Left atrial appendage occlusion with the Amplatzer™ Amulet™ device: full results of the prospective global observational study
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Aims: To evaluate the safety and efficacy of left atrial appendage occlusion (LAAO) with the Amplatzer™ Amulet™ occluder. Methods and results: Patients with atrial fibrillation eligible for LAAO were recruited to a prospective global study. Implant procedures were undertaken with echocardiographic guidance. Transoesophageal echocardiography (TOE) was undertaken 1–3 months post-LAAO. Implant and follow-up TOEs were evaluated by a CoreLab. The primary endpoint was a composite of ischaemic stroke and cardiovascular death at 2 years. Serious adverse events were adjudicated by an independent clinical events committee. A total of 1088 patients were enrolled, aged 75.2 ± 8.5 years; 64.5% were male. CHA2DS2-VASc and HAS-BLED scores were 4.2 ± 1.6 and 3.3 ± 1.1, respectively. A total of 71.7% had prior major bleeding, and 82.8% had contraindications to oral anticoagulants. Implant success was 99.1%. Major adverse events (≤7 days post-procedure) occurred in 4.0%, including death (0.3%), stroke (0.4%), major vascular (1.3%), and device embolization (0.2%). A total of 80.2% of patients were discharged on antiplatelet therapy alone. Peridevice flow was <3 mm in 98.4% at follow-up TOE. Device-related thrombus (DRT) was seen in 1.6% of cases. Cardiovascular death or ischaemic stroke occurred in 8.7% of patients at 2 years. The ischaemic stroke rate was 2.2%/year—a 67% reduction compared to the CHA2DS2-VASc predicted rate. Major bleeding (Bleeding Academic Research Consortium type ≥ 3) occurred at rates of 10.1%/year (year 1) and 4.0%/year (year 2). Conclusion: Following LAAO with the Amplatzer Amulet device, the ischaemic stroke rate was reduced by 67% compared to the predicted risk. Closure was complete in 98.4% of cases and DRT seen in only 1.6%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · Europace · doi:10.1093/europace/euw295 · Cited by 6,439
Self-citation2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw210 · Cited by 6,418
Self-citationRuff, C. T., Giugliano, R. P., Braunwald, E., Hoffman, E. B., Deenadayalu, N., Ezekowitz, M. D., Camm, A. J., Weitz, J. I., Lewis, B. S., Parkhomenko, A., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(13)62343-0 · Cited by 5,051 · cited 1×
“The use of oral anticoagulants (OAC) to prevent thromboembolism in patients with AF has a Class I recommendation in international guidelines,(2,5) with direct or novel OAC widely used in the prevention of AF-related stroke.(6) However, a portion of AF patients at high risk for stroke are not suitable for long-term OAC…”
BackgroundHolmes, D. R., Reddy, V. Y., Turi, Z. G., Doshi, S. K., Sievert, H., Buchbinder, M., Mullin, C. M., & Sick, P. (2009) · The Lancet · doi:10.1016/s0140-6736(09)61343-x · Cited by 2,240
January, C. T., Wann, L. S., Calkins, H., Chen, L. Y., Cigarroa, J. E., Cleveland, J. C., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., Furie, K. L., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.01.011 · Cited by 2,205
Holmes, D. R., Kar, S., Price, M. J., Whisenant, B., Sievert, H., Doshi, S. K., Huber, K., & Reddy, V. Y. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.04.029 · Cited by 1,845
Krijthe, B. P., Kunst, A., Benjamin, E. J., Lip, G. Y. H., Franco, O. H., Hofman, A., Witteman, J. C. M., Stricker, B. H., & Heeringa, J. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht280 · Cited by 1,419 · cited 1×
“There will be 13 million adults with AF in the European Union by 2030.(1) It is estimated that 10–40% of AF patients are hospitalized each year.”
BackgroundStroke Severity in Atrial Fibrillation: The Framingham Study
Lin, H.-J., Wolf, P. A., Kelly-Hayes, M., Beiser, A. S., Kase, C. S., Benjamin, E. J., & D'Agostino, R. B. (1996) · Stroke · doi:10.1161/01.str.27.10.1760 · Cited by 1,389
Friberg, L., Rosenqvist, M., & Lip, G. Y. H. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehr488 · Cited by 1,192 · cited 1×
“7%/year rate of major bleeding while on warfarin.(13,14)”
BackgroundLip, G. Y. H., Frison, L., Halperin, J. L., & Lane, D. A. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.09.024 · Cited by 1,080 · cited 1×
“7%/year rate of major bleeding while on warfarin.(13,14)”
BackgroundAtrial fibrillation: Profile and burden of an evolving epidemic in the 21st century
Ball, J., Carrington, M. J., McMurray, J. J. V., & Stewart, S. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.12.093 · Cited by 630
Tzikas, A., Shakir, S., Gafoor, S., Omran, H., Berti, S., Santoro, G., Kefer, J., Landmesser, U., Nielsen-Kudsk, J. E., Cruz-Gonzalez, I., et al. (2016) · EuroIntervention · doi:10.4244/eijy15m01_06 · Cited by 546 · cited 2×
“The 1st generation Amplatzer LAAO occluder, the Amplatzer Cardiac Plug, was evaluated in a retrospective registry, with good safety and efficacy.(10) The Amulet Observational Study prospectively enrolled patients prior to implant attempt with the Amulet occluder—the 2nd generation Amplatzer LAAO device.”
BackgroundMethodSelf-citationDevice-Related Thrombus After Left Atrial Appendage Closure: Incidence, Predictors, and Outcomes
Dukkipati, S. R., Kar, S., Holmes, D. R., Doshi, S. K., Swarup, V., Gibson, D. N., Maini, B., Gordon, N. T., Main, M. L., & Reddy, V. Y. (2018) · Circulation · doi:10.1161/circulationaha.118.035090 · Cited by 451
Boersma, L. V., Ince, H., Kische, S., Pokushalov, E., Schmitz, T., Schmidt, B., Gori, T., Meincke, F., Protopopov, A. V., Betts, T., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.038 · Cited by 433
Self-citationLandmesser, U., Schmidt, B., Nielsen‐Kudsk, J. E., Lam, S. C. C., Park, J., Tarantini, G., Cruz‐González, I., Geist, V., Bella, P. E. D., Colombo, A., et al. (2017) · EuroIntervention · doi:10.4244/eij-d-17-00493 · Cited by 192 · cited 3×
“Periprocedural outcomes of the Amulet Observational Study were previously detailed.(11) In this study, among a diverse group of implanters, ranging from 1 to 54 (median 8) enrolments per operator, a high degree of technical success (1078 of 1088 attempts; 99.”
BackgroundMethodSelf-citationKorsholm, K., Nielsen, K. M., Jensen, J. M., Jensen, H. K., Andersen, G., & Nielsen‐Kudsk, J. E. (2017) · EuroIntervention · doi:10.4244/eij-d-16-00726 · Cited by 131
Self-citationAminian, A., Schmidt, B., Mazzone, P., Berti, S. L., Fischer, S., Montorfano, M., Lam, S. C. C., Lund, J., Asch, F. M., Gage, R., et al. (2019) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2019.02.003 · Cited by 109 · cited 4×
“01).(15) A similar association between the presence of DRT and an increased rate of clinical events has been reported in patients implanted with the WATCHMAN device.”
BackgroundInfluentialSelf-citationLeft atrial appendage closure using AMPLATZER™ devices: A large, multicenter, Italian registry
Berti, S. L., Santoro, G., Brscic, E., Montorfano, M., Vignali, L., Danna, P., Tondo, C., D’Amico, G., Stabile, A., Saccà, S., et al. (2017) · International Journal of Cardiology · doi:10.1016/j.ijcard.2017.07.052 · Cited by 65
Self-citationLong-term Event Reduction After Left Atrial Appendage Closure. Results of the Iberian Registry II
López-Mínguez, J. R., Nogales‐Asensio, J. M., de Oliveira, E. I., Ribeiro, V. G., Ruiz-Salmeron, R. J., Arzamendi, D., Costa, M. A. D. S., Gutiérrez-García, H., Díaz, J. A. F., Martín‐Yuste, V., et al. (2018) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2018.03.017 · Cited by 34 · cited 1×
“2%/year.(20) A history of gastrointestinal bleeding was the main predictor of gastrointestinal bleeding following LAAO in the Iberian Registry (hazard ratio 4.”
BackgroundAtrial fibrillation and the 'other drug problem': reducing non-adherence with technology
Nerini, E., Grip, L. T., Camm, A. J., & Giugliano, R. P. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht174 · Cited by 9
Self-citation
Cited by
Van Gelder, I. C., Rienstra, M., Bunting, K. V., Casado-Arroyo, R., Caso, V., Crijns, H. J. G. M., De Potter, T. J. R., Dwight, J., Guasti, L., Hanke, T., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae176 · Cited by 3,024
Osmancik, P., Herman, D., Neuzil, P., Hala, P., Taborsky, M., Kala, P., Poloczek, M., Stasek, J., Haman, L., Branny, M., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.10.023 · Cited by 307
Atrial fibrillation and stroke prevention: 25 years of research at EP Europace journal
Lip, G. Y. H., Proietti, M., Potpara, T., Mansour, M., Savelieva, I., Tse, H. F., Goette, A., Camm, A. J., Blomstrom-Lundqvist, C., Gupta, D., et al. (2023) · Europace · doi:10.1093/europace/euad226 · Cited by 164
Self-citation
Metadata
- Authors
- Hildick-Smith, D., Landmesser, U., Camm, A. J., Diener, H.-C., Paul, V., Schmidt, B., Settergren, M., Teiger, E., Nielsen-Kudsk, J. E., & Tondo, C.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2020-04-03
- Volume
- 41
- Issue
- 30
- Pages
- 2894-2901
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W3014781735
- Cited by
- 171
- References
- 20
- FWCI
- 14.66
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.