Contributions of remote monitoring to the follow-up of implantable cardioverter-defibrillator leads under advisory
Open accessThe DOI matches its Crossref record.
Abstract
AIMS: Automatic daily transmission of data from implantable cardioverter-defibrillators (ICDs) enables the remote monitoring of device status and leads function. We report on a 2-year experience with remote monitoring in 40 recipients of high-voltage ICD leads, prone to fracture and under advisory since October 2007. METHODS AND RESULTS: The ICDs were remotely monitored as well as systematically interrogated in the ambulatory department every 3 months. The patients were also seen in case of abnormal lead impedance, or other manifestations consistent with lead dysfunction. Over a mean follow-up of 22 ± 4 months after ICD implantation, four lead dysfunctions were suspected because of remotely transmitted oversensing of noise artifacts, abrupt rise in pacing impedance, or both. A lead fracture needing lead replacement was confirmed in three patients (7.5%), two of them before any inappropriate therapy and one after the delivery of three inappropriate shocks. No lead failure was observed in the remaining 36 patients, either at the time of ambulatory visits or during remote monitoring. CONCLUSION: Remote monitoring allowed the early and reliable detection of ICD leads failure without requiring any patient intervention.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guedon-Moreau, L., Lacroix, D., Sadoul, N., Clementy, J., Kouakam, C., Hermida, J.-S., Aliot, E., Boursier, M., Bizeau, O., Kacet, S., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/ehs425 · Cited by 312
Self-citationShameer, K., Badgeley, M. A., Miotto, R., Glicksberg, B. S., Morgan, J. W., & Dudley, J. T. (2017) · Briefings in Bioinformatics · doi:10.1093/bib/bbv118 · Cited by 198
Dubner, S., Auricchio, A., Steinberg, J. S., Vardas, P., Stone, P., Brugada, J., Piotrowicz, R., Hayes, D. L., Kirchhof, P., Breithardt, G., et al. (2012) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2011.00484.x · Cited by 47
Remote monitoring of implantable devices: should we continue to ignore it?
Bertini, M., Marcantoni, L., Toselli, T., & Ferrari, R. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2015.09.033 · Cited by 28
Drak-Hernández, Y., Toquero-Ramos, J., Fernández, J. M., Pérez-Pereira, E., Castro-Urda, V., & Fernández-Lozano, I. (2013) · Revista Española de Cardiología · doi:10.1016/j.recesp.2013.06.012 · Cited by 14
“El tiempo medio transcurrido desde el implante del HI al diagnóstico de un evento significativo es considerable y significativamente menor para los pacientes con MD (56 [0-650] dı́as) que para los pacientes con SC (260 [5-947] dı́as [p < 0,001]).”
Metadata
- Authors
- Guedon-Moreau, L., Chevalier, P., Marquie, C., Kouakam, C., Klug, D., Lacroix, D., Brigadeau, F., Kacet, S., & on behalf of the ECOST trial Investigators
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-06-30
- Volume
- 31
- Issue
- 18
- Pages
- 2246-2252
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2127006432
- Cited by
- 67
- References
- 0
- FWCI
- 6.34
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Contributions of remote monitoring to the follow-up of implantable cardioverter-defibrillator leads under advisory. https://app.cochat.ai/papers/10.1093/eurheartj/ehq203
- The paper
- Guedon-Moreau, L., Chevalier, P., Marquie, C., Kouakam, C., Klug, D., Lacroix, D., Brigadeau, F., Kacet, S., & on behalf of the ECOST trial Investigators. (2010). Contributions of remote monitoring to the follow-up of implantable cardioverter-defibrillator leads under advisory. European Heart Journal. https://doi.org/10.1093/eurheartj/ehq203
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.