253/circj.cj-12-0264 · Cited by 261 · cited 4×
“Recent studies evidenced that 2DSTE values of the LV vary between different software packages such as GE, Philips, and Toshiba.18,35 –37 Thus, while there are no data showing a variability between different ultrasound software packages regarding RV strain, we consider that the normal range and cut-off values of RV glo…”
MethodInfluentialSelf-citationGiusca, S., Dambrauskaite, V, Scheurwegs, C., D'hooge, J., Claus, P., Herbots, L., Magro, M., Rademakers, F., Meyns, B., Delcroix, M., et al. (2010) · Heart · doi:10.1136/hrt.2009.171728 · Cited by 230
Risum, N., Ali, S., Olsen, N. T., Jons, C., Khouri, M. G., Lauridsen, T. K., Samad, Z., Velazquez, E. J., Sogaard, P., & Kisslo, J. (2012) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2012.08.007 · Cited by 225
Meris, A., Faletra, F. F., Conca, C., Klersy, C., Regoli, F. D., Klimusina, J., Penco, M., Pasotti, E., Pedrazzini, G. B., Moccetti, T., et al. (2010) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2010.05.009 · Cited by 204
Kempny, A., Diller, G., Orwat, S., Kaleschke, G., Kerckhoff, G., Bunck, A. C., Maintz, D. C., & Baumgartner, H. (2010) · International Journal of Cardiology · doi:10.1016/j.ijcard.2010.09.031 · Cited by 148
Guendouz, S., Rappeneau, S., Nahum, J., Dubois‐Randé, J., Guéret, P., Monin, J., Lim, P., Adnot, S., Hittinger, L., & Damy, T. (2011) · Circulation Journal · doi:10.1253/circj.cj-11-0778 · Cited by 123 · cited 1×
“In accordance with these findings, previous studies have found similar cut-offs of RV global and free wall systolic strain to differentiate a normal from an abnormal RVEF by MRI as well as to determine outcomes in patients with HF and cardiovascular diseases.(8,11,13,16,25,26) In line, the most recent guidelines on ch…”
ResultFine, N. M., Chen, L., Bastiansen, P. M., Frantz, R. P., Pellikka, P. A., Oh, J. K., & Kane, G. C. (2014) · Echocardiography · doi:10.1111/echo.12806 · Cited by 120
Morris, D. A., Gailani, M., Pérez, A. V., Blaschke, F., Dietz, R., Haverkamp, W., & Özcelik, C. (2011) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2011.04.005 · Cited by 108
Self-citationCameli, M., Righini, F. M., Lisi, M., Bennati, E., Navarri, R., Lunghetti, S., Padeletti, M., Cameli, P., Tsioulpas, C., Bernazzali, S., et al. (2013) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2013.07.046 · Cited by 101
Park, J., Negishi, K., Kwon, D. H., Popović, Z., Grimm, R. A., & Marwick, T. H. (2014) · Journal of Cardiovascular Ultrasound · doi:10.4250/jcu.2014.22.3.113 · Cited by 101
Mercer‐Rosa, L., Parnell, A. S., Forfia, P. R., Yang, W. P., Goldmuntz, E., & Kawut, S. M. (2013) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2013.06.022 · Cited by 93
Negishi, K., Lucas, S. D., Negishi, T., Hamilton, J., & Marwick, T. H. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2012.11.021 · Cited by 90
Comparison of Two Different Speckle Tracking Software Systems: Does the Method Matter?
Biaggi, P., Carasso, S., Garceau, P., Greutmann, M., Gruner, C., Tsang, W., Rakowski, H., Agmon, Y., & Woo, A. (2011) · Echocardiography · doi:10.1111/j.1540-8175.2011.01386.x · Cited by 81 · cited 2×
“Recent studies evidenced that 2DSTE values of the LV vary between different software packages such as GE, Philips, and Toshiba.18,35 –37 Thus, while there are no data showing a variability between different ultrasound software packages regarding RV strain, we consider that the normal range and cut-off values of RV glo…”
MethodLi, Y., Xie, M., Wang, X., Lü, Q., & Fu, M. (2012) · International journal of cardiac imaging · doi:10.1007/s10554-012-0114-5 · Cited by 69
Leong, D. P., Grover, S., Molaee, P., Chakrabarty, A., Shirazi, M., Cheng, Y. H., Penhall, A., Perry, R., Greville, H. W., Joseph, M. X., et al. (2011) · Echocardiography · doi:10.1111/j.1540-8175.2011.01594.x · Cited by 65 · cited 2×
“In accordance with these findings, previous studies have found similar cut-offs of RV global and free wall systolic strain to differentiate a normal from an abnormal RVEF by MRI as well as to determine outcomes in patients with HF and cardiovascular diseases.(8,11,13,16,25,26) In line, the most recent guidelines on ch…”
MethodResultvan der Hulst, A. E., Delgado, V., Holman, E. R., Kroft, L. J. M., Roos, A., Hazekamp, M. G., Blom, N. A., Bax, J. J., & Roest, A. A. W. (2010) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2010.04.032 · Cited by 57
Morris, D. A., Otani, K., Bekfani, T., Takigiku, K., Izumi, C., Yuda, S., Sakata, K., Ohte, N., Tanabe, K., Friedrich, K., et al. (2014) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.01.017 · Cited by 56 · cited 2×
“Furthermore, we analysed the myocardial systolic function of the LV by means of the global longitudinal systolic strain which was derived from the analysis of the LV from the apical four-chamber, two-chamber, and long-axis views.(19,20)”
MethodSelf-citationBernard, Y. F., Morel, M., Descotes‐Genon, V., Jehl, J., Meneveau, N. F., & Schiele, F. (2013) · Echocardiography · doi:10.1111/echo.12386 · Cited by 32
Salerno, G., D’Andrea, A., Bossone, E., Scarafile, R., Riegler, L., Salvo, G. D., Gravino, R., Pezzullo, E., Limongelli, G., Romanò, M., et al. (2011) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0b013e328349a268 · Cited by 24
Prinz, C., van Buuren, F., Faber, L., Bitter, T., Bogunović, N., Burchert, W., & Horstkotte, D. (2011) · Echocardiography · doi:10.1111/j.1540-8175.2011.01588.x · Cited by 24
Haeck, M. L. A., Höke, U., Marsan, N. A., Holman, E. R., Wolterbeek, R., Bax, J. J., Schalij, M. J., Vliegen, H. W., & Delgado, V. (2014) · International journal of cardiac imaging · doi:10.1007/s10554-014-0384-1 · Cited by 23
Pavelescu, A., & Naeije, R. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-011-2085-y · Cited by 20
Cited by
Gorter, T. M., van Veldhuisen, D. J., Bauersachs, J., Borlaug, B. A., Celutkiene, J., Coats, A. J. S., Crespo-Leiro, M. G., Guazzi, M., Harjola, V.-P., Heymans, S., et al. (2018) · European Journal of Heart Failure · doi:10.1002/ejhf.1029 · Cited by 389
Self-citationMorris, D. A., Belyavskiy, E., Aravind-Kumar, R., Kropf, M., Frydas, A., Braunauer, K., Marquez, E., Krisper, M., Lindhorst, R., Osmanoglou, E., et al. (2018) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2017.07.029 · Cited by 388
Self-citation2- and 3-Dimensional Myocardial Strain in Cardiac Health and Disease
Voigt, J.-U., & Cvijic, M. (2019) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2019.01.044 · Cited by 333
Gorter, T. M., Hoendermis, E. S., van Veldhuisen, D. J., Voors, A. A., Lam, C. S. P., Geelhoed, B., Willems, T. P., & van Melle, J. P. (2016) · European Journal of Heart Failure · doi:10.1002/ejhf.630 · Cited by 300
Smiseth, O. A., Rider, O., Cvijic, M., Valkovič, L., Remme, E. W., & Voigt, J.-U. (2025) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2024.07.011 · Cited by 231
Metadata
- Authors
- Morris, D. A., Krisper, M., Nakatani, S., Köhncke, C., Otsuji, Y., Belyavskiy, E., Radha Krishnan, A. K., Kropf, M., Osmanoglou, E., Boldt, L.-H., Blaschke, F., Edelmann, F., Haverkamp, W., Tschöpe, C., Pieske-Kraigher, E., Pieske, B., & Takeuchi, M.
- Venue
- European Heart Journal – Cardiovascular Imaging
- Publisher
- Oxford University Press (OUP)
- Published
- 2016-02-11
- Volume
- 18
- Issue
- 2
- Pages
- 212-223
- ISSN
- 2047-2404 (ISSN-L)
- 2047-2412
- OpenAlex
- W2252944161
- Cited by
- 185
- References
- 30
- FWCI
- 10.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.