Abstract
AIMS: Incomplete endothelialization has been found to be associated with late stent thrombosis, a rare but devastating phenomenon, more frequent after drug-eluting stent implantation. Optical coherence tomography (OCT) has 10 times greater resolution than intravascular ultrasound and thus appears to be a valuable modality for the assessment of stent strut coverage. The LEADERS trial was a multi-centre, randomized comparison of a biolimus-eluting stent (BES) with biodegradable polymer with a sirolimus-eluting stent (SES) using a durable polymer. This study sought to evaluate tissue coverage and apposition of stents using OCT in a group of patients from the randomized LEADERS trial. METHODS AND RESULTS: Fifty-six consecutive patients underwent OCT during angiographic follow-up at 9 months. OCT images were acquired using a non-occlusive technique at a pullback speed of 3 mm/s. Data were analysed using a Bayesian hierarchical random-effects model, which accounted for the correlation of lesion characteristics within patients and implicitly assigned analytical weights to each lesion depending on the number of struts observed per lesion. Primary outcome was the difference in percentage of uncovered struts between BESs and SESs. Twenty patients were included in the analysis in the BES group (29 lesions with 4592 struts) and 26 patients in the SES group (35 lesions with 6476 struts). A total of 83 struts were uncovered in the BES group and 407 out of 6476 struts were uncovered in the SES group [weighted difference -1.4%, 95% confidence interval (CI) -3.7 to 0.0, P = 0.04]. Results were similar after adjustment for pre-procedure lesion length, reference vessel diameter, number of implanted study stents, and presence of stent overlap. There were three lesions in the BES group and 15 lesions in the SES group that had > or =5% of all struts uncovered (difference -33.1%, 95% CI -61.7 to -10.3, P < 0.01). CONCLUSION: Strut coverage at an average follow-up of 9 months appears to be more complete in patients allocated to BESs when compared with SESs. The impact of this difference on clinical outcome and, in particular, on the risk of late stent thrombosis is yet to be determined.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pathology of Drug-Eluting Stents in Humans
Joner, M., Finn, A. V., Farb, A., Mont, E. K., Kolodgie, F. D., Ladich, E., Kutys, R., Skorija, K., Gold, H. K., & Virmani, R. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.03.042 · Cited by 2,744 · cited 2×
“Struts directly exposed to the blood flow may be surrogates for thrombotic risk given that pathological studies have identified a lack of tissue healing in cases of stent thrombosis.(6,22) Furthermore, exposed struts, particularly if malapposed, are also likely to result in flow disturbance that can be pro-thrombotic.”
BackgroundWRITING COMMITTEE MEMBERS, Smith, S. C., Feldman, T. E., Hirshfeld, J. W., Jacobs, A. K., Kern, M. J., King, S. B., Morrison, D. A., O’Neill, W. W., Schaff, H. V., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.170815 · Cited by 2,218
Bayesian Approaches to Clinical Trials and Health‐Care Evaluation
Spiegelhalter, D. J., Abrams, K. R., & Myles, J. P. (2003) · Wiley eBooks · doi:10.1002/0470092602 · Cited by 1,673
Images in Cardiovascular Medicine
(2012) · Wilderness & Environmental Medicine · doi:10.1016/j.wem.2012.05.013 · Cited by 1,519
Outcomes associated with drug-eluting and bare-metal stents: a collaborative network meta-analysis
Stettler, C., Wandel, S., Allemann, S., Kastrati, A., Morice, M. C., Schömig, A., Pfisterer, M. E., Stone, G. W., Leon, M. B., de Lezo, J. S., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61444-5 · Cited by 1,428
Self-citationFinn, A. V., Joner, M., Nakazawa, G., Kolodgie, F., Newell, J., John, M. C., Gold, H. K., & Virmani, R. (2007) · Circulation · doi:10.1161/circulationaha.107.693739 · Cited by 1,277 · cited 2×
“Only one autopsy study convincingly linked stent coverage and thrombosis.(6) This study did not offer a cut-off percentage of uncovered stents associated with stent thrombosis and focused on the prevalence of uncovered struts in individual cross-sections (information we also convey in Figure 3).”
BackgroundThe Dynamic Response of Vascular Endothelial Cells to Fluid Shear Stress
Dewey, C. F., Bussolari, S. R., Gimbrone, M. A., & Davies, P. F. (1981) · Journal of Biomechanical Engineering · doi:10.1115/1.3138276 · Cited by 1,136
King, S. B., Smith, S. C., Hirshfeld, J. W., Jacobs, A. K., Morrison, D. A., Williams, D. O., 2005 WRITING COMMITTEE MEMBERS, Smith, S. C., Feldman, T. E., Hirshfeld, J. W., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.188208 · Cited by 1,014
Vascular Responses to Drug Eluting Stents: Importance of Delayed Healing
Finn, A. V., Nakazawa, G., Joner, M., Kolodgie, F. D., Mont, E. K., Gold, H. K., & Virmani, R. (2007) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.107.144220 · Cited by 900
Windecker, S., Serruys, P. W., Wandel, S., Buszman, P., Trznadel, S., Linke, A., Lenk, K., Ischinger, T., Klauss, V., Eberli, F., et al. (2008) · The Lancet · doi:10.1016/s0140-6736(08)61244-1 · Cited by 653 · cited 3×
“20), respectively.(11) Durable polymer surface coatings may be one of the causes for incomplete endothelialization of first-generation DESs.”
BackgroundMethodInfluentialSelf-citation2007 Focused Update of the ACC/AHA/SCAI 2005 Guideline Update for Percutaneous Coronary Intervention
King, S. B., Smith, S. C., Hirshfeld, J. W., Morrison, D. A., Williams, D. O., & Jacobs, A. K. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.10.002 · Cited by 612
Sirolimus-Eluting and Paclitaxel-Eluting Stents for Coronary Revascularization
Windecker, S., Remondino, A., Eberli, F. R., Jüni, P., Räber, L., Wenaweser, P., Togni, M., Billinger, M., Tüller, D., Seiler, C., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa051175 · Cited by 593
Self-citationPaclitaxel-Eluting or Sirolimus-Eluting Stents to Prevent Restenosis in Diabetic Patients
Dibra, A., Kastrati, A., Mehilli, J., Pache, J., Schühlen, H., von Beckerath, N., Ulm, K., Wessely, R., Dirschinger, J., & Schömig, A. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa044372 · Cited by 523
A Paclitaxel-Eluting Stent for the Prevention of Coronary Restenosis
Park, S.-J., Shim, W. H., Ho, D. S., Raizner, A. E., Park, S.-W., Hong, M.-K., Lee, C. W., Choi, D., Jang, Y., Lam, R., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa021007 · Cited by 456
Stettler, C., Allemann, S., Wandel, S., Kastrati, A., Morice, M. C., Schomig, A., Pfisterer, M. E., Stone, G. W., Leon, M. B., Lezo, J. S. D., et al. (2008) · BMJ · doi:10.1136/bmj.a1331 · Cited by 320 · cited 2×
“19), suggesting similar efficacy in preventing restenosis to SESs, as confirmed by the results of the main study.(8) The BES contained fewer exposed stent struts, which translated into more than 95% of the stents showing near-complete coverage vs.”
ResultSelf-citationKastrati, A., Dibra, A., Eberle, S., Mehilli, J., Suárez de Lezo, J., Goy, J.-J., Ulm, K., & Schömig, A. (2005) · JAMA · doi:10.1001/jama.294.7.819 · Cited by 282
From Bench to Bedside A Novel Technique of Acquiring OCT Images
Prati, F., Cera, M., Ramazzotti, V., Imola, F., Giudice, R., Giudice, M., Propris, S. D., & Albertucci, M. (2008) · Circulation Journal · doi:10.1253/circj.72.839 · Cited by 254
Kastrati, A., Dibra, A., & Eberle, S. (2005) · ACC Current Journal Review · doi:10.1016/j.accreview.2005.10.047 · Cited by 235
Shear Stress Biology of the Endothelium
Davies, P. F., Spaan, J. A., & Krams, R. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-8774-0 · Cited by 201 · cited 1×
“Furthermore, exposed struts, particularly if malapposed, are also likely to result in flow disturbance that can be pro-thrombotic.(23,24) The polymer coating as a system for drug delivery has been implicated as being pro-inflammatory and retard healing and coverage.”
BackgroundBarlis, P., Dimopoulos, K., Tanigawa, J., Dzielicka, E., Ferrante, G., Furia, F. D., & Mario, C. D. (2009) · International Journal of Cardiology · doi:10.1016/j.ijcard.2008.11.204 · Cited by 59
Self-citation
Cited by
Garg, S., & Serruys, P. W. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.06.007 · Cited by 501
Self-citationPrati, F., Guagliumi, G., Mintz, G. S., Costa, M., Regar, E., Akasaka, T., Barlis, P., Tearney, G. J., Jang, I.-K., Arbustini, E., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs095 · Cited by 400
Self-citationStefanini, G. G., Byrne, R. A., Serruys, P. W., de Waha, A., Meier, B., Massberg, S., Juni, P., Schomig, A., Windecker, S., & Kastrati, A. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs086 · Cited by 384
Self-citationStefanini, G. G., Kalesan, B., Serruys, P. W., Heg, D., Buszman, P., Linke, A., Ischinger, T., Klauss, V., Eberli, F., Wijns, W., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(11)61672-3 · Cited by 354
Self-citationTada, T., Byrne, R. A., Simunovic, I., King, L. A., Cassese, S., Joner, M., Fusaro, M., Schneider, S., Schulz, S., Ibrahim, T., et al. (2013) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2013.06.015 · Cited by 342
Metadata
- Authors
- Barlis, P., Regar, E., Serruys, P. W., Dimopoulos, K., van der Giessen, W. J., van Geuns, R.-J. M., Ferrante, G., Wandel, S., Windecker, S., van Es, G.-A., Eerdmans, P., Juni, P., & di Mario, C.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-11-04
- Volume
- 31
- Issue
- 2
- Pages
- 165-176
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2152264499
- Cited by
- 248
- References
- 20
- FWCI
- 26.76
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.