Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 230

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Highly sensitive troponin T assay in normotensive patients with acute pulmonary embolism

Lankeit, M., Friesen, D., Aschoff, J., Dellas, C., Hasenfuss, G., Katus, H., Konstantinides, S., Giannitsis, E.·2010·European Heart Journal

Abstract

AIMS: To assess the role of cardiac troponin T (cTnT) levels on admission using a new, highly sensitive assay (hsTnT) in the risk assessment of normotensive patients with acute pulmonary embolism (PE). METHODS AND RESULTS: We prospectively studied 156 consecutive normotensive patients with confirmed PE. The prognostic value of hsTnT at baseline was compared with the conventional cTnT troponin assay and with N-terminal pro-brain natriuretic peptide concentrations. Long-term follow-up was available for 153 patients (98.1%). Highly sensitive troponin T values ranged from 0.001 to 357.2 pg/mL [median 27.2 (25th-75th percentile 9.4-69.4) pg/mL]. Overall, 100 patients (64%) had hsTnT > or =14 pg/mL. Baseline hsTnT was higher in patients with an adverse 30-day outcome (> or =1: death, need for catecholamines, endotracheal intubation, or cardiopulmonary resuscitation) compared with an uncomplicated course [71.7 (35.5-117.9) vs. 26.4 (9.2-68.2) pg/mL; P = 0.027]. The cut-off value of 14 pg/mL showed an excellent prognostic sensitivity and negative predictive value (both 100%). In comparison, as many as 50% of the patients with an adverse early outcome would have been misclassified as low risk by cTnT (cut-off 0.03 ng/mL). Logistic regression indicated a two-fold increase in the risk of an adverse outcome for each increase of hsTnT by 1SD of the natural logarithm (P = 0.037). Patients with elevated hsTnT levels had a reduced probability of long-term survival (P = 0.029 by log-rank); by Cox's regression analysis, hsTnT was the only laboratory biomarker predicting an elevated risk of death over the long term. CONCLUSION: Highly sensitive troponin T assays may be capable of improving risk stratification of non-high-risk PE.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehq234

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 230

Metadata

Authors
Lankeit, M., Friesen, D., Aschoff, J., Dellas, C., Hasenfuss, G., Katus, H., Konstantinides, S., & Giannitsis, E.
Venue
European Heart Journal
Published
2010-06-28
Volume
31
Issue
15
Pages
1836-1844
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2161668115
Cited by
230
References
1
FWCI
15.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Highly sensitive troponin T assay in normotensive patients with acute pulmonary embolism. https://app.cochat.ai/papers/10.1093/eurheartj/ehq234
The paper
Lankeit, M., Friesen, D., Aschoff, J., Dellas, C., Hasenfuss, G., Katus, H., Konstantinides, S., & Giannitsis, E. (2010). Highly sensitive troponin T assay in normotensive patients with acute pulmonary embolism. European Heart Journal. https://doi.org/10.1093/eurheartj/ehq234

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.