CoChat

Predicting left ventricular dysfunction after valve repair for mitral regurgitation due to leaflet prolapse: additive value of left ventricular end-systolic dimension to ejection fraction

Tribouilloy, C., Rusinaru, D., Szymanski, C., Mezghani, S., Fournier, A., Levy, F., Peltier, M., Ben Ammar, A., Carmi, D., Remadi, J.-P., Caus, T., Touati, G. · 2011 · European Journal of Echocardiography
Cited by 95

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

AIMS: Left ventricular (LV) dysfunction is the first cause of late mortality after mitral valve surgery. In this retrospective analysis, we studied the association between preoperative echocardiographic LV measures and occurrence of LV dysfunction after mitral valve repair (MVR). METHODS AND RESULTS: Between 1991 and 2009, 335 consecutive patients underwent MVR for severe mitral regurgitation due to leaflet prolapse in our institution. Echocardiography was performed preoperatively and at 10.8 (9.1-12.0) months after surgery in 303 patients who represented the study population. Cardiac events were recorded during follow-up. LV ejection fraction (EF) decreased from 68 ± 9% before surgery to 59 ± 9% post-operatively (P < 0.001). Preoperative EF <64% and LV end-systolic diameter (ESD) ≥ 37 mm were the best cut-off values for the prediction of post-operative LV dysfunction (EF < 50%). On the basis of a combined analysis, the occurrence of post-operative LV dysfunction was 9% when EF was ≥ 64% and LVESD < 37 mm, 21% with EF < 64% or LVESD ≥ 37 mm, and 33% with EF < 64% and LVESD ≥ 37 mm (P for trend < 0.001). The combined variable EF < 64% and LVESD ≥ 37 mm added incremental prognostic value to the multivariable regression model (P = 0.001). CONCLUSION: Simple preoperative echocardiography measures allow the prediction of LV dysfunction after MVR in patients with leaflet prolapse. Patients with preoperative EF ≥ 64% and LVESD < 37 mm incur relatively low risk of post-operative LV dysfunction.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ejechocard/jer128

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Tribouilloy, C., Rusinaru, D., Szymanski, C., Mezghani, S., Fournier, A., Levy, F., Peltier, M., Ben Ammar, A., Carmi, D., Remadi, J.-P., Caus, T., & Touati, G.
Venue
European Journal of Echocardiography
Published
2011-08-04
Volume
12
Issue
9
Pages
702-710
ISSN
  • 1525-2167 (ISSN-L)
  • 1532-2114
OpenAlex
W2108825966
Cited by
95
References
1
FWCI
3.49
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.