The DOI matches its Crossref record; 103 of the 103 references it cites were found in a registry or an index.
Meta-analysis: Noninvasive Coronary Angiography Using Computed Tomography Versus Magnetic Resonance Imaging
Abstract
BACKGROUND: Two imaging techniques, multislice computed tomography (CT) and magnetic resonance imaging (MRI), have evolved for noninvasive coronary angiography. PURPOSE: To compare CT and MRI for ruling out clinically significant coronary artery disease (CAD) in adults with suspected or known CAD. DATA SOURCES: MEDLINE, EMBASE, and ISI Web of Science searches from inception through 2 June 2009 and bibliographies of reviews. STUDY SELECTION: Prospective English- or German-language studies that compared CT or MRI with conventional coronary angiography in all patients and included sufficient data for compilation of 2 x 2 tables. DATA EXTRACTION: 2 investigators independently extracted patient and study characteristics; differences were resolved by consensus. DATA SYNTHESIS: 89 and 20 studies (comprising 7516 and 989 patients) assessed CT and MRI, respectively. Bivariate analysis of data yielded a mean sensitivity and specificity of 97.2% (95% CI, 96.2% to 98.0%) and 87.4% (CI, 84.5% to 89.8%) for CT and 87.1% (CI, 83.0% to 90.3%) and 70.3% (CI, 58.8% to 79.7%) for MRI. In studies that included only patients with suspected CAD, sensitivity and specificity of CT were 97.6% (CI, 96.1% to 98.5%) and 89.2% (CI, 86.0% to 91.8%). Covariate analysis yielded a significantly higher sensitivity for CT scanners with more than 16 rows (98.1% [CI, 97.0% to 99.0%]; P < 0.050) than for older-generation scanners (95.6% [CI, 94.0% to 97.0%]). Heart rates less than 60 beats/min during CT yielded significantly better values for sensitivity than did higher heart rates (P < 0.001). LIMITATIONS: Few studies investigated coronary angiography with MRI. Only 5 studies were direct head-to-head comparisons of CT and MRI. Covariate analyses explained only part of the observed heterogeneity. CONCLUSION: For ruling out CAD, CT is more accurate than MRI. Scanners with more than 16 rows improve sensitivity, as do slowed heart rates. PRIMARY FUNDING SOURCE: None.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moher, D., Cook, D. J., Eastwood, S., Olkin, I., Rennie, D., & Stroup, D. F. (1999) · The Lancet · doi:10.1016/s0140-6736(99)04149-5 · Cited by 4,826
Writing Group Members, Rosamond, W., Flegal, K., Furie, K., Go, A., Greenlund, K., Haase, N., Hailpern, S. M., Ho, M., Howard, V., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.187998 · Cited by 3,711
Whiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Reitsma, J. B., Glas, A. S., Rutjes, A. W. S., Scholten, R. J. P. M., Bossuyt, P. M., & Zwinderman, A. H. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.02.022 · Cited by 3,369
Kim, R. J., Wu, E., Rafael, A., Chen, E.-L., Parker, M. A., Simonetti, O., Klocke, F. J., Bonow, R. O., & Judd, R. M. (2000) · New England Journal of Medicine · doi:10.1056/nejm200011163432003 · Cited by 3,306
Austen, W., Edwards, J., Frye, R., Gensini, G., Gott, V., Griffith, L., McGoon, D., Murphy, M., & Roe, B. (1975) · Circulation · doi:10.1161/01.cir.51.4.5 · Cited by 3,256
Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00010 · Cited by 3,219
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
Deeks, J. J., Macaskill, P., & Irwig, L. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.01.016 · Cited by 2,910
Cited by
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e3182776f83 · Cited by 2,410
Gersh, B. J., Maron, B. J., Bonow, R. O., Dearani, J. A., Fifer, M. A., Link, M. S., Naidu, S. S., Nishimura, R. A., Ommen, S. R., Rakowski, H., et al. (2011) · Circulation · doi:10.1161/cir.0b013e318223e2bd · Cited by 2,104
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.07.013 · Cited by 1,555
2011 ACCF/AHA Guideline for the Diagnosis and Treatment of Hypertrophic Cardiomyopathy
Gersh, B. J., Maron, B. J., Bonow, R. O., Dearani, J. A., Fifer, M. A., Link, M. S., Naidu, S. S., Nishimura, R. A., Ommen, S. R., Rakowski, H., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.06.011 · Cited by 1,276
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e318277d6a0 · Cited by 845
Metadata
- Authors
- Schuetz, G. M., Zacharopoulou, N. M., Schlattmann, P., & Dewey, M.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2010-02-02
- Volume
- 152
- Issue
- 3
- Pages
- 167-177
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2044767355
- Cited by
- 265
- References
- 103
- FWCI
- 30.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Meta-analysis: Noninvasive Coronary Angiography Using Computed Tomography Versus Magnetic Resonance Imaging. https://app.cochat.ai/papers/10.7326/0003-4819-152-3-201002020-00008
- The paper
- Schuetz, G. M., Zacharopoulou, N. M., Schlattmann, P., & Dewey, M. (2010). Meta-analysis: Noninvasive Coronary Angiography Using Computed Tomography Versus Magnetic Resonance Imaging. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-152-3-201002020-00008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.