Estimation of myocardial work from pressure–strain loops analysis: an experimental evaluation
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Purpose: The area of left ventricular (LV) pressure-strain loop (PSL) is used as an index of regional myocardial work. The purpose of the present work is to compare the main segmental PSL markers and the derived global work indices, when they are calculated using an estimated pressure signal or an observed pressure signal. Methods and results: In nine patients implanted with a bi-ventricular pace-maker (CRT), LV pressure was invasively measured in five conditions: CRT-off, LV-pacing, right ventricular-pacing and two different CRT-pacing. For each condition, systolic blood pressure was measured by brachial artery cuff-pressure and transthoracic echocardiography loops were recorded simultaneously. The error and relative root mean square error (rRMSE) between measured and estimated pressure were calculated for each patient and each configuration. Correlation coefficient (R2) and Bland-Altman (BA) analysis were performed for PSL area and work indices. A total of 43 different haemodynamic conditions were compared (774 segmental PSL). The global rRMSE between estimated and measured LV-pressure was 12.3 mmHg. The estimated and measured segmental LV-PSL were strongly correlated, with an R2 of 0.98. BA analysis shows that the mean bias for the estimation of segmental LV-PSL area is 86.0 mmHg.%. A significant bias effect with linearly increasing error with pressure values is observed. R2 ≥ 0.88 and a mean bias in BA analysis ≤41.4 mmHg.% was observed for the estimation of global myocardial work indices. Conclusion: The non-invasive estimation for LV pressure-strain loop area and the global myocardial work indices obtained from LV-PSL strongly correlates with invasive measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht150 · Cited by 2,809
Comparing methods of measurement: why plotting difference against standard method is misleading
Bland, J. M., & Altman, D. G. (1995) · The Lancet · doi:10.1016/s0140-6736(95)91748-9 · Cited by 2,343 · cited 1×
“these invasive and measured indices were compared using linear regression method(7) and Bland–Altman (BA) analysis.(10,11) Linear regression is a linear approach for modelling the relationship between an index variable and another independent variable, using linear predictor functions to model relationships.”
MethodRussell, K., Eriksen, M., Aaberge, L., Wilhelmsen, N., Skulstad, H., Remme, E. W., Haugaa, K. H., Opdahl, A., Fjeld, J. G., Gjesdal, O., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs016 · Cited by 865 · cited 9×
“As suggested by Russel et al.(5,7,9); valvular timings obtained from TTE are used to estimate a normalized, patient specific LV pressure curve.”
MethodInfluentialRussell, K., Eriksen, M., Aaberge, L., Wilhelmsen, N., Skulstad, H., Gjesdal, O., Edvardsen, T., & Smiseth, O. A. (2013) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00191.2013 · Cited by 336 · cited 10×
“As suggested by Russel et al.(5,7,9); valvular timings obtained from TTE are used to estimate a normalized, patient specific LV pressure curve.”
MethodInfluentialAvoiding non-responders to cardiac resynchronization therapy: a practical guide
Daubert, C., Behar, N., Martins, R. P., Mabo, P., & Leclercq, C. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw270 · Cited by 311
Self-citationStankovic, I., Prinz, C., Ciarka, A., Daraban, A. M., Kotrc, M., Aarones, M., Szulik, M., Winter, S., Belmans, A., Neskovic, A. N., et al. (2016) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jev288 · Cited by 215
Boe, E., Russell, K., Eek, C., Eriksen, M., Remme, E. W., Smiseth, O. A., & Skulstad, H. (2015) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jev078 · Cited by 215 · cited 5×
“As suggested by Russel et al.(5,7,9); valvular timings obtained from TTE are used to estimate a normalized, patient specific LV pressure curve.”
MethodInfluentialRole of myocardial constructive work in the identification of responders to CRT
Galli, E., Leclercq, C., Hubert, A., Bernard, A., Smiseth, O. A., Mabo, P., Samset, E., Hernandez, A. I., & Donal, E. (2017) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jex191 · Cited by 147 · cited 6×
“work, calculated from LV-PSL, may thus provide a new opportunity to better predict CRT-response.(8) However, the accuracy of this new tool, in different haemodynamic conditions, has not been verified.”
BackgroundMethodSelf-citationVečeřa, J., Pěnička, M., Eriksen, M., Russell, K. E., Bartunek, J., Vanderheyden, M., & Smiseth, O. A. (2016) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jew019 · Cited by 145 · cited 3×
“Galli E, Leclercq C, Hubert A, Bernard A, Smiseth OA, Mabo P et al. Role of myocardial constructive work in the identification of responders to CRT. Eur Heart J Cardiovasc Imaging 2017 Aug 7 [Epub ahead of print], doi:10.1093/ehjci/jex191.”
BackgroundInfluential
Cited by
Chan, J., Edwards, N. F. A., Khandheria, B. K., Shiino, K., Sabapathy, S., Anderson, B., Chamberlain, R., & Scalia, G. M. (2019) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jey131 · Cited by 346
Edwards, N. F. A., Scalia, G. M., Shiino, K., Sabapathy, S., Anderson, B., Chamberlain, R., Khandheria, B. K., & Chan, J. (2019) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2019.02.014 · Cited by 245
“LV myocardial strain is a load-dependent variable influenced by alterations in loading conditions.(12,14,15) Ameta-analysis of 24 studies by Yingchoncharoen et al.”
BackgroundMethodHow to measure left ventricular myocardial work by pressure–strain loops
Smiseth, O. A., Donal, E., Penicka, M., & Sletten, O. J. (2021) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeaa301 · Cited by 130
Self-citationMinhas, A. S., Gilotra, N. A., Goerlich, E., Metkus, T., Garibaldi, B. T., Sharma, G., Bavaro, N., Phillip, S., Michos, E. D., & Hays, A. G. (2021) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2021.667721 · Cited by 34
Metadata
- Authors
- Hubert, A., Le Rolle, V., Leclercq, C., Galli, E., Samset, E., Casset, C., Mabo, P., Hernandez, A., & Donal, E.
- Venue
- European Heart Journal - Cardiovascular Imaging
- Publisher
- Oxford University Press (OUP)
- Published
- 2018-02-26
- Volume
- 19
- Issue
- 12
- Pages
- 1372-1379
- ISSN
- 2047-2404 (ISSN-L)
- 2047-2412
- OpenAlex
- W2794331413
- Cited by
- 220
- References
- 20
- FWCI
- 13.59
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.