CoChat

Outcome of pregnancy in patients after repair of aortic coarctation

Open access
Vriend, Joris W.J., Drenthen, Wim, Pieper, Petronella G., Roos-Hesselink, Jolien W., Zwinderman, Aeiko H., van Veldhuisen, Dirk J., Mulder, Barbara J.M. · 2005 · European Heart Journal
Cited by 147

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

AIMS: Nowadays, most women born with aortic coarctation reach childbearing age. However, data on outcome of pregnancy in women after repair of aortic coarctation are scarce. The aim of this study was to report on maternal and neonatal outcome of pregnancy in women after aortic coarctation repair. METHODS AND RESULTS: The CONCOR national registry on congenital heart disease in The Netherlands was reviewed for women of childbearing age (> or =18 years old) with a history of aortic coarctation repair. Medical history and maternal, obstetrical, and neonatal outcome were determined. Fifty-four of the 100 women included had a history of pregnancy. The 54 women had 126 pregnancies resulting in 98 successful pregnancies, 22 miscarriages, and six abortions. The success rate was estimated as 0.778 (SE 0.002) including abortions and 0.817 (SE 0.002) excluding abortions. There were 85 vaginal deliveries, seven vaginal deliveries with epidural analgesia, and six caesarean sections. There were two neonatal deaths. A total of 26 pregnancies were complicated by a hypertensive disorder of pregnancy. There were 21 pregnancies in 14 women complicated by hypertension and five pregnancies in four women complicated by pre-eclampsia. The hypertension- and pre-eclampsia-probabilities were estimated as 0.183 (SE 0.285) and 0.061 (SE 0.211), respectively. During pregnancy, five patients had an increase > or =15 mmHg across the site of repair at echocardiography, but only one patient required reintervention for recoarctation after delivery. Four of the 98 children (4%) had a congenital heart defect. CONCLUSION: Pregnancy is well tolerated in women after repair of aortic coarctation. However, an excess of miscarriages and hypertensive disorders of pregnancy were found.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehi338

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 147

Metadata

Authors
Vriend, J. W. J., Drenthen, W., Pieper, P. G., Roos-Hesselink, J. W., Zwinderman, A. H., van Veldhuisen, D. J., & Mulder, B. J. M.
Venue
European Heart Journal
Published
2005-06-09
Volume
26
Issue
20
Pages
2173-2178
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2147269294
Cited by
147
References
2
FWCI
3.18
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Outcome of pregnancy in patients after repair of aortic coarctation. https://app.cochat.ai/papers/10.1093/eurheartj/ehi338
The paper
Vriend, J. W. J., Drenthen, W., Pieper, P. G., Roos-Hesselink, J. W., Zwinderman, A. H., van Veldhuisen, D. J., & Mulder, B. J. M. (2005). Outcome of pregnancy in patients after repair of aortic coarctation. European Heart Journal. https://doi.org/10.1093/eurheartj/ehi338

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.