CoChat

Adverse effect of right ventricular pacing prevented by biventricular pacing during long-term follow-up: a randomized comparison

Albertsen, A. E., Mortensen, P. T., Jensen, H. K., Poulsen, S. H., Egeblad, H., Nielsen, J. C. · 2011 · European Journal of Echocardiography
Cited by 43

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

AIMS: To investigate whether biventricular (BIV) pacing preserves left ventricular ejection fraction (LVEF) and reduces LV dyssynchrony when compared with standard dual-chamber right ventricular (RV) pacing in consecutive patients with high-grade atrioventricular block during 3 years of pacing. METHODS AND RESULTS: Fifty patients were randomized to RV pacing or BIV pacing. LVEF was measured using three-dimensional echocardiography. Tissue Doppler imaging was used to quantify LV dyssynchrony in terms of the standard deviation of the time-to-peak velocity (Ts-SD). LVEF differed significantly between the two groups during 3 years of pacing (ANOVA: P=0.003). LVEF in the RV group decreased from 59±5% at baseline to 53±11% (P=0.01), while LVEF remained unchanged in the BIV group (57±7% at baseline vs. 58±10% (P=0.40). After 3 years of follow-up, we observed no difference in LV dyssynchrony, LV remodelling or measurements of clinical heart failure (N-terminal pro-brain natriuretic peptide, walking test, and New York Heart Association functional class) between the two groups. However, in the RV group, but not in the BIV group, dyssynchrony increased significantly (P=0.005) during follow-up. Furthermore, adverse LV remodelling was observed in the RV group with increased systolic volume and thinning of the LV septum. CONCLUSION: BIV pacing preserves LVEF and minimizes LV dyssynchrony during long-term follow-up. Adverse remodelling observed during 3 years of RV pacing was prevented by BIV pacing. However, the adverse impact of RV pacing on LV function was not reflected in measures of clinical heart failure. CLINICAL TRIAL REGISTRATION: www.clinicaltrials.gov (identification number: NCT00228241).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ejechocard/jer136

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Albertsen, A. E., Mortensen, P. T., Jensen, H. K., Poulsen, S. H., Egeblad, H., & Nielsen, J. C.
Venue
European Journal of Echocardiography
Published
2011-08-20
Volume
12
Issue
10
Pages
767-772
ISSN
  • 1525-2167 (ISSN-L)
  • 1532-2114
OpenAlex
W2134920553
Cited by
43
References
4
FWCI
1.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.