The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Tissue Doppler E/E' ratio is a powerful predictor of primary cardiac events in a hypertensive population: an ASCOT substudy
Open accessAbstract
AIMS: Patients with controlled hypertension are at risk of future cardiac events, but predicting first events remains difficult. We hypothesized that modern echocardiographic measures of left ventricular diastolic function may be more sensitive than traditional echocardiographic methods of risk prediction and set out to test this in a cohort of patients with well-controlled hypertension. METHODS AND RESULTS: Conventional and tissue Doppler echocardiography was performed on 980 participants in the Anglo-Scandinavian Cardiac Outcomes Trial (ASCOT). All subjects had hypertension, but no known cardiac disease. Cardiac events were defined as fatal and non-fatal myocardial infarction (including silent myocardial infarction), coronary revascularization procedures, new-onset angina (stable or unstable), fatal and non-fatal heart failure, and life-threatening arrhythmias. Analysis was performed by a single, blinded observer. There were 56 primary cardiac events during 4.2 +/- 0.7 years follow-up. The ratio of transmitral Doppler early filling velocity to tissue Doppler early diastolic mitral annular velocity (E/E') was the strongest predictor of first cardiac events in Cox-proportional hazards models. Following adjustment for covariates, a unit rise in the E/E' ratio was associated with a 17% increment in risk of a cardiac event (HR 1.17, CI 1.05-1.29; P = 0.003). CONCLUSION: Tissue Doppler E/E', a non-invasive estimate of left atrial filling pressure, independently predicts primary cardiac events in a hypertensive population and out-performed traditional echocardiographic measures in this moderately sized, well-treated hypertensive population. E/E' represents a simple, effective tool for assessing cardiac risk in a hypertensive population.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Lang, R. M., Bierig, M., Devereux, R. B., Flachskampf, F. A., Foster, E., Pellikka, P. A., Picard, M. H., Roman, M. J., Seward, J., Shanewise, J. S., et al. (2005) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2005.10.005 · Cited by 11,318
Levy, D., Garrison, R. J., Savage, D. D., Kannel, W. B., & Castelli, W. P. (1990) · New England Journal of Medicine · doi:10.1056/nejm199005313222203 · Cited by 5,699
(1997) · Archives of Internal Medicine · doi:10.1001/archinte.1997.00440420033005 · Cited by 3,777
Ommen, S. R., Nishimura, R. A., Appleton, C. P., Miller, F. A., Oh, J. K., Redfield, M. M., & Tajik, A. J. (2000) · Circulation · doi:10.1161/01.cir.102.15.1788 · Cited by 2,790
Cited by
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht151 · Cited by 13,655
Mancia, G., Fagard, R., Narkiewicz, K., Redón, J., Zanchetti, A., Böhm, M., Christiaens, T., Cifkova, R., De Backer, G., Dominiczak, A., et al. (2013) · Journal of Hypertension · doi:10.1097/01.hjh.0000431740.32696.cc · Cited by 5,655
Lurbe, E., Agabiti-Rosei, E., Cruickshank, J. K., Dominiczak, A., Erdine, S., Hirth, A., Invitti, C., Litwin, M., Mancia, G., Pall, D., et al. (2016) · Journal of Hypertension · doi:10.1097/hjh.0000000000001039 · Cited by 1,379
Galderisi, M., Cosyns, B., Edvardsen, T., Cardim, N., Delgado, V., Di Salvo, G., Donal, E., Sade, L. E., Ernande, L., Garbi, M., et al. (2017) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jex244 · Cited by 846
Daskalopoulou, S. S., Rabi, D. M., Zarnke, K. B., Dasgupta, K., Nerenberg, K., Cloutier, L., Gelfer, M., Lamarre-Cliche, M., Milot, A., Bolli, P., et al. (2015) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2015.02.016 · Cited by 684
Metadata
- Authors
- Sharp, A. S. P., Tapp, R. J., Thom, S. A. M., Francis, D. P., Hughes, A. D., Stanton, A. V., Zambanini, A., O'Brien, E., Chaturvedi, N., Lyons, S., Byrd, S., Poulter, N. R., Sever, P. S., Mayet, J., & on behalf of the ASCOT Investigators
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-11-26
- Volume
- 31
- Issue
- 6
- Pages
- 747-752
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2099614776
- Cited by
- 208
- References
- 5
- FWCI
- 4.55
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tissue Doppler E/E' ratio is a powerful predictor of primary cardiac events in a hypertensive population: an ASCOT substudy. https://app.cochat.ai/papers/10.1093/eurheartj/ehp498
- The paper
- Sharp, A. S. P., Tapp, R. J., Thom, S. A. M., Francis, D. P., Hughes, A. D., Stanton, A. V., Zambanini, A., O'Brien, E., Chaturvedi, N., Lyons, S., Byrd, S., Poulter, N. R., Sever, P. S., Mayet, J., & on behalf of the ASCOT Investigators. (2010). Tissue Doppler E/E' ratio is a powerful predictor of primary cardiac events in a hypertensive population: an ASCOT substudy. European Heart Journal. https://doi.org/10.1093/eurheartj/ehp498
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.