ECG-AI: electrocardiographic artificial intelligence model for prediction of heart failure
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Aims: Heart failure (HF) is a leading cause of death. Early intervention is the key to reduce HF-related morbidity and mortality. This study assesses the utility of electrocardiograms (ECGs) in HF risk prediction. Methods and results: Data from the baseline visits (1987–89) of the Atherosclerosis Risk in Communities (ARIC) study was used. Incident hospitalized HF events were ascertained by ICD codes. Participants with good quality baseline ECGs were included. Participants with prevalent HF were excluded. ECG-artificial intelligence (AI) model to predict HF was created as a deep residual convolutional neural network (CNN) utilizing standard 12-lead ECG. The area under the receiver operating characteristic curve (AUC) was used to evaluate prediction models including (CNN), light gradient boosting machines (LGBM), and Cox proportional hazards regression. A total of 14 613 (45% male, 73% of white, mean age ± standard deviation of 54 ± 5) participants were eligible. A total of 803 (5.5%) participants developed HF within 10 years from baseline. Convolutional neural network utilizing solely ECG achieved an AUC of 0.756 (0.717–0.795) on the hold-out test data. ARIC and Framingham Heart Study (FHS) HF risk calculators yielded AUC of 0.802 (0.750–0.850) and 0.780 (0.740–0.830). The highest AUC of 0.818 (0.778–0.859) was obtained when ECG-AI model output, age, gender, race, body mass index, smoking status, prevalent coronary heart disease, diabetes mellitus, systolic blood pressure, and heart rate were used as predictors of HF within LGBM. The ECG-AI model output was the most important predictor of HF. Conclusions: ECG-AI model based solely on information extracted from ECG independently predicts HF with accuracy comparable to existing FHS and ARIC risk calculators.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
Heart Disease and Stroke Statistics—2019 Update: A Report From the American Heart Association
Benjamin, E. J., Muntner, P., Alonso, A., Bittencourt, M. S., Callaway, C. W., Carson, A. P., Chamberlain, A. M., Chang, A. R., Cheng, S., Das, S. R., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000659 · Cited by 9,036
Prediction of mortality from 12-lead electrocardiogram voltage data using a deep neural network
Raghunath, S., Ulloa Cerna, A. E., Jing, L., vanMaanen, D. P., Stough, J., Hartzel, D. N., Leader, J. B., Kirchner, H. L., Stumpe, M. C., Hafez, A., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0870-z · Cited by 314 · cited 1×
“cardiomyopathy,(10,11) and all-cause mortality.(12) We hypothesize that”
Artificial Intelligence for the Diagnosis of Heart Failure
Choi, D.-J., Park, J. J., Ali, T., & Lee, S. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0261-3 · Cited by 163
Cited by
Manickam, P., Mariappan, S. A., Murugesan, S. M., Hansda, S., Kaushik, A., Shinde, R., & Thipperudraswamy, S. P. (2022) · Biosensors · doi:10.3390/bios12080562 · Cited by 637
Predicting Heart Failure From 12-Lead ECGs Using AI
Desai, A. S., Pandey, A., Suratekar, R., Ahmad, F. S., Alger, H. M., Anto, A. G., Nujum G, S., Lopez-Jimenez, F., Oh, J. K., Asfahan, S., et al. (2026) · JACC · doi:10.1016/j.jacc.2025.10.065 · Cited by 16
Palantzas, A., & Anagnostouli, M. (2025) · International Journal of Molecular Sciences · doi:10.3390/ijms26178217 · Cited by 11
Artificial Intelligence-Enabled ECG Analysis to Predict Incident Heart Failure
Khurshid, S., Friedman, S. F., Kany, S., D’Souza, V., Roshandelpoor, A., Kosyakovsky, L. B., Chitsazan, M., Cunningham, J. W., Singh, P., Lau, E. S., et al. (2026) · Circulation: Heart Failure · doi:10.1161/circheartfailure.125.013927 · Cited by 2
Metadata
- Authors
- Akbilgic, O., Butler, L., Karabayir, I., Chang, P. P., Kitzman, D. W., Alonso, A., Chen, L. Y., & Soliman, E. Z.
- Venue
- European Heart Journal - Digital Health
- Publisher
- Oxford University Press (OUP)
- Published
- 2021-10-09
- Volume
- 2
- Issue
- 4
- Pages
- 626-634
- ISSN
- 2634-3916 (ISSN-L)
- OpenAlex
- W3206143748
- Cited by
- 115
- References
- 4
- FWCI
- 8.40
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ECG-AI: electrocardiographic artificial intelligence model for prediction of heart failure. https://app.cochat.ai/papers/10.1093/ehjdh/ztab080
- The paper
- Akbilgic, O., Butler, L., Karabayir, I., Chang, P. P., Kitzman, D. W., Alonso, A., Chen, L. Y., & Soliman, E. Z. (2021). ECG-AI: electrocardiographic artificial intelligence model for prediction of heart failure. European Heart Journal - Digital Health. https://doi.org/10.1093/ehjdh/ztab080
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.