Barlis, P., Regar, E., Serruys, P. W., Dimopoulos, K., van der Giessen, W. J., van Geuns, R.-J. M., Ferrante, G., Wandel, S., Windecker, S., van Es, G.-A., Eerdmans, P., Juni, P., di Mario, C. · 2010 · European Heart Journal

Abstract

AIMS: Incomplete endothelialization has been found to be associated with late stent thrombosis, a rare but devastating phenomenon, more frequent after drug-eluting stent implantation. Optical coherence tomography (OCT) has 10 times greater resolution than intravascular ultrasound and thus appears to be a valuable modality for the assessment of stent strut coverage. The LEADERS trial was a multi-centre, randomized comparison of a biolimus-eluting stent (BES) with biodegradable polymer with a sirolimus-eluting stent (SES) using a durable polymer. This study sought to evaluate tissue coverage and apposition of stents using OCT in a group of patients from the randomized LEADERS trial. METHODS AND RESULTS: Fifty-six consecutive patients underwent OCT during angiographic follow-up at 9 months. OCT images were acquired using a non-occlusive technique at a pullback speed of 3 mm/s. Data were analysed using a Bayesian hierarchical random-effects model, which accounted for the correlation of lesion characteristics within patients and implicitly assigned analytical weights to each lesion depending on the number of struts observed per lesion. Primary outcome was the difference in percentage of uncovered struts between BESs and SESs. Twenty patients were included in the analysis in the BES group (29 lesions with 4592 struts) and 26 patients in the SES group (35 lesions with 6476 struts). A total of 83 struts were uncovered in the BES group and 407 out of 6476 struts were uncovered in the SES group [weighted difference -1.4%, 95% confidence interval (CI) -3.7 to 0.0, P = 0.04]. Results were similar after adjustment for pre-procedure lesion length, reference vessel diameter, number of implanted study stents, and presence of stent overlap. There were three lesions in the BES group and 15 lesions in the SES group that had > or =5% of all struts uncovered (difference -33.1%, 95% CI -61.7 to -10.3, P < 0.01). CONCLUSION: Strut coverage at an average follow-up of 9 months appears to be more complete in patients allocated to BESs when compared with SESs. The impact of this difference on clinical outcome and, in particular, on the risk of late stent thrombosis is yet to be determined.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehp480

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 248

Metadata

Authors
Barlis, P., Regar, E., Serruys, P. W., Dimopoulos, K., van der Giessen, W. J., van Geuns, R.-J. M., Ferrante, G., Wandel, S., Windecker, S., van Es, G.-A., Eerdmans, P., Juni, P., & di Mario, C.
Venue
European Heart Journal
Published
2009-11-04
Volume
31
Issue
2
Pages
165-176
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2152264499
Cited by
248
References
1
FWCI
26.76
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An optical coherence tomography study of a biodegradable vs. durable polymer-coated limus-eluting stent: a LEADERS trial sub-study. https://app.cochat.ai/papers/10.1093/eurheartj/ehp480
The paper
Barlis, P., Regar, E., Serruys, P. W., Dimopoulos, K., van der Giessen, W. J., van Geuns, R.-J. M., Ferrante, G., Wandel, S., Windecker, S., van Es, G.-A., Eerdmans, P., Juni, P., & di Mario, C. (2010). An optical coherence tomography study of a biodegradable vs. durable polymer-coated limus-eluting stent: a LEADERS trial sub-study. European Heart Journal. https://doi.org/10.1093/eurheartj/ehp480

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).