Detection of coronary artery stenoses using multi-detector CT with 16×0.75 collimation and 375 ms rotation
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
AIMS: Insufficient spatial and temporal resolutions have limited image quality and accuracy of multi-detector CT (MDCT) for coronary artery visualization and detection of stenoses. We assessed the accuracy of a new 16-slice scanner with 370 ms rotation and 0.75 mm collimation for detection of coronary stenoses using an analysis approach based on coronary artery segments. METHODS AND RESULTS: Fifty consecutive patients scheduled for diagnostic coronary angiography in stable clinical condition and sinus rhythm were enrolled. All patients with a heart rate > 60 b.p.m. received 100 mg atenolol p.o. and up to four doses of 5 mg metoprolol i.v. before the scan. MDCT was performed using 16 x 0.75 mm collimation, 120 kV, and ECG-gated tube current modulation. Ninety millilitres of contrast agent was injected intravenously. MDCT images were visually analysed using the 16-segment coronary artery model of the American Heart Association and compared with invasive, quantitative coronary angiography in a blinded fashion. A significant stenosis was assumed if the diameter reduction was > or = 50%. Mean heart rate was 58 b.p.m. during MDCT. After exclusion of two patients with not fully evaluable data sets, MDCT correctly identified at least one coronary stenosis in all 25 patients with significant coronary lesions in angiography and correctly demonstrated the absence of stenoses in 19/23 patients (sensitivity 100%, specificity 83%). Sensitivity and specificity for all 50 patients were 93 and 83%, respectively. On a per-segment basis, nine coronary segments distal of total occlusions and 128 coronary segments with a reference diameter < 1.5 mm were excluded from the analysis. Twenty-eight of the included 663 segments (4%) were unevaluable due to calcification or motion artefact. In the remaining 635 segments, 50/53 stenoses were detected by MDCT (sensitivity 94%, specificity 96%, negative predictive value 99%, positive predictive value 69%). CONCLUSION: Increasing temporal and spatial resolutions of MDCT lead to improved evaluation and diagnostic accuracy for detection of coronary stenoses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gibbons, R. J., Abrams, J., Chatterjee, K., Daley, J., Deedwania, P. C., Douglas, J. S., Ferguson, T. B., Fihn, S. D., Fraker, T. D., Gardin, J. M., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02848-6 · Cited by 1,689
Nieman, K., Cademartiri, F., Lemos, P. A., Raaijmakers, R., Pattynama, P. M. T., & de Feyter, P. J. (2002) · Circulation · doi:10.1161/01.cir.0000037222.58317.3d · Cited by 956
Ropers, D., Baum, U., Pohle, K., Anders, K., Ulzheimer, S., Ohnesorge, B., Schlundt, C., Bautz, W., Daniel, W. G., & Achenbach, S. (2003) · Circulation · doi:10.1161/01.cir.0000055738.31551.a9 · Cited by 930
Self-citationCoronary angiography with multi-slice computed tomography
Nieman, K., Oudkerk, M., Rensing, B. J., van Ooijen, P., Munne, A., van Geuns, R.-J., & de Feyter, P. J. (2001) · The Lancet · doi:10.1016/s0140-6736(00)04058-7 · Cited by 725
Achenbach, S., Giesler, T., Ropers, D., Ulzheimer, S., Derlien, H., Schulte, C., Wenkel, E., Moshage, W., Bautz, W., Daniel, W. G., et al. (2001) · Circulation · doi:10.1161/01.cir.103.21.2535 · Cited by 667
Self-citationJakobs, T. F., Becker, C. R., Ohnesorge, B., Flohr, T., Suess, C., Schoepf, U. J., & Reiser, M. F. (2002) · European Radiology · doi:10.1007/s00330-001-1278-x · Cited by 615
Ohnesorge, B., Flohr, T., Becker, C., Kopp, A. F., Schoepf, U. J., Baum, U., Knez, A., Klingenbeck-Regn, K., & Reiser, M. F. (2000) · Radiology · doi:10.1148/radiology.217.2.r00nv30564 · Cited by 516
Radiation Dose in Computed Tomography of the Heart
Morin, R. L., Gerber, T. C., & McCollough, C. H. (2003) · Circulation · doi:10.1161/01.cir.0000048965.56529.c2 · Cited by 457
Noninvasive Coronary Angiography by Retrospectively ECG-Gated Multislice Spiral CT
Achenbach, S., Ulzheimer, S., Baum, U., Kachelrieß, M., Ropers, D., Giesler, T., Bautz, W., Daniel, W. G., Kalender, W. A., & Moshage, W. (2000) · Circulation · doi:10.1161/01.cir.102.23.2823 · Cited by 434
Self-citationHoffmann, U., Moselewski, F., Cury, R. C., Ferencik, M., Jang, I.-K., Diaz, L. J., Abbara, S., Brady, T. J., & Achenbach, S. (2004) · Circulation · doi:10.1161/01.cir.0000145614.07427.9f · Cited by 413
Self-citationMultislice spiral computed tomography coronary angiography in patients with stable angina pectoris
Mollet, N. R., Cademartiri, F., Nieman, K., Saia, F., Lemos, P. A., McFadden, E. P., Pattynama, P. M. T., Serruys, P. W., Krestin, G. P., & de Feyter, P. J. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.03.032 · Cited by 406 · cited 1×
“Previous studies, however, have shown that interobserver variability is low.(13,14) Inaccuracies may have occured due to the assignment of coronary segments to the MDCT data sets and invasive coronary angiograms, it has so far not been evaluated how accurately coronary artery segments, which are usually identified thr…”
BackgroundRadiation Exposure during Cardiac CT: Effective Doses at Multi–Detector Row CT and Electron-Beam CT
Hunold, P., Vogt, F. M., Schmermund, A., Debatin, J. F., Kerkhoff, G., Budde, T., Erbel, R., Ewen, K., & Barkhausen, J. (2003) · Radiology · doi:10.1148/radiol.2261011365 · Cited by 405
Gibbons, R. J., Chatterjee, K., Daley, J., Douglas, J. S., Fihn, S. D., Gardin, J. M., Grunwald, M. A., Levy, D., Lytle, B. W., O’Rourke, R. A., et al. (1999) · Circulation · doi:10.1161/01.cir.99.21.2829 · Cited by 367
Kuettner, A., Trabold, T., Schroeder, S., Feyer, A., Beck, T., Brueckner, A., Heuschmid, M., Burgstahler, C., Kopp, A. F., & Claussen, C. D. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.05.079 · Cited by 280 · cited 9×
“Our study is different from previous studies performed by MDCT. Scanner technology has been improved over the material used in previous studies (with faster tube rotation, resulting in a higher temporal resolution of 188 ms in the centre of the field of view and with a stronger X-ray tube, resulting in less image nois…”
BackgroundInfluentialAccuracy of thin-slice computed tomography in the detection of coronary stenoses
MARTUSCELLI, E. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.03.024 · Cited by 259 · cited 2×
“Previous studies, however, have shown that interobserver variability is low.(13,14) Inaccuracies may have occured due to the assignment of coronary segments to the MDCT data sets and invasive coronary angiograms, it has so far not been evaluated how accurately coronary artery segments, which are usually identified thr…”
BackgroundResultKopp, A. (2002) · European Heart Journal · doi:10.1016/s0195-668x(02)93264-1 · Cited by 252
Mahnken, A. H., Koos, R., Katoh, M., Spuentrup, E., Busch, P., Wildberger, J. E., K�hl, H. P., & Günther, R. W. (2005) · European Radiology · doi:10.1007/s00330-004-2592-x · Cited by 132
Herzog, C., Abolmaali, N., Balzer, J. O., Baunach, S., Ackermann, H., Doğan, S., Britten, M. B., & Vogl, T. J. (2002) · European Radiology · doi:10.1007/s00330-002-1553-5 · Cited by 130
Schuijf, J. D., Bax, J. J., Salm, L. P., Jukema, J. W., Lamb, H. J., van der Wall, E. E., & Roos, A. (2005) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2004.11.002 · Cited by 127
Halliburton, S. S., Petersilka, M., Schvartzman, P. R., Obuchowski, N. A., & White, R. D. (2003) · International journal of cardiac imaging · doi:10.1023/a:1021793420007 · Cited by 93
Noninvasive coronary angiography—an acceptable alternative?
Achenbach, S., & Daniel, W. G. (2001) · New England Journal of Medicine · doi:10.1056/nejm200112273452609 · Cited by 92
Self-citation
Cited by
Budoff, M. J., Achenbach, S., Blumenthal, R. S., Carr, J. J., Goldin, J. G., Greenland, P., Guerci, A. D., Lima, J. A. C., Rader, D. J., Rubin, G. D., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178458 · Cited by 1,398
Self-citationBluemke, D. A., Achenbach, S., Budoff, M., Gerber, T. C., Gersh, B., Hillis, L. D., Hundley, W. G., Manning, W. J., Printz, B. F., Stuber, M., et al. (2008) · Circulation · doi:10.1161/circulationaha.108.189695 · Cited by 461
Self-citationVanhoenacker, P. K., Heijenbrok-Kal, M. H., Van Heste, R., Decramer, I., Van Hoe, L. R., Wijns, W., & Hunink, M. G. M. (2007) · Radiology · doi:10.1148/radiol.2442061218 · Cited by 442
Accuracy of 16-Row Multidetector Computed Tomography for the Assessment of Coronary Artery Stenosis
Garcia, M. J., Lessick, J., Hoffmann, M. H. K., & CATSCAN Study Investigators, F. T. (2006) · JAMA · doi:10.1001/jama.296.4.403 · Cited by 301
Pohle, K., Achenbach, S., MacNeill, B., Ropers, D., Ferencik, M., Moselewski, F., Hoffmann, U., Brady, T. J., Jang, I.-K., & Daniel, W. G. (2007) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2006.01.013 · Cited by 289
Self-citation
Metadata
- Authors
- Achenbach, S., Ropers, D., Pohle, F.-K., Raaz, D., von Erffa, J., Yilmaz, A., Muschiol, G., & Daniel, W. G.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-05-27
- Volume
- 26
- Issue
- 19
- Pages
- 1978-1986
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2137380265
- Cited by
- 172
- References
- 21
- FWCI
- 25.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.