Impact of the 2016 ASE/EACVI recommendations on the prevalence of diastolic dysfunction in the general population
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Aims: Diastolic dysfunction (DD) is frequent in the general population; however, the assessment of diastolic function remains challenging. We aimed to evaluate the impact of the recent 2016 American Society of Echocardiography (ASE)/European Association of Cardiovascular Imaging (EACVI) recommendations in the prevalence and grades of DD compared with the 2009 guidelines and the Canberra Study Criteria (CSC). Methods and results: Within a population-based cohort, a total of 1000 individuals, aged ≥45 years, were evaluated retrospectively. Patients with previously known cardiac disease or ejection fraction <50% were excluded. Diastolic function was assessed by transthoracic echocardiography. DD prevalence and grades were determined according to the three classifications. The mean age was 62.0 ± 10.5 years and 37% were men. The prevalence of DD was 1.4% (n = 14) with the 2016 recommendations, 38.1% (n = 381) with the 2009 recommendations, and 30.4% (n = 304) using the CSC. The concordance between the updated recommendations and the other two was poor (from k = 0.13 to k = 0.18, P < 0.001). Regarding the categorization in DD grades, none of the 14 individuals with DD by the 2016 guidelines were assigned to Grade 1 DD, 64% were classified as Grade 2, 7% had Grade 3, and 29% had indeterminate grade. Conclusion: The application of the new 2016 ASE/EACVI recommendations resulted in a much lower prevalence of DD. The concordance between the classifications was poor. The updated algorithm seems to be able to diagnose only the most advanced cases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2016 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure
Ponikowski, P., Voors, A. A., Anker, S. D., Bueno, H., Cleland, J. G. F., Coats, A. J. S., Falk, V., González-Juanatey, J. R., Harjola, V.-P., Jankowska, E. A., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw128 · Cited by 11,429
Lang, R. M., Bierig, M., Devereux, R. B., Flachskampf, F. A., Foster, E., Pellikka, P. A., Picard, M. H., Roman, M. J., Seward, J., Shanewise, J. S., et al. (2005) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2005.10.005 · Cited by 11,318 · cited 1×
“Chamber quantification and function was assessed according the 2005 ASE/EAE recommendations.(12) Left atrial (LA) volume was measured at end-ventricular systole, avoiding foreshortening of the atrium, using apical views and Simpson’s rule.”
MethodSelf-citationRecommendations for the evaluation of left ventricular diastolic function by echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelisa, A. (2008) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep007 · Cited by 3,351 · cited 1×
“The first classification was based on the 2009 ASE/EAE recommendations for the evaluation of LV diastolic function.(7) This grading system suggests starting with e0 velocities and indexed LA volume.”
MethodSelf-citationObokata, M., Kane, G. C., Reddy, Y. N. V., Olson, T. P., Melenovsky, V., & Borlaug, B. A. (2017) · Circulation · doi:10.1161/circulationaha.116.024822 · Cited by 559 · cited 2×
“%) suggest that the newer algorithm and the inclusion of the TR parameter might have resulted in lower sensitivity and higher specificity to diagnose DD. Consistent with these observations, Obokata et al.21 showed that the new algorithm was specific but poorly sensitive, being able to identify only 34% of individuals…”
Result
Cited by
Updated Cardiovascular Prevention Guideline of the Brazilian Society of Cardiology - 2019
Précoma, D. B., Oliveira, G. M. M. D., Simão, A. F., Dutra, O. P., Coelho-Filho, O. R., Izar, M. C. D. O., Póvoa, R. M. D. S., Giuliano, I. D. C. B., Alencar Filho, A. C. D., Machado, C. A., et al. (2019) · Arquivos Brasileiros de Cardiologia · doi:10.5935/abc.20190204 · Cited by 434
Redefining Cirrhotic Cardiomyopathy for the Modern Era
Izzy, M., VanWagner, L. B., Lin, G., Altieri, M., Findlay, J. Y., Oh, J. K., Watt, K. D., Lee, S. S., & on behalf of The Cirrhotic Cardiomyopathy Consortium (2020) · Hepatology · doi:10.1002/hep.30875 · Cited by 367
Smiseth, O. A., Morris, D. A., Cardim, N., Cikes, M., Delgado, V., Donal, E., Flachskampf, F. A., Galderisi, M., Gerber, B. L., Gimelli, A., et al. (2022) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeab154 · Cited by 347
Self-citationArtificial Intelligence-Enabled ECG for Left Ventricular Diastolic Function and Filling Pressure
Lee, E., Ito, S., Miranda, W. R., Lopez-Jimenez, F., Kane, G. C., Asirvatham, S. J., Noseworthy, P. A., Friedman, P. A., Carter, R. E., Borlaug, B. A., et al. (2024) · npj Digital Medicine · doi:10.1038/s41746-023-00993-7 · Cited by 106
Metadata
- Authors
- Almeida, J. G., Fontes-Carvalho, R., Sampaio, F., Ribeiro, J., Bettencourt, P., Flachskampf, F. A., Leite-Moreira, A., & Azevedo, A.
- Venue
- European Heart Journal - Cardiovascular Imaging
- Publisher
- Oxford University Press (OUP)
- Published
- 2017-12-11
- Volume
- 19
- Issue
- 4
- Pages
- 380-386
- ISSN
- 2047-2404 (ISSN-L)
- 2047-2412
- OpenAlex
- W2773067288
- Cited by
- 169
- References
- 4
- FWCI
- 11.23
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.