CoChat

Transcatheter aortic valve implantation: role of multi-detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve function

Delgado, V., Ng, A. C. T., van de Veire, N. R., van der Kley, F., Schuijf, J. D., Tops, L. F., de Weger, A., Tavilla, G., de Roos, A., Kroft, L. J., Schalij, M. J., Bax, J. J. · 2010 · European Heart Journal
Cited by 242

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Abstract

AIMS: Aortic regurgitation after transcatheter aortic valve implantation (TAVI) is one of the most frequent complications. However, the underlying mechanisms of this complication remain unclear. The present evaluation studied the anatomic and morphological features of the aortic valve annulus that may predict aortic regurgitation after TAVI. METHODS AND RESULTS: In 53 patients with severe aortic stenosis undergoing TAVI, multi-detector row computed tomography (MDCT) assessment of the aortic valve apparatus was performed. For aortic valve annulus sizing, two orthogonal diameters were measured (coronal and sagittal). In addition, the extent of valve calcifications was quantified. At 1-month follow-up after procedure, MDCT was repeated to evaluate and correlate the prosthesis deployment to the presence of aortic regurgitation. Successful procedure was achieved in 48 (91%) patients. At baseline, MDCT demonstrated an ellipsoid shape of the aortic valve annulus with significantly larger coronal diameter when compared with sagittal diameter (25.1 +/- 2.4 vs. 22.9 +/- 2.0 mm, P < 0.001). At follow-up, MDCT showed a non-circular deployment of the prosthesis in six (14%) patients. Moderate post-procedural aortic regurgitation was observed in five (11%) patients. These patients showed significantly larger aortic valve annulus (27.3 +/- 1.6 vs. 24.8 +/- 2.4 mm, P = 0.007) and more calcified native valves (4174 +/- 1604 vs. 2444 +/- 1237 HU, P = 0.005) at baseline and less favourable deployment of the prosthesis after TAVI. CONCLUSION: Multi-detector row computed tomography enables an accurate sizing of the aortic valve annulus and constitutes a valuable imaging tool to evaluate prosthesis location and deployment after TAVI. In addition, MDCT helps to understand the underlying mechanisms of post-procedural aortic regurgitation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehq018

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 242

Metadata

Authors
Delgado, V., Ng, A. C. T., van de Veire, N. R., van der Kley, F., Schuijf, J. D., Tops, L. F., de Weger, A., Tavilla, G., de Roos, A., Kroft, L. J., Schalij, M. J., & Bax, J. J.
Venue
European Heart Journal
Published
2010-02-19
Volume
31
Issue
9
Pages
1114-1123
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2098094997
Cited by
242
References
22
FWCI
21.46
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.