The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Role of the implantable defibrillator among elderly patients with a history of life-threatening ventricular arrhythmias
Abstract
AIMS: The implantable defibrillator (ICD) reduces arrhythmic and all-cause mortality in patients with a history of life-threatening ventricular arrhythmias. However, its effectiveness in elderly patients is uncertain, given their competing risk of non-arrhythmic death. METHODS AND RESULTS: Individual patient data from all three secondary prevention trials comparing the ICD to amiodarone were pooled. Patients were divided into two groups based on age < 75 and > or = 75 years. Patient characteristics were reported and the effect of the ICD on all-cause mortality and arrhythmic death was determined for each group. The effect of age on these outcomes was determined by evaluating the interaction term (age-treatment). A total of 1866 patients were included in this analysis. Their mean age was 63.7 +/- 10.4 years (intra-quartile range 58-71 years). There were 252 patients > or = 75 years old (13.5% of total). Patients > or = 75 years old had a similar left ventricular (LV) ejection fraction (EF)(32.6 +/- 13.7 vs. 33.8 +/- 14.9%, P = 0.20) and baseline prevalence of NYHA class 3 or 4 heart (12.3 vs. 11.8%, P = 0.38) failure as younger patients, but were less likely to have ventricular fibrillation as their presenting arrhythmia (39 vs. 53%, P = 0.0001). Over a mean follow-up of 2.3 years, older patients were more likely to die of non-arrhythmic death (8.74% per year vs. 3.96% per year, P = 0.001) and arrhythmic death (6.73% per year vs. 3.84% per year, P = 0.03). The ICD significantly reduced all-cause and arrhythmic death in patients < 75 years old (all-cause death HR = 0.69, 95% CI: 0.56-0.85, P < 0.0001; arrhythmic death HR = 0.44, 95% CI: 0.32-0.62, P < 0.0001), but not in patients > or = 75 years old (all-cause death HR = 1.06, 95% CI: 0.69-1.64, P = 0.79; arrhythmic death HR = 0.90, 95% CI: 0.42-1.95, P = 0.79). The interaction between age > or = 75 and ICD use was of borderline significance in each case (P = 0.09 and P = 0.11, respectively). CONCLUSION: Elderly patients with a history of life-threatening ventricular arrhythmias have a high incidence of non-arrhythmic death. In these patients, the ICD may not afford the same survival advantage over amiodarone that is seen in younger patients. ICD therapy should not be withheld based on age alone; however, physicians should carefully consider the risk of non-arrhythmic death among elderly patients when selecting the appropriate therapy for an individual.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
Bristow, M. R., Saxon, L. A., Boehmer, J., Krueger, S., Kass, D. A., De Marco, T., Carson, P., DiCarlo, L., DeMets, D., White, B. G., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032423 · Cited by 5,812
Cited by
2013 ACCF/AHA Guideline for the Management of Heart Failure
Yancy, C. W., Jessup, M., Bozkurt, B., Butler, J., Casey, D. E., Drazner, M. H., Fonarow, G. C., Geraci, S. A., Horwich, T., Januzzi, J. L., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.05.019 · Cited by 12,536
Priori, S. G., Blomström-Lundqvist, C., Mazzanti, A., Blom, N., Borggrefe, M., Camm, J., Elliott, P. M., Fitzsimons, D., Hatala, R., Hindricks, G., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv316 · Cited by 3,893
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
Yancy, C. W., Jessup, M., Bozkurt, B., Butler, J., Casey, D. E., Drazner, M. H., Fonarow, G. C., Geraci, S. A., Horwich, T., Januzzi, J. L., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31829e8776 · Cited by 2,106
Writing Committee Members, Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., et al. (2008) · Circulation · doi:10.1161/circualtionaha.108.189742 · Cited by 1,774
Metadata
- Authors
- Healey, J. S., Hallstrom, A. P., Kuck, K.-H., Nair, G., Schron, E. P., Roberts, R. S., Morillo, C. A., & Connolly, S. J.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-02-05
- Volume
- 28
- Issue
- 14
- Pages
- 1746-1749
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2162079707
- Cited by
- 170
- References
- 2
- FWCI
- 7.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Role of the implantable defibrillator among elderly patients with a history of life-threatening ventricular arrhythmias. https://app.cochat.ai/papers/10.1093/eurheartj/ehl438
- The paper
- Healey, J. S., Hallstrom, A. P., Kuck, K.-H., Nair, G., Schron, E. P., Roberts, R. S., Morillo, C. A., & Connolly, S. J. (2007). Role of the implantable defibrillator among elderly patients with a history of life-threatening ventricular arrhythmias. European Heart Journal. https://doi.org/10.1093/eurheartj/ehl438
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.