The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Transcatheter aortic valve implantation: role of multi-detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve function
Abstract
AIMS: Aortic regurgitation after transcatheter aortic valve implantation (TAVI) is one of the most frequent complications. However, the underlying mechanisms of this complication remain unclear. The present evaluation studied the anatomic and morphological features of the aortic valve annulus that may predict aortic regurgitation after TAVI. METHODS AND RESULTS: In 53 patients with severe aortic stenosis undergoing TAVI, multi-detector row computed tomography (MDCT) assessment of the aortic valve apparatus was performed. For aortic valve annulus sizing, two orthogonal diameters were measured (coronal and sagittal). In addition, the extent of valve calcifications was quantified. At 1-month follow-up after procedure, MDCT was repeated to evaluate and correlate the prosthesis deployment to the presence of aortic regurgitation. Successful procedure was achieved in 48 (91%) patients. At baseline, MDCT demonstrated an ellipsoid shape of the aortic valve annulus with significantly larger coronal diameter when compared with sagittal diameter (25.1 +/- 2.4 vs. 22.9 +/- 2.0 mm, P < 0.001). At follow-up, MDCT showed a non-circular deployment of the prosthesis in six (14%) patients. Moderate post-procedural aortic regurgitation was observed in five (11%) patients. These patients showed significantly larger aortic valve annulus (27.3 +/- 1.6 vs. 24.8 +/- 2.4 mm, P = 0.007) and more calcified native valves (4174 +/- 1604 vs. 2444 +/- 1237 HU, P = 0.005) at baseline and less favourable deployment of the prosthesis after TAVI. CONCLUSION: Multi-detector row computed tomography enables an accurate sizing of the aortic valve annulus and constitutes a valuable imaging tool to evaluate prosthesis location and deployment after TAVI. In addition, MDCT helps to understand the underlying mechanisms of post-procedural aortic regurgitation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frailty in Older Adults: Evidence for a Phenotype
Fried, L. P., Tangen, C. M., Walston, J., Newman, A. B., Hirsch, C., Gottdiener, J., Seeman, T., Tracy, R., Kop, W. J., Burke, G., et al. (2001) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/56.3.m146 · Cited by 24,907
Lang, R. M., Bierig, M., Devereux, R. B., Flachskampf, F. A., Foster, E., Pellikka, P. A., Picard, M. H., Roman, M. J., Seward, J., Shanewise, J. S., et al. (2005) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2005.10.005 · Cited by 11,318
Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice
Baumgartner, H., Hung, J., Bermejo, J., Chambers, J. B., Evangelista, A., Griffin, B. P., Iung, B., Otto, C. M., Pellikka, P. A., & Quinones, M. (2009) · European Journal of Echocardiography · doi:10.1093/ejechocard/jen303 · Cited by 967
Cited by
Lang, R. M., Badano, L. P., Mor-Avi, V., Afilalo, J., Armstrong, A., Ernande, L., Flachskampf, F. A., Foster, E., Goldstein, S. A., Kuznetsova, T., et al. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.10.003 · Cited by 12,362
Lang, R. M., Badano, L. P., Mor-Avi, V., Afilalo, J., Armstrong, A., Ernande, L., Flachskampf, F. A., Foster, E., Goldstein, S. A., Kuznetsova, T., et al. (2015) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jev014 · Cited by 8,361
2012 ACCF/AATS/SCAI/STS Expert Consensus Document on Transcatheter Aortic Valve Replacement
Holmes, D. R., Mack, M. J., Kaul, S., Agnihotri, A., Alexander, K. P., Bailey, S. R., Calhoon, J. H., Carabello, B. A., Desai, M. Y., Edwards, F. H., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.01.001 · Cited by 749
Achenbach, S., Delgado, V., Hausleiter, J., Schoenhagen, P., Min, J. K., & Leipsic, J. A. (2012) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2012.11.002 · Cited by 634
Self-citationJilaihawi, H., Kashif, M., Fontana, G., Furugen, A., Shiota, T., Friede, G., Makhija, R., Doctor, N., Leon, M. B., & Makkar, R. R. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.11.045 · Cited by 480
Metadata
- Authors
- Delgado, V., Ng, A. C. T., van de Veire, N. R., van der Kley, F., Schuijf, J. D., Tops, L. F., de Weger, A., Tavilla, G., de Roos, A., Kroft, L. J., Schalij, M. J., & Bax, J. J.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-02-19
- Volume
- 31
- Issue
- 9
- Pages
- 1114-1123
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2098094997
- Cited by
- 242
- References
- 3
- FWCI
- 21.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transcatheter aortic valve implantation: role of multi-detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve function. https://app.cochat.ai/papers/10.1093/eurheartj/ehq018
- The paper
- Delgado, V., Ng, A. C. T., van de Veire, N. R., van der Kley, F., Schuijf, J. D., Tops, L. F., de Weger, A., Tavilla, G., de Roos, A., Kroft, L. J., Schalij, M. J., & Bax, J. J. (2010). Transcatheter aortic valve implantation: role of multi-detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve function. European Heart Journal. https://doi.org/10.1093/eurheartj/ehq018
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.