Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
We evaluated the feasibility and image quality of a new scan mode for coronary computed tomography angiography (CTA) with an effective dose of less than 1 mSv. In 50 consecutive patients (body weight ≤ 100 kg, sinus rhythm ≤60 b.p.m. after pre-medication, coronary CTA was performed using a dual-source CT system with 2 × 128 × 0.6 mm collimation, 0.28 s rotation time, a pitch of 3.2 or 3.4, 100 kV tube voltage and current of 320 mA s. Data acquisition was prospectively triggered at 60% of the R–R interval and completed within one cardiac cycle. Image quality was evaluated using a four-point scale (1 = absence of any artefacts to 4 = uninterpretable). In all 50 patients, imaging was successful. Mean duration of data acquisition was 258 ± 20 ms. Mean dose-length product was 62 ± 5 mGy cm, the effective dose was 0.87 ± 0.07 mSv (0.78–0.99 mSv). Of the 742 coronary artery segments, 94% had an image quality score of 1, 5.0% a score of 2, 0.9% a score of 3, and 4 segments (0.5%) were ‘uninterpretable’. In non-obese patients with a low and stable heart rate, prospectively ECG-triggered high-pitch spiral coronary CTA provides excellent image quality at a consistent dose below 1.0 mSv.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
Gibbons, R. J., Abrams, J., Chatterjee, K., Daley, J., Deedwania, P. C., Douglas, J. S., Ferguson, T. B., Fihn, S. D., Fraker, T. D., Gardin, J. M., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02848-6 · Cited by 1,689
First performance evaluation of a dual-source CT (DSCT) system
Flohr, T. G., McCollough, C. H., Bruder, H., Petersilka, M., Gruber, K., Süβ, C., Grasruck, M., Stierstorfer, K., Krauss, B., Raupach, R., et al. (2006) · European Radiology · doi:10.1007/s00330-005-2919-2 · Cited by 1,413
Self-citationEinstein, A. J., Henzlova, M. J., & Rajagopalan, S. (2007) · JAMA · doi:10.1001/jama.298.3.317 · Cited by 1,410
Hendel, R. C., Patel, M. R., Kramer, C. M., Poon, M., Hendel, R. C., Carr, J. C., Gerstad, N. A., Gillam, L. D., Hodgson, J. M., Kim, R. J., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.003 · Cited by 1,288
Estimated Radiation Dose Associated With Cardiac CT Angiography
Hausleiter, J. (2009) · JAMA · doi:10.1001/jama.2009.54 · Cited by 1,000
SCCT guidelines for the interpretation and reporting of coronary computed tomographic angiography
Raff, G. L., Chair, Abidov, A., Achenbach, S., Berman, D. S., Boxt, L. M., Budoff, M. J., Cheng, V., DeFrance, T., Hellinger, J. C., et al. (2009) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2009.01.001 · Cited by 773
Self-citationEarls, J. P., Berman, E. L., Urban, B. A., Curry, C. A., Lane, J. L., Jennings, R. S., McCulloch, C. C., Hsieh, J., & Londt, J. H. (2008) · Radiology · doi:10.1148/radiol.2463070989 · Cited by 543
Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating
Husmann, L., Valenta, I., Gaemperli, O., Adda, O., Treyer, V., Wyss, C. A., Veit-Haibach, P., Tatsugami, F., von Schulthess, G. K., & Kaufmann, P. A. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm613 · Cited by 530
Fraker, T. D., Fihn, S. D., Writing on behalf of the 2002 Chronic Stable Angina Writing Committee, 2002 WRITING COMMITTEE MEMBERS, Gibbons, R. J., Abrams, J., Chatterjee, K., Daley, J., Deedwania, P. C., Douglas, J. S., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.187930 · Cited by 526
Cited by
Coronary CT Angiography versus Standard Evaluation in Acute Chest Pain
Hoffmann, U., Truong, Q. A., Schoenfeld, D. A., Chou, E. T., Woodard, P. K., Nagurney, J. T., Pope, J. H., Hauser, T. H., White, C. S., Weiner, S. G., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1201161 · Cited by 903
SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT
Halliburton, S. S., Abbara, S., Chen, M. Y., Gentry, R., Mahesh, M., Raff, G. L., Shaw, L. J., & Hausleiter, J. (2011) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2011.06.001 · Cited by 491
ICRP Publication 120: Radiological Protection in Cardiology
Cousins, C., Miller, D. L., Bernardi, G., Rehani, M. M., Schofield, P., Vañó, E., Einstein, A. J., Geiger, B., Heintz, P., Padovani, R., et al. (2013) · Annals of the ICRP · doi:10.1016/j.icrp.2012.09.001 · Cited by 428
JCS/JSCS 2020 Guideline on Diagnosis and Management of Cardiovascular Sequelae in Kawasaki Disease
Fukazawa, R., Kobayashi, J., Ayusawa, M., Hamada, H., Miura, M., Mitani, Y., Tsuda, E., Nakajima, H., Matsuura, H., Ikeda, K., et al. (2020) · Circulation Journal · doi:10.1253/circj.cj-19-1094 · Cited by 408
Verberne, H. J., Acampa, W., Anagnostopoulos, C., Ballinger, J., Bengel, F., De Bondt, P., Buechel, R. R., Cuocolo, A., van Eck-Smit, B. L. F., Flotats, A., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3139-x · Cited by 366
Moscariello, A., Takx, R. A. P., Schoepf, U. J., Renker, M., Zwerner, P. L., O’Brien, T. X., Allmendinger, T., Vogt, S., Schmidt, B., Savino, G., et al. (2011) · European Radiology · doi:10.1007/s00330-011-2164-9 · Cited by 276
Dose in x-ray computed tomography
Kalender, W. A. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/3/r129 · Cited by 235
“…today to quote effective dose values; interestingly, the quantity E used to specify dose is not even specified explicitly in many cases, e.g. ‘coronary CT with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition’ (Achenbach et al 2010).”
MethodIsrael, O., Pellet, O., Biassoni, L., De Palma, D., Estrada-Lobato, E., Gnanasegaran, G., Kuwert, T., la Fougère, C., Mariani, G., Massalha, S., et al. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-04404-6 · Cited by 225
Computational modeling of cardiac hemodynamics: Current status and future outlook
Mittal, R., Seo, J. H., Vedula, V., Choi, Y. J., Liu, H., Huang, H. H., Jain, S., Younes, L., Abraham, T., & George, R. T. (2016) · Journal of Computational Physics · doi:10.1016/j.jcp.2015.11.022 · Cited by 194
“Several systems are now capable of whole heart isotemporal acquisitions over portions of a single heartbeat [44, 45, 46].”
BackgroundCoronary CT angiography: current status and continuing challenges
Sun, Z., Choo, G. H., & Ng, K. H. (2012) · The British Journal of Radiology · doi:10.1259/bjr/15296170 · Cited by 189
“Increasing pitch to a higher value was made possible with the development of the second generation of DSCT scanners, Siemens’s Definition Flash (Siemens Healthcare, Erlangen, Germany), which enabled acquisition of 128 slices simultaneously (flying focal spot) [89, 90, 94, 40] (Table 2).”
InfluentialA review of patient dose and optimisation methods in adult and paediatric CT scanning
Dougeni, E., Faulkner, K., & Panayiotakis, G. (2012) · European Journal of Radiology · doi:10.1016/j.ejrad.2011.05.025 · Cited by 185
Renker, M., Nance, J. W., Schoepf, U. J., O’Brien, T. X., Zwerner, P. L., Meyer, M., Kerl, J. M., Bauer, R. W., Fink, C., Vogl, T. J., et al. (2011) · Radiology · doi:10.1148/radiol.11103574 · Cited by 182
Benz, D. C., Benetos, G., Rampidis, G., von Felten, E., Bakula, A., Sustar, A., Kudura, K., Messerli, M., Fuchs, T. A., Gebhard, C., et al. (2020) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2020.01.002 · Cited by 168
Lell, M. M., May, M., Deak, P., Alibek, S., Kuefner, M., Kuettner, A., Köhler, H., Achenbach, S., Uder, M., & Radkow, T. (2011) · Investigative Radiology · doi:10.1097/rli.0b013e3181f33b1d · Cited by 166
Self-citationAchenbach, S., Goroll, T., Seltmann, M., Pflederer, T., Anders, K., Ropers, D., Daniel, W. G., Uder, M., Lell, M., & Marwan, M. (2011) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2011.01.012 · Cited by 164
Self-citationRaff, G. L., Chinnaiyan, K. M., Cury, R. C., Garcia, M. T., Hecht, H. S., Hollander, J. E., O'Neil, B., Taylor, A. J., & Hoffmann, U. (2014) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2014.06.002 · Cited by 147
Metadata
- Authors
- Achenbach, S., Marwan, M., Ropers, D., Schepis, T., Pflederer, T., Anders, K., Kuettner, A., Daniel, W. G., Uder, M., & Lell, M. M.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-11-05
- Volume
- 31
- Issue
- 3
- Pages
- 340-346
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2029528527
- Cited by
- 585
- References
- 25
- FWCI
- 53.08
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.