Transcatheter aortic valve implantation: role of multi-detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve function
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
AIMS: Aortic regurgitation after transcatheter aortic valve implantation (TAVI) is one of the most frequent complications. However, the underlying mechanisms of this complication remain unclear. The present evaluation studied the anatomic and morphological features of the aortic valve annulus that may predict aortic regurgitation after TAVI. METHODS AND RESULTS: In 53 patients with severe aortic stenosis undergoing TAVI, multi-detector row computed tomography (MDCT) assessment of the aortic valve apparatus was performed. For aortic valve annulus sizing, two orthogonal diameters were measured (coronal and sagittal). In addition, the extent of valve calcifications was quantified. At 1-month follow-up after procedure, MDCT was repeated to evaluate and correlate the prosthesis deployment to the presence of aortic regurgitation. Successful procedure was achieved in 48 (91%) patients. At baseline, MDCT demonstrated an ellipsoid shape of the aortic valve annulus with significantly larger coronal diameter when compared with sagittal diameter (25.1 +/- 2.4 vs. 22.9 +/- 2.0 mm, P < 0.001). At follow-up, MDCT showed a non-circular deployment of the prosthesis in six (14%) patients. Moderate post-procedural aortic regurgitation was observed in five (11%) patients. These patients showed significantly larger aortic valve annulus (27.3 +/- 1.6 vs. 24.8 +/- 2.4 mm, P = 0.007) and more calcified native valves (4174 +/- 1604 vs. 2444 +/- 1237 HU, P = 0.005) at baseline and less favourable deployment of the prosthesis after TAVI. CONCLUSION: Multi-detector row computed tomography enables an accurate sizing of the aortic valve annulus and constitutes a valuable imaging tool to evaluate prosthesis location and deployment after TAVI. In addition, MDCT helps to understand the underlying mechanisms of post-procedural aortic regurgitation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frailty in Older Adults: Evidence for a Phenotype
Fried, L. P., Tangen, C. M., Walston, J., Newman, A. B., Hirsch, C., Gottdiener, J., Seeman, T., Tracy, R., Kop, W. J., Burke, G., et al. (2001) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/56.3.m146 · Cited by 24,907 · cited 2×
“The clinical evaluation consisted of risk assessment based on the logEuroSCORE,(10) associated comorbidities not accounted for in the score and frailty condition defined according to the criteria of Fried et al.(11) In addition, comprehensive evaluation of aortic valve anatomy and function with transthoracic echocardi…”
MethodLang, R. M., Bierig, M., Devereux, R. B., Flachskampf, F. A., Foster, E., Pellikka, P. A., Picard, M. H., Roman, M. J., Seward, J., Shanewise, J. S., et al. (2005) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2005.10.005 · Cited by 11,318 · cited 2×
“Left ventricular outflow tract diameter and aortic annulus, sinus and sinotubular junction diameters were measured at the parasternal long-axis view.(12) Continuous-wave Doppler recordings through the aortic valve were obtained and peak and mean transaortic pressure gradients were calculated.”
MethodBonow, R. O., Carabello, B. A., Chatterjee, K., de Leon, A. C., Faxon, D. P., Freed, M. D., Gaasch, W. H., Lytle, B. W., Nishimura, R. A., O’Gara, P. T., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.176857 · Cited by 8,495
Zoghbi, W. A., Enriquez-Sarano, M., Foster, E., Grayburn, P. A., Kraft, C. D., Levine, R. A., Nihoyannopoulos, P., Otto, C. M., Quinones, M. A., Rakowski, H., et al. (2003) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(03)00335-3 · Cited by 4,044
Authors/Task Force Members, Vahanian, A., Baumgartner, H., Bax, J., Butchart, E., Dion, R., Filippatos, G., Flachskampf, F., Hall, R., Iung, B., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl428 · Cited by 3,593
Self-citationEuropean system for cardiac operative risk evaluation (EuroSCORE)
Nashef, S. A. M., Roques, F., Michel, P., Gauducheau, E., Lemeshow, S., & Salamon, R. (1999) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/s1010-7940(99)00134-7 · Cited by 3,362
Webb, J. G., Pasupati, S., Humphries, K., Thompson, C., Altwegg, L., Moss, R., Sinhal, A., Carere, R. G., Munt, B., Ricci, D., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.698258 · Cited by 1,016 · cited 4×
“Echocardiography is the most widely used imaging technique for this purpose.(2,4,18) However, with this imaging modality, the aortic valve annulus is assumed to be circular, although it has been demonstrated that this structure has an ellipsoid shape.”
BackgroundMethodInfluentialEchocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice
Baumgartner, H., Hung, J., Bermejo, J., Chambers, J. B., Evangelista, A., Griffin, B. P., Iung, B., Otto, C. M., Pellikka, P. A., & Quinones, M. (2009) · European Journal of Echocardiography · doi:10.1093/ejechocard/jen303 · Cited by 967
Vahanian, A., Alfieri, O., Al-Attar, N., Antunes, M., Bax, J., Cormier, B., Cribier, A., De Jaegere, P., Fournial, G., Kappetein, A. P., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn183 · Cited by 719 · cited 2×
“The number of TAVI procedures has increased significantly in the last years.(9) Although procedural success rate is 90%,(9) several complications related to prosthesis over- or undersizing have been reported (paravalvular aortic regurgitation or prosthesis migration).”
BackgroundMethodSelf-citationNashef, S. (2002) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/s1010-7940(02)00208-7 · Cited by 546
Noninvasive Evaluation of the Aortic Root With Multislice Computed Tomography
Tops, L. F., Wood, D. A., Delgado, V., Schuijf, J. D., Mayo, J. R., Pasupati, S., Lamers, F. P. L., van der Wall, E. E., Schalij, M. J., Webb, J. G., et al. (2008) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2007.12.006 · Cited by 518
Self-citationOtto, C. M. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.03.002 · Cited by 499
Grube, E., Buellesfeld, L., Mueller, R., Sauren, B., Zickmann, B., Nair, D., Beucher, H., Felderhoff, T., Iversen, S., & Gerckens, U. (2008) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.108.819839 · Cited by 352
Is It Reasonable to Treat All Calcified Stenotic Aortic Valves With a Valved Stent?
Zegdi, R., Ciobotaru, V., Noghin, M., Sleilaty, G., Lafont, A., Latrémouille, C., Deloche, A., & Fabiani, J.-N. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.10.023 · Cited by 245
Outcomes and Safety of Percutaneous Aortic Valve Replacement
Zajarias, A., & Cribier, A. G. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.11.059 · Cited by 239 · cited 1×
“In over 8000 high-risk severe aortic stenosis (AS) patients, transcatheter aortic valve implantation (TAVI) techniques have demonstrated to be a feasible alternative therapy to surgical aortic valve replacement.(1) Successful implantation is reached in about 90% of cases in experienced centers.”
BackgroundRole of Echocardiography in Percutaneous Aortic Valve Implantation
Moss, R. R., Ivens, E., Pasupati, S., Humphries, K., Thompson, C. R., Munt, B., Sinhal, A., & Webb, J. G. (2008) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2007.09.004 · Cited by 232 · cited 7×
“Conclusions: MDCT enables an accurate sizing of the aortic valve annulus and constitutes a valuable imaging tool to evaluate prosthesis location and deployment after TAVI.”
MethodInfluentialSchultz, C. J., Weustink, A., Piazza, N., Otten, A., Mollet, N., Krestin, G., van Geuns, R. J., de Feyter, P., Serruys, P. W. J., & de Jaegere, P. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.04.075 · Cited by 201
Burman, E. D., Keegan, J., & Kilner, P. J. (2008) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.108.768911 · Cited by 186 · cited 1×
“However, with this imaging modality, the aortic valve annulus is assumed to be circular, although it has been demonstrated that this structure has an ellipsoid shape.(5,7) In this regard, Babaliaros et al.”
MethodRole of Multislice Computed Tomography in Transcatheter Aortic Valve Replacement
Wood, D. A., Tops, L. F., Mayo, J. R., Pasupati, S., Schalij, M. J., Humphries, K., Lee, M., Al Ali, A., Munt, B., Moss, R., et al. (2009) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2009.01.034 · Cited by 176 · cited 2×
“In addition, Wood et al.(20) studied 26 patients with severe AS treated with TAVI using Edwards Sapien valve.”
MethodSelf-citationDemonstration of left ventricular outflow tract eccentricity by 64-slice multi-detector CT
Doddamani, S., Grushko, M. J., Makaryus, A. N., Jain, V. R., Bello, R. A., Friedman, M. A., Ostfeld, R. J., Malhotra, D., Boxt, L. M., Haramati, L. B., et al. (2008) · International journal of cardiac imaging · doi:10.1007/s10554-008-9362-9 · Cited by 142
Rodés‐Cabau, J., Dumont, É., Larochellière, R. D., Doyle, D. J., Lemieux, J. M., Bergeron, S., Clavel, M.-A. A., Villeneuve, J., Raby, K., Bertrand, O. F., et al. (2008) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2008.06.061 · Cited by 136 · cited 4×
“According to transthoracic echocardiography, 23-mm prosthesis was used in patients with an aortic valve annulus size between 18 and 21 mm, and 26-mm prosthesis when the aortic valve annulus was 22–25 mm.(3) In addition, transapical approach was used when the diameter of the iliofemoral arteries was ,7 mm, for 23-mm pr…”
BackgroundMethodInfluentialCan Balloon Aortic Valvuloplasty Help Determine Appropriate Transcatheter Aortic Valve Size?
Babaliaros, V. C., Liff, D. A., Chen, E. P., Rogers, J. H., Brown, R. A., Thourani, V. H., Guyton, R. A., Lerakis, S., Stillman, A. E., Raggi, P., et al. (2008) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2008.06.010 · Cited by 70 · cited 4×
“In this regard, Babaliaros et al.(19) studied 23 patients with severe AS and demonstrated that transthoracic or transesophageal echocardiography underestimated the size of the aortic valve annulus by .”
BackgroundResultInfluential
Cited by
Lang, R. M., Badano, L. P., Mor-Avi, V., Afilalo, J., Armstrong, A., Ernande, L., Flachskampf, F. A., Foster, E., Goldstein, S. A., Kuznetsova, T., et al. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.10.003 · Cited by 12,362
Lang, R. M., Badano, L. P., Mor-Avi, V., Afilalo, J., Armstrong, A., Ernande, L., Flachskampf, F. A., Foster, E., Goldstein, S. A., Kuznetsova, T., et al. (2015) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jev014 · Cited by 8,361
2012 ACCF/AATS/SCAI/STS Expert Consensus Document on Transcatheter Aortic Valve Replacement
Holmes, D. R., Mack, M. J., Kaul, S., Agnihotri, A., Alexander, K. P., Bailey, S. R., Calhoon, J. H., Carabello, B. A., Desai, M. Y., Edwards, F. H., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.01.001 · Cited by 749
Achenbach, S., Delgado, V., Hausleiter, J., Schoenhagen, P., Min, J. K., & Leipsic, J. A. (2012) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2012.11.002 · Cited by 634
Self-citationJilaihawi, H., Kashif, M., Fontana, G., Furugen, A., Shiota, T., Friede, G., Makhija, R., Doctor, N., Leon, M. B., & Makkar, R. R. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.11.045 · Cited by 480
Metadata
- Authors
- Delgado, V., Ng, A. C. T., van de Veire, N. R., van der Kley, F., Schuijf, J. D., Tops, L. F., de Weger, A., Tavilla, G., de Roos, A., Kroft, L. J., Schalij, M. J., & Bax, J. J.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-02-19
- Volume
- 31
- Issue
- 9
- Pages
- 1114-1123
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2098094997
- Cited by
- 242
- References
- 22
- FWCI
- 21.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.