CoChat

A trial of self-adhesive patch electrodes and hand-held paddle electrodes for external cardioversion of atrial fibrillation (MOBIPAPA)

Kirchhof, Paulus, Mönnig, Gerold, Wasmer, Kristina, Heinecke, Achim, Breithardt, Günter, Eckardt, Lars, Böcker, Dirk · 2005 · European Heart Journal
Cited by 93

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

AIMS: External electrical cardioversion is the method of choice to terminate persistent atrial fibrillation. Whether the type of shock electrode affects cardioversion success is not known. We tested whether hand-held steel electrodes improve cardioversion outcome with monophasic or biphasic shocks when compared with adhesive patch electrodes. METHODS AND RESULTS: Two hundred and one consecutive patients with persistent atrial fibrillation (147 male, mean age 63+/-1 years, duration of atrial fibrillation 6.3+/-1 months) were randomly assigned to cardioversion using either a sinusoidal monophasic or a truncated exponential biphasic shock wave form. The first half of patients were cardioverted using adhesive patch electrodes, the second half using hand-held steel paddle electrodes, and all patients using an anterior-posterior electrode position. Paddle electrodes successfully cardioverted 100/104 patients (96%) and patch electrodes 85/97 patients (88%, P=0.04). This effect was comparable to that of biphasic shocks: biphasic shocks cardioverted 102/104 patients (98%) and monophasic shocks 83/97 patients (86%, P=0.001). A beneficial effect of paddle electrodes was observed for both shock wave forms. After cross-over from an ineffective monophasic to a biphasic shock, cardioversion was successful in 198/201 (98.5%) patients. Unsuccessful cardioversion after cross-over (3/201 patients) only occurred with patch electrodes (P=0.07). CONCLUSION: Hand-held paddle electrodes increase success of external cardioversion of atrial fibrillation in this trial. This increase is of similar magnitude as the increase in cardioversion success achieved with biphasic shocks. A combination of biphasic shocks, paddle electrodes, and an anterior-posterior electrode position renders outcome of external cardioversion almost always successful (104/104 patients in this trial).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehi160

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 93

Metadata

Authors
Kirchhof, P., Mönnig, G., Wasmer, K., Heinecke, A., Breithardt, G., Eckardt, L., & Böcker, D.
Venue
European Heart Journal
Published
2005-02-25
Volume
26
Issue
13
Pages
1292-1297
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W1972150143
Cited by
93
References
3
FWCI
4.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A trial of self-adhesive patch electrodes and hand-held paddle electrodes for external cardioversion of atrial fibrillation (MOBIPAPA). https://app.cochat.ai/papers/10.1093/eurheartj/ehi160
The paper
Kirchhof, P., Mönnig, G., Wasmer, K., Heinecke, A., Breithardt, G., Eckardt, L., & Böcker, D. (2005). A trial of self-adhesive patch electrodes and hand-held paddle electrodes for external cardioversion of atrial fibrillation (MOBIPAPA). European Heart Journal. https://doi.org/10.1093/eurheartj/ehi160

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.