Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
AIMS: To determine the feasibility of prospective electrocardiogram (ECG)-gating to achieve low-dose computed tomography coronary angiography (CTCA). METHODS AND RESULTS: Forty-one consecutive patients with suspected (n = 35) or known coronary artery disease (n = 6) underwent 64-slice CTCA using prospective ECG-gating. Individual radiation dose exposure was estimated from the dose-length product. Two independent readers semi-quantitatively assessed the overall image quality on a five-point scale and measured vessel attenuation in each coronary segment. One patient was excluded for atrial fibrillation. Mean effective radiation dose was 2.1 +/- 0.6 mSv (range, 1.1-3.0 mSv). Image quality was inversely related to heart rate (HR) (57.3 +/- 6.2, range 39-66 b.p.m.; r = 0.58, P < 0.001), vessel attenuation (346 +/- 104, range 110-780 HU; r = 0.56, P < 0.001), and body mass index (26.1 +/- 4.0, range 19.1-36.3 kg/m(2); r = 0.45, P < 0.001), but not to HR variability (1.5 +/- 1.0, range 0.2-5.1 b.p.m.; r = 0.28, P = 0.069). Non-diagnostic CTCA image quality was found in 5.0% of coronary segments. However, below a HR of 63 b.p.m. (n = 28), as determined by receiver operator characteristic curve, only 1.1% of coronary segments were non-diagnostic compared with 14.8% with HR of >63 b.p.m. (P < 0.001). CONCLUSION: This first experience documents the feasibility of prospective ECG-gating for CTCA with diagnostic image quality at a low radiation dose (1.1-3.0 mSv), favouring HR <63 b.p.m.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Austen, W., Edwards, J., Frye, R., Gensini, G., Gott, V., Griffith, L., McGoon, D., Murphy, M., & Roe, B. (1975) · Circulation · doi:10.1161/01.cir.51.4.5 · Cited by 3,256
Diagnostic Accuracy of Noninvasive Coronary Angiography Using 64-Slice Spiral Computed Tomography
Raff, G. L., Gallagher, M. J., O’Neill, W. W., & Goldstein, J. A. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.05.056 · Cited by 1,472
Einstein, A. J., Henzlova, M. J., & Rajagopalan, S. (2007) · JAMA · doi:10.1001/jama.298.3.317 · Cited by 1,410
Budoff, M. J., Achenbach, S., Blumenthal, R. S., Carr, J. J., Goldin, J. G., Greenland, P., Guerci, A. D., Lima, J. A. C., Rader, D. J., Rubin, G. D., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178458 · Cited by 1,398
Authors/Task Force Members (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl001 · Cited by 1,336
Hendel, R. C., Patel, M. R., Kramer, C. M., Poon, M., Hendel, R. C., Carr, J. C., Gerstad, N. A., Gillam, L. D., Hodgson, J. M., Kim, R. J., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.003 · Cited by 1,288
Quantification of Obstructive and Nonobstructive Coronary Lesions by 64-Slice Computed Tomography
Leber, A. W., Knez, A., von Ziegler, F., Becker, A., Nikolaou, K., Paul, S., Wintersperger, B., Reiser, M., Becker, C. R., Steinbeck, G., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.03.071 · Cited by 1,109
Mollet, N. R., Cademartiri, F., van Mieghem, C. A. G., Runza, G., McFadden, E. P., Baks, T., Serruys, P. W., Krestin, G. P., & de Feyter, P. J. (2005) · Circulation · doi:10.1161/circulationaha.105.533471 · Cited by 1,018
Accuracy of MSCT coronary angiography with 64-slice technology: first experience
Leschka, S., Alkadhi, H., Plass, A., Desbiolles, L., Grünenfelder, J., Marincek, B., & Wildermuth, S. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi261 · Cited by 960
Radiation Dose to Patients From Cardiac Diagnostic Imaging
Einstein, A. J., Moser, K. W., Thompson, R. C., Cerqueira, M. D., & Henzlova, M. J. (2007) · Circulation · doi:10.1161/circulationaha.107.688101 · Cited by 806
Cited by
Motoyama, S., Sarai, M., Harigaya, H., Anno, H., Inoue, K., Hara, T., Naruse, H., Ishii, J., Hishida, H., Wong, N. D., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.02.068 · Cited by 1,433
Estimated Radiation Dose Associated With Cardiac CT Angiography
Hausleiter, J. (2009) · JAMA · doi:10.1001/jama.2009.54 · Cited by 1,000
Achenbach, S., Marwan, M., Ropers, D., Schepis, T., Pflederer, T., Anders, K., Kuettner, A., Daniel, W. G., Uder, M., & Lell, M. M. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehp470 · Cited by 585
Abbara, S., Arbab-Zadeh, A., Callister, T. Q., Desai, M. Y., Mamuya, W., Thomson, L., & Weigold, W. G. (2009) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2009.03.004 · Cited by 580
Initial evaluation of coronary images from 320-detector row computed tomography
Rybicki, F. J., Otero, H. J., Steigner, M. L., Vorobiof, G., Nallamshetty, L., Mitsouras, D., Ersoy, H., Mather, R. T., Judy, P. F., Cai, T., et al. (2008) · The International Journal of Cardiovascular Imaging · doi:10.1007/s10554-008-9308-2 · Cited by 563
Coronary Computed Tomography Angiography for Early Triage of Patients With Acute Chest Pain
Hoffmann, U., Bamberg, F., Chae, C. U., Nichols, J. H., Rogers, I. S., Seneviratne, S. K., Truong, Q. A., Cury, R. C., Abbara, S., Shapiro, M. D., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.01.052 · Cited by 552
SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT
Halliburton, S. S., Abbara, S., Chen, M. Y., Gentry, R., Mahesh, M., Raff, G. L., Shaw, L. J., & Hausleiter, J. (2011) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2011.06.001 · Cited by 491
van Werkhoven, J. M., Schuijf, J. D., Gaemperli, O., Jukema, J. W., Boersma, E., Wijns, W., Stolzmann, P., Alkadhi, H., Valenta, I., Stokkel, M. P. M., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.10.043 · Cited by 336
Self-citationGeorge, R. T., Arbab-Zadeh, A., Miller, J. M., Kitagawa, K., Chang, H.-J., Bluemke, D. A., Becker, L., Yousuf, O., Texter, J., Lardo, A. C., et al. (2009) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.108.813766 · Cited by 324
Low-dose CT coronary angiography in the step-and-shoot mode: diagnostic performance
Scheffel, H., Alkadhi, H., Leschka, S., Plass, A., Desbiolles, L., Guber, I., Krauss, T., Gruenenfelder, J., Genoni, M., Luescher, T. F., et al. (2008) · Heart · doi:10.1136/hrt.2008.149971 · Cited by 291
Gentile, F., Castiglione, V., & De Caterina, R. (2021) · Circulation · doi:10.1161/circulationaha.121.055347 · Cited by 281
High-pitch spiral acquisition: A new scan mode for coronary CT angiography
Achenbach, S., Marwan, M., Schepis, T., Pflederer, T., Bruder, H., Allmendinger, T., Petersilka, M., Anders, K., Lell, M., Kuettner, A., et al. (2009) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2009.02.008 · Cited by 258
Image Quality and Radiation Exposure With a Low Tube Voltage Protocol for Coronary CT Angiography
Hausleiter, J., Martinoff, S., Hadamitzky, M., Martuscelli, E., Pschierer, I., Feuchtner, G. M., Catalán-Sanz, P., Czermak, B., Meyer, T. S., Hein, F., et al. (2010) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2010.08.016 · Cited by 233
“iagnostic information for most coronary CTA tudies, coronary CTA will contribute to the overall urden of medical radiation exposure (2).”
BackgroundRaff, G. L. (2009) · JAMA · doi:10.1001/jama.2009.814 · Cited by 233
Pundziute, G., Schuijf, J. D., Jukema, J. W., Decramer, I., Sarno, G., Vanhoenacker, P. K., Boersma, E., Reiber, J. H. C., Schalij, M. J., Wijns, W., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn356 · Cited by 232
SNMMI/ASNC/SCCT Guideline for Cardiac SPECT/CT and PET/CT 1.0
Dorbala, S., Di Carli, M. F., Delbeke, D., Abbara, S., DePuey, E. G., Dilsizian, V., Forrester, J., Janowitz, W., Kaufmann, P. A., Mahmarian, J., et al. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.105155 · Cited by 232
“Prospective triggering techniques reduce radiation dose (59,61,62).”
Self-citationChow, B. J. W., Small, G., Yam, Y., Chen, L., Achenbach, S., Al-Mallah, M., Berman, D. S., Budoff, M. J., Cademartiri, F., Callister, T. Q., et al. (2011) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.111.964155 · Cited by 222
Self-citationde Graaf, F. R., Schuijf, J. D., van Velzen, J. E., Kroft, L. J., de Roos, A., Reiber, J. H. C., Boersma, E., Schalij, M. J., Spano, F., Jukema, J. W., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehp571 · Cited by 200
“maximal dose reduction by using tube voltages with a maximum of 100 or 120 kV as well as performing image acquisition during a minimal phase window of only 75% of the cardiac cycle.(20,21) Other technical advances, such as adaptive collimation and highpitch spiral acquisition, may also allow significant radiation redu…”
Noninvasive Evaluation With Multislice Computed Tomography in Suspected Acute Coronary Syndrome
Henneman, M. M., Schuijf, J. D., Pundziute, G., van Werkhoven, J. M., van der Wall, E. E., Jukema, J. W., & Bax, J. J. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.04.012 · Cited by 189
Coronary CT angiography: current status and continuing challenges
Sun, Z., Choo, G. H., & Ng, K. H. (2012) · The British Journal of Radiology · doi:10.1259/bjr/15296170 · Cited by 189
On behalf of the Cardiovascular Committee of the EANM, T. E. A. T. E., Flotats, A., Knuuti, J., Gutberlet, M., Marcassa, C., Bengel, F. M., Kaufmann, P. A., Rees, M. R., & Hesse, B. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1586-y · Cited by 187
“Implementation of modern cardiac CT acquisition protocols such as prospective (step-andshoot) ECG triggering [89, 90], ECG-controlled current modulation (reduction of the tube current by 80% during systole) [42] and body mass-adapted tube voltage (reduction of the tube voltage to 100 kV in patients <90 kg of weight) […”
BackgroundSelf-citationMaruyama, T., Takada, M., Hasuike, T., Yoshikawa, A., Namimatsu, E., & Yoshizumi, T. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.07.048 · Cited by 175
Achenbach, S., Goroll, T., Seltmann, M., Pflederer, T., Anders, K., Ropers, D., Daniel, W. G., Uder, M., Lell, M., & Marwan, M. (2011) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2011.01.012 · Cited by 164
van Werkhoven, J. M., Schuijf, J. D., Gaemperli, O., Jukema, J. W., Kroft, L. J., Boersma, E., Pazhenkottil, A., Valenta, I., Pundziute, G., de Roos, A., et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp272 · Cited by 159
“Currently 64-slice MSCTA is still associated with a significantly higher radiation exposure than CS, although the radiation dose of MSCTA will decrease with the use of dedicated dose reduction techniques that have recently become available.(35-38)”
BackgroundSelf-citationvan Werkhoven, J. M., Gaemperli, O., Schuijf, J. D., Jukema, J. W., Kroft, L. J., Leschka, S., Alkadhi, H., Valenta, I., Pundziute, G., de Roos, A., et al. (2009) · Heart · doi:10.1136/hrt.2009.167353 · Cited by 52
Self-citationHoffmann, U., Truong, Q. A., Fleg, J. L., Goehler, A., Gazelle, S., Wiviott, S., Lee, H., Udelson, J. E., & Schoenfeld, D. (2012) · American Heart Journal · doi:10.1016/j.ahj.2012.01.028 · Cited by 43
Metadata
- Authors
- Husmann, L., Valenta, I., Gaemperli, O., Adda, O., Treyer, V., Wyss, C. A., Veit-Haibach, P., Tatsugami, F., von Schulthess, G. K., & Kaufmann, P. A.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-12-12
- Volume
- 29
- Issue
- 2
- Pages
- 191-197
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2113235311
- Cited by
- 530
- References
- 27
- FWCI
- 60.65
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).