Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
AIMS: To determine the feasibility of prospective electrocardiogram (ECG)-gating to achieve low-dose computed tomography coronary angiography (CTCA). METHODS AND RESULTS: Forty-one consecutive patients with suspected (n = 35) or known coronary artery disease (n = 6) underwent 64-slice CTCA using prospective ECG-gating. Individual radiation dose exposure was estimated from the dose-length product. Two independent readers semi-quantitatively assessed the overall image quality on a five-point scale and measured vessel attenuation in each coronary segment. One patient was excluded for atrial fibrillation. Mean effective radiation dose was 2.1 +/- 0.6 mSv (range, 1.1-3.0 mSv). Image quality was inversely related to heart rate (HR) (57.3 +/- 6.2, range 39-66 b.p.m.; r = 0.58, P < 0.001), vessel attenuation (346 +/- 104, range 110-780 HU; r = 0.56, P < 0.001), and body mass index (26.1 +/- 4.0, range 19.1-36.3 kg/m(2); r = 0.45, P < 0.001), but not to HR variability (1.5 +/- 1.0, range 0.2-5.1 b.p.m.; r = 0.28, P = 0.069). Non-diagnostic CTCA image quality was found in 5.0% of coronary segments. However, below a HR of 63 b.p.m. (n = 28), as determined by receiver operator characteristic curve, only 1.1% of coronary segments were non-diagnostic compared with 14.8% with HR of >63 b.p.m. (P < 0.001). CONCLUSION: This first experience documents the feasibility of prospective ECG-gating for CTCA with diagnostic image quality at a low radiation dose (1.1-3.0 mSv), favouring HR <63 b.p.m.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Austen, W., Edwards, J., Frye, R., Gensini, G., Gott, V., Griffith, L., McGoon, D., Murphy, M., & Roe, B. (1975) · Circulation · doi:10.1161/01.cir.51.4.5 · Cited by 3,256
Diagnostic Accuracy of Noninvasive Coronary Angiography Using 64-Slice Spiral Computed Tomography
Raff, G. L., Gallagher, M. J., O’Neill, W. W., & Goldstein, J. A. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.05.056 · Cited by 1,472
Einstein, A. J., Henzlova, M. J., & Rajagopalan, S. (2007) · JAMA · doi:10.1001/jama.298.3.317 · Cited by 1,410
Budoff, M. J., Achenbach, S., Blumenthal, R. S., Carr, J. J., Goldin, J. G., Greenland, P., Guerci, A. D., Lima, J. A. C., Rader, D. J., Rubin, G. D., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178458 · Cited by 1,398
Authors/Task Force Members (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl001 · Cited by 1,336
Hendel, R. C., Patel, M. R., Kramer, C. M., Poon, M., Hendel, R. C., Carr, J. C., Gerstad, N. A., Gillam, L. D., Hodgson, J. M., Kim, R. J., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.003 · Cited by 1,288
Quantification of Obstructive and Nonobstructive Coronary Lesions by 64-Slice Computed Tomography
Leber, A. W., Knez, A., von Ziegler, F., Becker, A., Nikolaou, K., Paul, S., Wintersperger, B., Reiser, M., Becker, C. R., Steinbeck, G., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.03.071 · Cited by 1,109
Mollet, N. R., Cademartiri, F., van Mieghem, C. A. G., Runza, G., McFadden, E. P., Baks, T., Serruys, P. W., Krestin, G. P., & de Feyter, P. J. (2005) · Circulation · doi:10.1161/circulationaha.105.533471 · Cited by 1,018
Accuracy of MSCT coronary angiography with 64-slice technology: first experience
Leschka, S., Alkadhi, H., Plass, A., Desbiolles, L., Grünenfelder, J., Marincek, B., & Wildermuth, S. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi261 · Cited by 960
Radiation Dose to Patients From Cardiac Diagnostic Imaging
Einstein, A. J., Moser, K. W., Thompson, R. C., Cerqueira, M. D., & Henzlova, M. J. (2007) · Circulation · doi:10.1161/circulationaha.107.688101 · Cited by 806
Hausleiter, J., Meyer, T., Hadamitzky, M., Huber, E., Zankl, M., Martinoff, S., Kastrati, A., & Schömig, A. (2006) · Circulation · doi:10.1161/circulationaha.105.602490 · Cited by 705
Schuijf, J. D., Wijns, W., Jukema, J. W., Atsma, D. E., de Roos, A., Lamb, H. J., Stokkel, M. P. M., Dibbets-Schneider, P., Decramer, I., De Bondt, P., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.05.080 · Cited by 479
Scheffel, H., Alkadhi, H., Plass, A., Vachenauer, R., Desbiolles, L., Gaemperli, O., Schepis, T., Frauenfelder, T., Schertler, T., Husmann, L., et al. (2006) · European Radiology · doi:10.1007/s00330-006-0474-0 · Cited by 420
Self-citationMulkens, T. H., Bellinck, P., Baeyaert, M., Ghysen, D., Van Dijck, X., Mussen, E., Venstermans, C., & Termote, J.-L. (2005) · Radiology · doi:10.1148/radiol.2363041220 · Cited by 354
Step‐and‐shoot data acquisition and reconstruction for cardiac x‐ray computed tomography
Hsieh, J., Londt, J., Vass, M., Li, J., Tang, X., & Okerlund, D. (2006) · Medical Physics · doi:10.1118/1.2361078 · Cited by 228
Cardiac Image Fusion from Stand-Alone SPECT and CT: Clinical Experience
Gaemperli, O., Schepis, T., Valenta, I., Husmann, L., Scheffel, H., Duerst, V., Eberli, F. R., Lüscher, T. F., Alkadhi, H., & Kaufmann, P. A. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.037606 · Cited by 227
Self-citationRadiation dose estimates in dual-source computed tomography coronary angiography
Stolzmann, P., Scheffel, H., Schertler, T., Frauenfelder, T., Leschka, S., Husmann, L., Flohr, T. G., Marincek, B., Kaufmann, P. A., & Alkadhi, H. (2008) · European Radiology · doi:10.1007/s00330-007-0786-8 · Cited by 208
Self-citationIntegrated PET/CT for the assessment of coronary artery disease: a feasibility study.
Namdar, M., Hany, T. F., Koepfli, P., Siegrist, P. T., Burger, C., Wyss, C. A., Lüscher, T. F., von Schulthess, G. K., & Kaufmann, P. A. (2005) · PubMed · Cited by 194
Self-citationWintersperger, B. J., Nikolaou, K., von Ziegler, F., Johnson, T. R. C., Rist, C., Leber, A. W., Flohr, T. G., Knez, A., Reiser, M. F., & Becker, C. R. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000202639.99949.c6 · Cited by 194
(2007) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2007.05.034 · Cited by 185
Gaemperli, O., Schepis, T., Kalff, V., Namdar, M., Valenta, I., Stefani, L., Desbiolles, L. M., Leschka, S., Husmann, L., Alkadhi, H., et al. (2007) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-006-0342-9 · Cited by 151
Self-citationPET/CT: challenge for nuclear cardiology.
Schwaiger, M., Ziegler, S. I., & Nekolla, S. G. (2005) · PubMed · Cited by 140
Reply: Comparison of 64-Slice CT with Gated SPECT for Evaluation of Left Ventricular Function
Kaufmann, P. A., & Gaemperli, O. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.037457 · Cited by 77
Self-citationHoward, W. J. (2007) · Yearbook of Endocrinology · doi:10.1016/s0084-3741(08)70049-0 · Cited by 76
Comparison of 64-Slice CT with Gated SPECT for Evaluation of Left Ventricular Function
Dudley, N., & Kalirai, C. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.037333 · Cited by 52
Einfluss des Bodymass-Index auf den Kontrast in den Koronararterien mit der 64-Schicht-CT
Husmann, L., Leschka, S., Boehm, T., Desbiolles, L., Schepis, T., Koepfli, P., Gaemperli, O., Marinček, B., Kaufmann, P. A., & Alkadhi, H. (2006) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/s-2006-926871 · Cited by 40
Self-citationCT coronary angiography: where does it fit?
Carli, M. F. D. (2006) · PubMed · Cited by 8
Cited by
Motoyama, S., Sarai, M., Harigaya, H., Anno, H., Inoue, K., Hara, T., Naruse, H., Ishii, J., Hishida, H., Wong, N. D., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.02.068 · Cited by 1,433
Estimated Radiation Dose Associated With Cardiac CT Angiography
Hausleiter, J. (2009) · JAMA · doi:10.1001/jama.2009.54 · Cited by 1,000
Achenbach, S., Marwan, M., Ropers, D., Schepis, T., Pflederer, T., Anders, K., Kuettner, A., Daniel, W. G., Uder, M., & Lell, M. M. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehp470 · Cited by 585
Abbara, S., Arbab-Zadeh, A., Callister, T. Q., Desai, M. Y., Mamuya, W., Thomson, L., & Weigold, W. G. (2009) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2009.03.004 · Cited by 580
Initial evaluation of coronary images from 320-detector row computed tomography
Rybicki, F. J., Otero, H. J., Steigner, M. L., Vorobiof, G., Nallamshetty, L., Mitsouras, D., Ersoy, H., Mather, R. T., Judy, P. F., Cai, T., et al. (2008) · The International Journal of Cardiovascular Imaging · doi:10.1007/s10554-008-9308-2 · Cited by 563
Metadata
- Authors
- Husmann, L., Valenta, I., Gaemperli, O., Adda, O., Treyer, V., Wyss, C. A., Veit-Haibach, P., Tatsugami, F., von Schulthess, G. K., & Kaufmann, P. A.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-12-12
- Volume
- 29
- Issue
- 2
- Pages
- 191-197
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2113235311
- Cited by
- 530
- References
- 27
- FWCI
- 60.65
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.