Abstract

Aims: To evaluate the safety and efficacy of left atrial appendage occlusion (LAAO) with the Amplatzer™ Amulet™ occluder. Methods and results: Patients with atrial fibrillation eligible for LAAO were recruited to a prospective global study. Implant procedures were undertaken with echocardiographic guidance. Transoesophageal echocardiography (TOE) was undertaken 1–3 months post-LAAO. Implant and follow-up TOEs were evaluated by a CoreLab. The primary endpoint was a composite of ischaemic stroke and cardiovascular death at 2 years. Serious adverse events were adjudicated by an independent clinical events committee. A total of 1088 patients were enrolled, aged 75.2 ± 8.5 years; 64.5% were male. CHA2DS2-VASc and HAS-BLED scores were 4.2 ± 1.6 and 3.3 ± 1.1, respectively. A total of 71.7% had prior major bleeding, and 82.8% had contraindications to oral anticoagulants. Implant success was 99.1%. Major adverse events (≤7 days post-procedure) occurred in 4.0%, including death (0.3%), stroke (0.4%), major vascular (1.3%), and device embolization (0.2%). A total of 80.2% of patients were discharged on antiplatelet therapy alone. Peridevice flow was <3 mm in 98.4% at follow-up TOE. Device-related thrombus (DRT) was seen in 1.6% of cases. Cardiovascular death or ischaemic stroke occurred in 8.7% of patients at 2 years. The ischaemic stroke rate was 2.2%/year—a 67% reduction compared to the CHA2DS2-VASc predicted rate. Major bleeding (Bleeding Academic Research Consortium type ≥ 3) occurred at rates of 10.1%/year (year 1) and 4.0%/year (year 2). Conclusion: Following LAAO with the Amplatzer Amulet device, the ischaemic stroke rate was reduced by 67% compared to the predicted risk. Closure was complete in 98.4% of cases and DRT seen in only 1.6%.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehaa169

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 171

Metadata

Authors
Hildick-Smith, D., Landmesser, U., Camm, A. J., Diener, H.-C., Paul, V., Schmidt, B., Settergren, M., Teiger, E., Nielsen-Kudsk, J. E., & Tondo, C.
Venue
European Heart Journal
Published
2020-04-03
Volume
41
Issue
30
Pages
2894-2901
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W3014781735
Cited by
171
References
3
FWCI
14.66
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Left atrial appendage occlusion with the Amplatzer™ Amulet™ device: full results of the prospective global observational study. https://app.cochat.ai/papers/10.1093/eurheartj/ehaa169
The paper
Hildick-Smith, D., Landmesser, U., Camm, A. J., Diener, H.-C., Paul, V., Schmidt, B., Settergren, M., Teiger, E., Nielsen-Kudsk, J. E., & Tondo, C. (2020). Left atrial appendage occlusion with the Amplatzer™ Amulet™ device: full results of the prospective global observational study. European Heart Journal. https://doi.org/10.1093/eurheartj/ehaa169

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.