CoChat

Assessment of the American Society of Echocardiography-European Association of Echocardiography guidelines for diastolic function in patients with depressed ejection fraction: an echocardiographic and invasive haemodynamic study

Dokainish, H., Nguyen, J. S., Bobek, J., Goswami, R., Lakkis, N. M. · 2011 · European Journal of Echocardiography
Cited by 76

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

AIMS: There is controversy surrounding the accuracy of echo-Doppler variables, including early mitral inflow/mitral annular velocity (E/e'), for estimating left ventricular filling pressure (LVFP) in patients with depressed ejection fraction (EF < 50%). METHODS AND RESULTS: The American Society of Echocardiography-European Association of Echocardiography (ASE-EAE) algorithm for diastolic function in depressed LVEF was retrospectively applied to a database of patients who underwent echocardiography ≤20 min of cardiac catheterization. LV pre-atrial contraction pressure (pre-A) ≥15 mmHg was elevated. Of 62 patients studied, the mean age was 53.6 ± 10.6 years and the mean LVEF was 27.2 ± 11.8%. The correlations of E/e' (R = 0.43, P = 0.0005) and E (R = 0.39, P = 0.002) with LV pre-A were modest, compared with pulmonary artery pressure (PAP, R = 0.69, P = 0.0006), E/late mitral (A) velocity (R = 0.52, P < 0.0001), and mitral deceleration time (DT, R = -0.51, P < 0.0001). Using the ASE-ESE algorithm starting with E/A, E, and DT, 54 of 62 patients were accurately classified to predict LV pre-A >15 or <15 mmHg (sensitivity = 84%, specificity = 80%, area under the curve = 0.86, P < 0.001). The 6 of 6 patients with E/A < 1 and E < 50 and the 14 of 15 (93%) patients with E/A> 2 and DT < 150 were correctly classified as having normal and elevated LVFP, respectively, while 34 of 41 (83%) patients with E/A = 1-2 or E/A<1 and E>50 cm/s were correctly classified using the addition of E/e' and PAP. CONCLUSION: This retrospective study shows that in this population with depressed LVEF, no single echo-Doppler variable had high accuracy for predicting LV pre-A ≥15 mmHg. However, the ASE-EAE algorithm using multiple variables predicted LVFP with good accuracy, superior to any single echo-Doppler variable alone.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ejechocard/jer157

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 76

Metadata

Authors
Dokainish, H., Nguyen, J. S., Bobek, J., Goswami, R., & Lakkis, N. M.
Venue
European Journal of Echocardiography
Published
2011-09-01
Volume
12
Issue
11
Pages
857-864
ISSN
  • 1525-2167 (ISSN-L)
  • 1532-2114
OpenAlex
W2126277107
Cited by
76
References
4
FWCI
3.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of the American Society of Echocardiography-European Association of Echocardiography guidelines for diastolic function in patients with depressed ejection fraction: an echocardiographic and invasive haemodynamic study. https://app.cochat.ai/papers/10.1093/ejechocard/jer157
The paper
Dokainish, H., Nguyen, J. S., Bobek, J., Goswami, R., & Lakkis, N. M. (2011). Assessment of the American Society of Echocardiography-European Association of Echocardiography guidelines for diastolic function in patients with depressed ejection fraction: an echocardiographic and invasive haemodynamic study. European Journal of Echocardiography. https://doi.org/10.1093/ejechocard/jer157

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.