CoChat

Relationship between changes in pericoronary adipose tissue attenuation and coronary plaque burden quantified from coronary computed tomography angiography

Open access
Goeller, Markus, Tamarappoo, Balaji K, Kwan, Alan C, Cadet, Sebastien, Commandeur, Frederic, Razipour, Aryabod, Slomka, Piotr J, Gransar, Heidi, Chen, Xi, Otaki, Yuka, Friedman, John D, Cao, J Jane, Albrecht, Moritz H, Bittner, Daniel O, Marwan, Mohamed, Achenbach, Stephan, Berman, Daniel S, Dey, Damini · 2019 · European Heart Journal - Cardiovascular Imaging
Cited by 243

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Aims: Increased attenuation of pericoronary adipose tissue (PCAT) around the proximal right coronary artery (RCA) from coronary computed tomography angiography (CTA) has been shown to be associated with coronary inflammation and improved prediction of cardiac death over plaque features. Our aim was to investigate whether PCAT CT attenuation is related to progression of coronary plaque burden. Methods and results: We analysed CTA studies of 111 stable patients (age 59.2 ± 9.8 years, 77% male) who underwent sequential CTA (3.4 ± 1.6 years between scans) with identical acquisition protocols. Total plaque (TP), calcified plaque (CP), non-calcified plaque (NCP), and low-density non-calcified plaque (LD-NCP) volumes and corresponding burden (plaque volume × 100%/vessel volume) were quantified using semi-automated software. PCAT CT attenuation (HU) was measured around the proximal RCA, the most standardized method for PCAT analysis. Patients with an increase in NCP burden (n = 51) showed an increase in PCAT attenuation, whereas patients with a decrease in NCP burden (n = 60) showed a decrease {4.4 [95% confidence interval (CI) 2.6–6.2] vs. −2.78 (95% CI −4.6 to −1.0) HU, P < 0.0001}. Changes in PCAT attenuation correlated with changes in the burden of NCP (r = 0.55, P < 0.001) and LD-NCP (r = 0.24, P = 0.01); but not CP burden (P = 0.3). Increased baseline PCAT attenuation ≥−75 HU was independently associated with increase in NCP (odds ratio 3.07, 95% CI 1.4–7.0; P < 0.008) and TP burden on follow-up CTA. Conclusion: PCAT attenuation measured from routine CTA is related to the progression of NCP and TP burden. This imaging biomarker may help to identify patients at increased risk of high-risk plaque progression and allow monitoring of beneficial changes from medical therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ehjci/jez013

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 243

Metadata

Authors
Goeller, M., Tamarappoo, B. K., Kwan, A. C., Cadet, S., Commandeur, F., Razipour, A., Slomka, P. J., Gransar, H., Chen, X., Otaki, Y., Friedman, J. D., Cao, J. J., Albrecht, M. H., Bittner, D. O., Marwan, M., Achenbach, S., Berman, D. S., & Dey, D.
Venue
European Heart Journal - Cardiovascular Imaging
Published
2019-02-13
Volume
20
Issue
6
Pages
636-643
ISSN
  • 2047-2404 (ISSN-L)
  • 2047-2412
OpenAlex
W2915032895
Cited by
243
References
3
FWCI
13.69
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.