Role of the implantable defibrillator among elderly patients with a history of life-threatening ventricular arrhythmias
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
AIMS: The implantable defibrillator (ICD) reduces arrhythmic and all-cause mortality in patients with a history of life-threatening ventricular arrhythmias. However, its effectiveness in elderly patients is uncertain, given their competing risk of non-arrhythmic death. METHODS AND RESULTS: Individual patient data from all three secondary prevention trials comparing the ICD to amiodarone were pooled. Patients were divided into two groups based on age < 75 and > or = 75 years. Patient characteristics were reported and the effect of the ICD on all-cause mortality and arrhythmic death was determined for each group. The effect of age on these outcomes was determined by evaluating the interaction term (age-treatment). A total of 1866 patients were included in this analysis. Their mean age was 63.7 +/- 10.4 years (intra-quartile range 58-71 years). There were 252 patients > or = 75 years old (13.5% of total). Patients > or = 75 years old had a similar left ventricular (LV) ejection fraction (EF)(32.6 +/- 13.7 vs. 33.8 +/- 14.9%, P = 0.20) and baseline prevalence of NYHA class 3 or 4 heart (12.3 vs. 11.8%, P = 0.38) failure as younger patients, but were less likely to have ventricular fibrillation as their presenting arrhythmia (39 vs. 53%, P = 0.0001). Over a mean follow-up of 2.3 years, older patients were more likely to die of non-arrhythmic death (8.74% per year vs. 3.96% per year, P = 0.001) and arrhythmic death (6.73% per year vs. 3.84% per year, P = 0.03). The ICD significantly reduced all-cause and arrhythmic death in patients < 75 years old (all-cause death HR = 0.69, 95% CI: 0.56-0.85, P < 0.0001; arrhythmic death HR = 0.44, 95% CI: 0.32-0.62, P < 0.0001), but not in patients > or = 75 years old (all-cause death HR = 1.06, 95% CI: 0.69-1.64, P = 0.79; arrhythmic death HR = 0.90, 95% CI: 0.42-1.95, P = 0.79). The interaction between age > or = 75 and ICD use was of borderline significance in each case (P = 0.09 and P = 0.11, respectively). CONCLUSION: Elderly patients with a history of life-threatening ventricular arrhythmias have a high incidence of non-arrhythmic death. In these patients, the ICD may not afford the same survival advantage over amiodarone that is seen in younger patients. ICD therapy should not be withheld based on age alone; however, physicians should carefully consider the risk of non-arrhythmic death among elderly patients when selecting the appropriate therapy for an individual.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
The Effect of Cardiac Resynchronization on Morbidity and Mortality in Heart Failure
Cleland, J. G. F., Daubert, J.-C., Erdmann, E., Freemantle, N., Gras, D., Kappenberger, L., & Tavazzi, L. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa050496 · Cited by 6,276
Bristow, M. R., Saxon, L. A., Boehmer, J., Krueger, S., Kass, D. A., De Marco, T., Carson, P., DiCarlo, L., DeMets, D., White, B. G., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032423 · Cited by 5,812
(1997) · New England Journal of Medicine · doi:10.1056/nejm199711273372202 · Cited by 3,232
Connolly, S. J., Gent, M., Roberts, R. S., Dorian, P., Roy, D., Sheldon, R. S., Mitchell, L. B., Green, M. S., Klein, G. J., & O’Brien, B. (2000) · Circulation · doi:10.1161/01.cir.101.11.1297 · Cited by 1,607
Self-citationKuck, K.-H., Cappato, R., Siebels, J., & Rüppel, R. (2000) · Circulation · doi:10.1161/01.cir.102.7.748 · Cited by 1,482
Self-citationMeta-analysis of the implantable cardioverter defibrillator secondary prevention trials
Connolly, S. (2000) · European Heart Journal · doi:10.1053/euhj.2000.2476 · Cited by 1,126 · cited 4×
“35%.(4) Given the cost(5) and potential complications(1) of these devices, it is desirable to identify patients who are most likely to benefit.”
BackgroundMethodInfluentialSelf-citationPreferences for quality of life or survival expressed by patients with heart failure
Lewis, E. F., Johnson, P. A., Johnson, W., Collins, C., Griffin, L., & Stevenson, L. W. (2001) · The Journal of Heart and Lung Transplantation · doi:10.1016/s1053-2498(01)00298-4 · Cited by 433 · cited 2×
“For patients with co-morbidities, such as advanced heart failure, life-prolonging therapywith an ICD,may be less attractive than other therapies, such as cardiac resynchronization,(16) that may also improve quality of life.(14) Overall, in the present analysis, almost 20% of elderly patients died within 1 year of thei…”
BackgroundIncidence and predictors of cardiac perforation after permanent pacemaker placement
Mahapatra, S., Bybee, K. A., Bunch, T. J., Espinosa, R. E., Sinak, L. J., McGoon, M. D., & Hayes, D. L. (2005) · Heart Rhythm · doi:10.1016/j.hrthm.2005.06.011 · Cited by 300
Krahn, A. D., Connolly, S. J., Roberts, R. S., & Gent, M. (2004) · American Heart Journal · doi:10.1016/j.ahj.2003.12.017 · Cited by 121 · cited 1×
“The increase in nonarrhythmic death in the elderly is due to an increase in both non-cardiac and heart failure mortality, and is consistent with prior observational reports indicating a lower proportional risk of arrhythmic death among the elderly.(6) In fact, the rate of non-cardiac mortality in this pooled analysis…”
ResultSelf-citationCost-Effectiveness of the Implantable Cardioverter-Defibrillator
OʼBrien, B. J., Connolly, S. J., Goeree, R. A., Blackhouse, G., Willan, A. R., Yee, R. K., Roberts, R. S., & Gent, M. (2001) · Circulation · doi:10.1161/01.cir.103.10.1416 · Cited by 121
Self-citationEfficacy of the Implantable Cardioverter-Defibrillator in the Elderly
PANOTOPOULOS, P. T. H., Axtell, K., Anderson, A. J., Sra, J. S., Blanck, Z., Deshpande, S., Biehl, M. L., Keelan, E. T., Jazayeri, M. R., Akhtar, M., et al. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(96)00527-x · Cited by 74 · cited 3×
“The excess of non-arrhythmic deaths among elderly patients in this study is clear, consistent with previous reports,(6,7) and provides biological plausibility for a reduced effectiveness of ICDs in the elderly.(7) The results of this analysis do not apply to the use of the ICD as primary prophylaxis against arrhythmic…”
BackgroundResultInfluentialComplications of Pacemakers and Defibrillators in the Elderly
BAILEY, S. M., & Wilkoff, B. L. (2006) · The American Journal of Geriatric Cardiology · doi:10.1111/j.1076-7460.2006.04815.x · Cited by 53
Feasibility of Implantable Cardioverter Defibrillator Use in Elderly Patients:
Noseworthy, P. A., Lashevsky, I., Dorian, P., Greene, M., Cvitkovic, S., & Newman, D. M. (2004) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2004.00445.x · Cited by 46
Duray, G. Z., Richter, S., Manegold, J. C., Israel, C. W., Grönefeld, G., & Hohnloser, S. H. (2005) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-006-5200-y · Cited by 43 · cited 2×
“40%).(10) The more favourable outcomes among elderly patients in this later report may, as the authors suggest,(10) reflect advances in the medical therapy of heart failure or may simply result from the lower age cut-off used to define the elderly.”
Result
Cited by
2013 ACCF/AHA Guideline for the Management of Heart Failure
Yancy, C. W., Jessup, M., Bozkurt, B., Butler, J., Casey, D. E., Drazner, M. H., Fonarow, G. C., Geraci, S. A., Horwich, T., Januzzi, J. L., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.05.019 · Cited by 12,536
Priori, S. G., Blomström-Lundqvist, C., Mazzanti, A., Blom, N., Borggrefe, M., Camm, J., Elliott, P. M., Fitzsimons, D., Hatala, R., Hindricks, G., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv316 · Cited by 3,893
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
Yancy, C. W., Jessup, M., Bozkurt, B., Butler, J., Casey, D. E., Drazner, M. H., Fonarow, G. C., Geraci, S. A., Horwich, T., Januzzi, J. L., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31829e8776 · Cited by 2,106
Writing Committee Members, Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., et al. (2008) · Circulation · doi:10.1161/circualtionaha.108.189742 · Cited by 1,774
Metadata
- Authors
- Healey, J. S., Hallstrom, A. P., Kuck, K.-H., Nair, G., Schron, E. P., Roberts, R. S., Morillo, C. A., & Connolly, S. J.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-02-05
- Volume
- 28
- Issue
- 14
- Pages
- 1746-1749
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2162079707
- Cited by
- 170
- References
- 15
- FWCI
- 7.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.