Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 717

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Stress echocardiography expert consensus statement: European Association of Echocardiography (EAE) (a registered branch of the ESC)

Open access
Sicari, R., Nihoyannopoulos, P., Evangelista, A., Kasprzak, J., Lancellotti, P., Poldermans, D., Voigt, J.-U., Zamorano, J. L., on behalf of the European Association of Echocardiography·2008·European Journal of Echocardiography

Abstract

Stress echocardiography is the combination of 2D echocardiography with a physical, pharmacological or electrical stress. The diagnostic end point for the detection of myocardial ischemia is the induction of a transient worsening in regional function during stress. Stress echocardiography provides similar diagnostic and prognostic accuracy as radionuclide stress perfusion imaging, but at a substantially lower cost, without environmental impact, and with no biohazards for the patient and the physician. Among different stresses of comparable diagnostic and prognostic accuracy, semisupine exercise is the most used, dobutamine the best test for viability, and dipyridamole the safest and simplest pharmacological stress and the most suitable for combined wall motion coronary flow reserve assessment. The additional clinical benefit of myocardial perfusion contrast echocardiography and myocardial velocity imaging has been inconsistent to date, whereas the potential of adding - coronary flow reserve evaluation of left anterior descending coronary artery by transthoracic Doppler echocardiography adds another potentially important dimension to stress echocardiography. New emerging fields of application taking advantage from the versatility of the technique are Doppler stress echo in valvular heart disease and in dilated cardiomyopathy. In spite of its dependence upon operator's training, stress echocardiography is today the best (most cost-effective and risk-effective) possible imaging choice to achieve the still elusive target of sustainable cardiac imaging in the field of noninvasive diagnosis of coronary artery disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ejechocard/jen175

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 717

Metadata

Authors
Sicari, R., Nihoyannopoulos, P., Evangelista, A., Kasprzak, J., Lancellotti, P., Poldermans, D., Voigt, J.-U., Zamorano, J. L., & on behalf of the European Association of Echocardiography
Venue
European Journal of Echocardiography
Published
2008-02-19
Volume
9
Issue
4
Pages
415-437
ISSN
  • 1525-2167 (ISSN-L)
  • 1532-2114
OpenAlex
W2131195601
Cited by
717
References
1
FWCI
37.99
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Stress echocardiography expert consensus statement: European Association of Echocardiography (EAE) (a registered branch of the ESC). https://app.cochat.ai/papers/10.1093/ejechocard/jen175
The paper
Sicari, R., Nihoyannopoulos, P., Evangelista, A., Kasprzak, J., Lancellotti, P., Poldermans, D., Voigt, J.-U., Zamorano, J. L., & on behalf of the European Association of Echocardiography. (2008). Stress echocardiography expert consensus statement: European Association of Echocardiography (EAE) (a registered branch of the ESC). European Journal of Echocardiography. https://doi.org/10.1093/ejechocard/jen175

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.