Abstract

The objective of this study was to compare glass fibre reinforced (GFR) with multistranded bonded orthodontic retainers in terms of success rate and periodontal implications. A 2 year parallel study was conducted of 184 patients scheduled to receive bonded retainers in the upper and lower anterior segments. In three centres, the patients (mean age 14 years; 90 males and 94 females) were sequentially assigned to receive GFR retainers containing 500 unidirectional glass fibres (GFR500), 1000 unidirectional glass fibres (GFR1000), or multistranded retainers (gold standard). Retainer failures and periodontal conditions were monitored every 6 months. In a control group of 90 subjects without retainers, periodontal conditions were examined (negative control). Of the 274 recruited patients, 15 dropped out during the 2 year study period. Kaplan-Meier plots were drawn to assess survival of the different retainers. The Mantel-Cox log-rank test was used to identify significant differences in survival functions among the groups. Repeated measures analysis of variance and appropriate post hoc tests were adopted to evaluate periodontal conditions over time. GFR retainers showed unacceptably high failure rates in comparison with multistranded retainers (51 versus 12 per cent). The most significant periodontal conditions were found in patients with GFR retainers with no significant differences between the GFR500 and the GFR1000 group for any parameter at any time point. Subjects without retainers showed significantly lower levels of gingival inflammation and plaque accumulation when compared with patients in any retainer group. Multistranded retainers should remain the gold standard for orthodontic retention, although periodontal complications are common. The use of GFR retainers should be discouraged in daily practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ejo/cjp100

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 102

Metadata

Authors
Tacken, M. P. E., Cosyn, J., De Wilde, P., Aerts, J., Govaerts, E., & Vannet, B. V.
Venue
The European Journal of Orthodontics
Published
2009-10-16
Volume
32
Issue
2
Pages
117-123
ISSN
  • 0141-5387 (ISSN-L)
  • 1460-2210
OpenAlex
W2111091107
Cited by
102
References
6
FWCI
2.43
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Glass fibre reinforced versus multistranded bonded orthodontic retainers: a 2 year prospective multi-centre study. https://app.cochat.ai/papers/10.1093/ejo/cjp100
The paper
Tacken, M. P. E., Cosyn, J., De Wilde, P., Aerts, J., Govaerts, E., & Vannet, B. V. (2010). Glass fibre reinforced versus multistranded bonded orthodontic retainers: a 2 year prospective multi-centre study. The European Journal of Orthodontics. https://doi.org/10.1093/ejo/cjp100

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.