The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Electrical storm in patients with an implantable defibrillator: incidence, features, and preventive therapy: insights from a randomized trial
Open accessAbstract
AIMS: The purpose of this study was to assess the incidence, features, and clinical sequelae of 'electrical storm' (ES). METHODS AND RESULTS: This study is a prospectively designed secondary analysis of SHIELD; a randomized trial of azimilide for suppression of ventricular tachycardia/fibrillation (VT/VF) leading to implanted cardioverter defibrillator (ICD) therapies. Systematic and rigorous follow-up and blinded adjudication of ICD therapy allowed identification of all ESs (>/=3 separate VT/VF episodes leading to ICD therapies within 24 h). Of 633 ICD recipients, 148 (23%) experienced at least one ES over 1-year follow-up. No clinical predictors of ES were identified. Frequent VT episodes accounted for 91% of all ESs, with the remaining being VF alone or both VT plus VF. ES led to a 3.1-fold increase in arrhythmia-related hospitalization (95% CI 2.3-4.3; P<0.0001) compared with patients with isolated VT/VF, and to a 10.2-fold increase (95% CI 6.4-16.3; P<0.0001) compared with patients without VT/VF. Compared with placebo, azimilide (75 and 125 mg/day) reduced the risk of recurrent ES by 37% (HR=0.63, 95% CI 0.35-1.11, P=0.11) and 55% (HR=0.45, 95% CI 0.23-0.87, P=0.018), respectively. However, the reduction in time-to-first ES did not reach statistical significance by both doses (75 and 125 mg) of azimilide (HR=0.82, 95% CI 0.56-1.19, P=0.29 and HR=0.69, 95% CI 0.46-1.04, P=0.07), respectively. CONCLUSION: ES is common and unpredictable in ICD recipients and it is a strong predictor of hospitalization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cox’s regression model for counting processes: A large sample study
Andersen, P. K., & Gill, R. D. (1982) · The Annals of Statistics · doi:10.1214/aos/1176345976 · Cited by 4,419
Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165
Semiparametric regression for the mean and rate functions of recurrent events
Lin, D. Y., Wei, L. J., Yang, I., & Ying, Z. (2000) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/1467-9868.00259 · Cited by 969
Dorian, P., Borggrefe, M., Al-Khalidi, H. R., Hohnloser, S. H., Brum, J. M., Tatla, D. S., Brachmann, J., Myerburg, R. J., Cannom, D. S., van der Laan, M., et al. (2004) · Circulation · doi:10.1161/01.cir.0000149240.98971.a8 · Cited by 155
Self-citation
Cited by
2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2019) · EP Europace · doi:10.1093/europace/euz132 · Cited by 475
Carbucicchio, C., Santamaria, M., Trevisi, N., Maccabelli, G., Giraldi, F., Fassini, G., Riva, S., Moltrasio, M., Cireddu, M., Veglia, F., et al. (2008) · Circulation · doi:10.1161/circulationaha.106.686534 · Cited by 460
2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2019.03.002 · Cited by 431
Di Biase, L., Santangeli, P., Burkhardt, D. J., Bai, R., Mohanty, P., Carbucicchio, C., Dello Russo, A., Casella, M., Mohanty, S., Pump, A., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.03.044 · Cited by 422
EHRA/HRS/APHRS expert consensus on ventricular arrhythmias
Pedersen, C. T., Kay, G. N., Kalman, J., Borggrefe, M., Della-Bella, P., Dickfeld, T., Dorian, P., Huikuri, H., Kim, Y.-H., Knight, B., et al. (2014) · Europace · doi:10.1093/europace/euu194 · Cited by 327
Self-citation
Metadata
- Authors
- Hohnloser, S. H., Al-Khalidi, H. R., Pratt, C. M., Brum, J. M., Tatla, D. S., Tchou, P., Dorian, P., & on behalf of the SHock Inhibition Evaluation with AzimiLiDe (SHIELD) Investigators
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-04-07
- Volume
- 27
- Issue
- 24
- Pages
- 3027-3032
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2115951287
- Cited by
- 193
- References
- 4
- FWCI
- 5.03
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrical storm in patients with an implantable defibrillator: incidence, features, and preventive therapy: insights from a randomized trial. https://app.cochat.ai/papers/10.1093/eurheartj/ehl276
- The paper
- Hohnloser, S. H., Al-Khalidi, H. R., Pratt, C. M., Brum, J. M., Tatla, D. S., Tchou, P., Dorian, P., & on behalf of the SHock Inhibition Evaluation with AzimiLiDe (SHIELD) Investigators. (2006). Electrical storm in patients with an implantable defibrillator: incidence, features, and preventive therapy: insights from a randomized trial. European Heart Journal. https://doi.org/10.1093/eurheartj/ehl276
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.