Detection of coronary artery stenoses using multi-detector CT with 16×0.75 collimation and 375 ms rotation

Achenbach, Stephan, Ropers, Dieter, Pohle, Falk-Karsten, Raaz, Dorette, von Erffa, Johannes, Yilmaz, Attila, Muschiol, Gerd, Daniel, Werner G. · 2005 · European Heart Journal

Abstract

AIMS: Insufficient spatial and temporal resolutions have limited image quality and accuracy of multi-detector CT (MDCT) for coronary artery visualization and detection of stenoses. We assessed the accuracy of a new 16-slice scanner with 370 ms rotation and 0.75 mm collimation for detection of coronary stenoses using an analysis approach based on coronary artery segments. METHODS AND RESULTS: Fifty consecutive patients scheduled for diagnostic coronary angiography in stable clinical condition and sinus rhythm were enrolled. All patients with a heart rate > 60 b.p.m. received 100 mg atenolol p.o. and up to four doses of 5 mg metoprolol i.v. before the scan. MDCT was performed using 16 x 0.75 mm collimation, 120 kV, and ECG-gated tube current modulation. Ninety millilitres of contrast agent was injected intravenously. MDCT images were visually analysed using the 16-segment coronary artery model of the American Heart Association and compared with invasive, quantitative coronary angiography in a blinded fashion. A significant stenosis was assumed if the diameter reduction was > or = 50%. Mean heart rate was 58 b.p.m. during MDCT. After exclusion of two patients with not fully evaluable data sets, MDCT correctly identified at least one coronary stenosis in all 25 patients with significant coronary lesions in angiography and correctly demonstrated the absence of stenoses in 19/23 patients (sensitivity 100%, specificity 83%). Sensitivity and specificity for all 50 patients were 93 and 83%, respectively. On a per-segment basis, nine coronary segments distal of total occlusions and 128 coronary segments with a reference diameter < 1.5 mm were excluded from the analysis. Twenty-eight of the included 663 segments (4%) were unevaluable due to calcification or motion artefact. In the remaining 635 segments, 50/53 stenoses were detected by MDCT (sensitivity 94%, specificity 96%, negative predictive value 99%, positive predictive value 69%). CONCLUSION: Increasing temporal and spatial resolutions of MDCT lead to improved evaluation and diagnostic accuracy for detection of coronary stenoses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehi326

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 172

Metadata

Authors
Achenbach, S., Ropers, D., Pohle, F.-K., Raaz, D., von Erffa, J., Yilmaz, A., Muschiol, G., & Daniel, W. G.
Venue
European Heart Journal
Published
2005-05-27
Volume
26
Issue
19
Pages
1978-1986
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2137380265
Cited by
172
References
1
FWCI
25.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detection of coronary artery stenoses using multi-detector CT with 16×0.75 collimation and 375 ms rotation. https://app.cochat.ai/papers/10.1093/eurheartj/ehi326
The paper
Achenbach, S., Ropers, D., Pohle, F.-K., Raaz, D., von Erffa, J., Yilmaz, A., Muschiol, G., & Daniel, W. G. (2005). Detection of coronary artery stenoses using multi-detector CT with 16×0.75 collimation and 375 ms rotation. European Heart Journal. https://doi.org/10.1093/eurheartj/ehi326

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.