Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 380

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Transcatheter closure of congenital ventricular septal defects: results of the European Registry

Carminati, M., Butera, G., Chessa, M., De Giovanni, J., Fisher, G., Gewillig, M., Peuster, M., Piechaud, J. F., Santoro, G., Sievert, H., Spadoni, I., Walsh, K., for the Investigators of the European VSD Registry · 2007 · European Heart Journal

Abstract

AIM: To report the experience of 23 tertiary referral European Centres on transcatheter closure of congenital ventricular septal defects (VSD). METHODS AND RESULTS: Implantation of transcatheter devices was attempted in 430 patients (pts) with congenital VSDs until July 2005. The following anatomic types were present: 119 muscular, 250 perimembranous, 16 multiple, 45 residual post-surgery. Median VSD size was 7 mm (range 3-22), fluoroscopy time 33 min (range 3-146). Devices implanted were Amplatzer muscular or membranous devices in 364, PDA devices in 12, ASD devices in seven, Starflex in seven, and coils in nine patients. Procedure was successful in 410 cases (95%). COMPLICATIONS: device embolization in five cases (surgery in two, catheter retrieval in three), aortic regurgitation in 14 cases (two of which requiring surgery), tricuspid regurgitation in 27 cases (no surgery was necessary), minor rhythm disturbances in 10 pts, death in one patient, complete heart block (cAVB) in 16 pts [perimembranous 12 of 250 (5%), muscular one of 119 (0.8%), residual post-surgery VSD three of 45 (6.7%)]. CAVB was transient in six patients, requiring permanent pace-makers in 10 cases (3.8%) (six early, four late). In the multivariate analysis, the only variable associated with a risk of the occurrence of complication was age (P=0.012) and weight (P=0.0035). In the univariate analysis, risk factors for the development of cAVB were, device type (P=0.03) and VSD location (P=0.05). After the multivariable Cox proportional hazards analysis, no risk factor was found. CONCLUSION: Transcatheter closure of congenital VSDs offers encouraging results. COMPLICATIONS are limited; the most relevant one seems to be the device related to cAVB in perimembranous VSD. More experience and long-term follow-up are mandatory to assess safety and effectiveness of this procedure as an alternative to conventional surgery.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehm314

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 380

Metadata

Authors
Carminati, M., Butera, G., Chessa, M., De Giovanni, J., Fisher, G., Gewillig, M., Peuster, M., Piechaud, J. F., Santoro, G., Sievert, H., Spadoni, I., Walsh, K., & for the Investigators of the European VSD Registry
Venue
European Heart Journal
Published
2007-05-04
Volume
28
Issue
19
Pages
2361-2368
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2165858244
Cited by
380
References
13
FWCI
10.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transcatheter closure of congenital ventricular septal defects: results of the European Registry. https://app.cochat.ai/papers/10.1093/eurheartj/ehm314
The paper
Carminati, M., Butera, G., Chessa, M., De Giovanni, J., Fisher, G., Gewillig, M., Peuster, M., Piechaud, J. F., Santoro, G., Sievert, H., Spadoni, I., Walsh, K., & for the Investigators of the European VSD Registry. (2007). Transcatheter closure of congenital ventricular septal defects: results of the European Registry. European Heart Journal. https://doi.org/10.1093/eurheartj/ehm314

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.