Non-invasive coronary computed tomographic angiography for patients with suspected coronary artery disease: the Coronary Angiography by Computed Tomography with the Use of a Submillimeter resolution (CACTUS) trial
The DOI matches its Crossref record.
Abstract
BACKGROUND: Non-invasive coronary angiography by multislice spiral computed tomography (MSCT) is a promising method for the diagnosis of coronary artery disease (CAD). However, the clinical role of this method has not been established for specific patient cohorts. Therefore, the objective of the current prospective, blinded study was to investigate the diagnostic value of coronary MSCT angiography in patients with an intermediate pre-test probability for having CAD when compared with invasive angiography. METHODS AND RESULTS: A total of 243 patients with an intermediate pre-test probability for having CAD were asked to undergo coronary 16- or 64-slice CT angiography before planned invasive angiography from 12 September 2003 to 13 July 2005. The primary end point was defined as the diagnostic accuracy in the detection of significant coronary stenosis (> or =50% lumen diameter reduction) on a per-patient and an 'intention-to-diagnose'-based analysis. Secondary end points comprised per-artery and per segment-based analyses as well as the comparison of diagnostic accuracy of 16- vs. 64-slice MSCT angiography. Of 243 enrolled patients, 129 and 114 patients were studied by 16- and 64-slice CT angiography, respectively. The overall sensitivity, negative predictive value, and specificity for CAD detection by MSCT were 99% (95% CI, 94-99%), 99% (95% CI, 94-99%), and 75% (95% CI, 67-82%), respectively. On a per-segment basis, the use of 64-slice CT was associated with significantly less inconclusive segments (7.4 vs. 11.3%, P < 0.01), resulting in a trend to an improved specificity (92 vs. 88%, P = 0.09). CONCLUSION: In patients with an intermediate pre-test probability for having CAD this large, prospective trial demonstrates that non-invasive coronary CT angiography is a very sensitive method for CAD detection. Furthermore, this method allows ruling out CAD very reliably and safely. Finally, 64-slice CT appears to be superior for CAD detection when compared with 16-slice CT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bluemke, D. A., Achenbach, S., Budoff, M., Gerber, T. C., Gersh, B., Hillis, L. D., Hundley, W. G., Manning, W. J., Printz, B. F., Stuber, M., et al. (2008) · Circulation · doi:10.1161/circulationaha.108.189695 · Cited by 461
Coronary Computed Tomography Angiography From Clinical Uses to Emerging Technologies
Abdelrahman, K. M., Chen, M. Y., Dey, A. K., Virmani, R., Finn, A. V., Khamis, R. Y., Choi, A. D., Min, J. K., Williams, M. C., Buckler, A. J., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.06.076 · Cited by 297
Hirai, N., Horiguchi, J., Fujioka, C., Kiguchi, M., Yamamoto, H., Matsuura, N., Kitagawa, T., Teragawa, H., Kohno, N., & Ito, K. (2008) · Radiology · doi:10.1148/radiol.2482071804 · Cited by 293
Hadamitzky, M., Freißmuth, B., Meyer, T., Hein, F., Kastrati, A., Martinoff, S., Schömig, A., & Hausleiter, J. (2009) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2008.11.015 · Cited by 280
Self-citationSchuetz, G. M., Zacharopoulou, N. M., Schlattmann, P., & Dewey, M. (2010) · Annals of Internal Medicine · doi:10.7326/0003-4819-152-3-201002020-00008 · Cited by 265
Metadata
- Authors
- Hausleiter, J., Meyer, T., Hadamitzky, M., Zankl, M., Gerein, P., Dorrler, K., Kastrati, A., Martinoff, S., & Schomig, A.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-11-05
- Volume
- 28
- Issue
- 24
- Pages
- 3034-3041
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2132434940
- Cited by
- 138
- References
- 0
- FWCI
- 12.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Non-invasive coronary computed tomographic angiography for patients with suspected coronary artery disease: the Coronary Angiography by Computed Tomography with the Use of a Submillimeter resolution (CACTUS) trial. https://app.cochat.ai/papers/10.1093/eurheartj/ehm150
- The paper
- Hausleiter, J., Meyer, T., Hadamitzky, M., Zankl, M., Gerein, P., Dorrler, K., Kastrati, A., Martinoff, S., & Schomig, A. (2007). Non-invasive coronary computed tomographic angiography for patients with suspected coronary artery disease: the Coronary Angiography by Computed Tomography with the Use of a Submillimeter resolution (CACTUS) trial. European Heart Journal. https://doi.org/10.1093/eurheartj/ehm150
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.