The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
The long-term cost-effectiveness of cardiac resynchronization therapy with or without an implantable cardioverter-defibrillator
Abstract
AIMS: Cardiac resynchronization therapy (CRT-P) is an effective treatment for patients with heart failure and cardiac dyssynchrony with moderate or severe symptoms despite pharmacological therapy. The addition of an implantable cardioverter-defibrillator (ICD) function may further reduce the risk of sudden death. We assessed the cost-effectiveness of CRT-P compared with medical therapy (MT) alone, and the cost-effectiveness of CRT-ICD + MT compared with CRT-P + MT, on incremental cost per quality adjusted life year (QALY) and life year using data from two landmark clinical trials. METHODS AND RESULTS: A Markov model with Monte Carlo simulation to assess costs, life years, and QALYs associated with CRT (+/- ICD) and MT in patients with heart failure and cardiac dyssynchrony, on the basis of a UK healthcare perspective was constructed. NYHA class distribution and transitions, associated health utilities, rates and cause of hospitalization and death were estimated from individual patient data from the CArdiac REsychronization in Heart Failure (CARE-HF trial). The estimated additional benefit on survival of an ICD was based on results from COMPANION. The base case analysis used 10 000 individual life-time simulations assuming a battery life of 6 years for CRT-P and 7 years for CRT-ICD. From a life-time perspective in a 65-year-old patient, the incremental cost-effectiveness of CRT-P compared with MT is 7538 euros (95% CI 5325-11,784 euros) per QALY gained and 7011euros (95% CI 5346-10,003 euros) per life year gained. The incremental cost-effectiveness of CRT-ICD compared with CRT-P is 47,909 euros (95% CI 35,703-79,438 euros) per QALY gained, and 35,864 euros (95% CI 26,709-56,353 euros) per life year gained. CONCLUSION: Long-term treatment with CRT-P appears cost-effective compared with MT alone. From a life-time perspective, assuming a reasonable life expectancy when receiving effective treatment for heart failure, CRT-ICD may also be considered cost-effective when compared with CRT-P + MT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bristow, M. R., Saxon, L. A., Boehmer, J., Krueger, S., Kass, D. A., De Marco, T., Carson, P., DiCarlo, L., DeMets, D., White, B. G., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032423 · Cited by 5,812
Cardiac Resynchronization in Chronic Heart Failure
Abraham, W. T., Fisher, W. G., Smith, A. L., Delurgio, D. B., Leon, A. R., Loh, E., Kocovic, D. Z., Packer, M., Clavell, A. L., Hayes, D. L., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013168 · Cited by 4,648
Cited by
Authors/Task Force Members, Vardas, P. E., Auricchio, A., Blanc, J.-J., Daubert, J.-C., Drexler, H., Ector, H., Gasparini, M., Linde, C., Morgado, F. B., et al. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm305 · Cited by 902
Self-citationMcAlister, F. A., Ezekowitz, J., Hooton, N., Vandermeer, B., Spooner, C., Dryden, D. M., Page, R. L., Hlatky, M. A., & Rowe, B. H. (2007) · JAMA · doi:10.1001/jama.297.22.2502 · Cited by 569
Daubert, J.-C., Saxon, L., Adamson, P. B., Auricchio, A., Berger, R. D., Beshai, J. F., Breithard, O., Brignole, M., Cleland, J., DeLurgio, D. B., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2012.07.025 · Cited by 467
Self-citationMetra, M., Ponikowski, P., Dickstein, K., McMurray, J. J. V., Gavazzi, A., Bergh, C.-H., Fraser, A. G., Jaarsma, T., Pitsis, A., Mohacsi, P., et al. (2007) · European Journal of Heart Failure · doi:10.1016/j.ejheart.2007.04.003 · Cited by 395
Avoiding non-responders to cardiac resynchronization therapy: a practical guide
Daubert, C., Behar, N., Martins, R. P., Mabo, P., & Leclercq, C. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw270 · Cited by 311
Metadata
- Authors
- Yao, G., Freemantle, N., Calvert, M. J., Bryan, S., Daubert, J.-C., & Cleland, J. G. F.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-06-13
- Volume
- 28
- Issue
- 1
- Pages
- 42-51
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2032220099
- Cited by
- 190
- References
- 2
- FWCI
- 9.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The long-term cost-effectiveness of cardiac resynchronization therapy with or without an implantable cardioverter-defibrillator. https://app.cochat.ai/papers/10.1093/eurheartj/ehl382
- The paper
- Yao, G., Freemantle, N., Calvert, M. J., Bryan, S., Daubert, J.-C., & Cleland, J. G. F. (2006). The long-term cost-effectiveness of cardiac resynchronization therapy with or without an implantable cardioverter-defibrillator. European Heart Journal. https://doi.org/10.1093/eurheartj/ehl382
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.