The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Impact of scar burden by single-photon emission computed tomography myocardial perfusion imaging on patient outcomes following cardiac resynchronization therapy
Open accessAbstract
AIMS: Ischaemic heart disease negatively impacts response to cardiac resynchronization therapy (CRT), yet the impact of infarct scar burden on clinical outcomes and its interaction with mechanical dyssynchrony have not been well described. METHODS AND RESULTS: We studied 620 NYHA classes III-IV heart failure patients with ejection fraction (EF) ≤ 35% and QRS duration ≥120 ms referred for CRT. Included were 190 ischaemic cardiomyopathy (ICM) CRT recipients with scar burden quantified by rest-redistribution Tl(201) myocardial perfusion imaging using a 17-segment (0 = normal to 4 = absence of uptake) summed rest score (SRS). Non-ICM (NICM) CRT recipients (n = 380) and 50 patients referred for CRT with unsuccessful LV lead implant comprised the comparison groups. Echocardiographic dyssynchrony analysis was performed in a subgroup of 150 patients. Follow-up left ventricular EF (LVEF) and volumes were examined at 7 ± 3 months in 143 patients. The outcome of death, cardiac transplant, or mechanical circulatory support was assessed in all. Over 2.1 ± 1.6 years, ICM patients had significantly worse survival and less LVEF improvement than NICM patients (P < 0.01). Ischaemic cardiomyopathy patients with low scar burden (SRS < 27) had favourable survival and LVEF improvement, similar to NICM patients. A high scar burden (SRS ≥ 27) was associated with reduced survival and lack of LV functional improvement (P ≤ 0.01), similar to those with unsuccessful LV lead implant, whereas baseline dyssynchrony was not predictive of outcome in these patients. CONCLUSION: Extensive scar burden in ICM patients unfavourably affected clinical and LV functional outcomes after CRT, regardless of baseline dyssynchrony measures. Patients with ICM and lower scar burden had significantly better outcomes, similar to NICM patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lang, R. M., Bierig, M., Devereux, R. B., Flachskampf, F. A., Foster, E., Pellikka, P. A., Picard, M. H., Roman, M. J., Seward, J., Shanewise, J. S., et al. (2005) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2005.10.005 · Cited by 11,318
The SOLVD Investigators* (1991) · New England Journal of Medicine · doi:10.1056/nejm199108013250501 · Cited by 8,029
Bristow, M. R., Saxon, L. A., Boehmer, J., Krueger, S., Kass, D. A., De Marco, T., Carson, P., DiCarlo, L., DeMets, D., White, B. G., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032423 · Cited by 5,812
Cardiac Resynchronization in Chronic Heart Failure
Abraham, W. T., Fisher, W. G., Smith, A. L., Delurgio, D. B., Leon, A. R., Loh, E., Kocovic, D. Z., Packer, M., Clavell, A. L., Hayes, D. L., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013168 · Cited by 4,648
Cited by
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab364 · Cited by 2,019
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2022) · EP Europace · doi:10.1093/europace/euab232 · Cited by 914
Targeted Left Ventricular Lead Placement to Guide Cardiac Resynchronization Therapy
Khan, F. Z., Virdee, M. S., Palmer, C. R., Pugh, P. J., O'Halloran, D., Elsik, M., Read, P. A., Begley, D., Fynn, S. P., & Dutka, D. P. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.12.030 · Cited by 647
Saba, S., Marek, J., Schwartzman, D., Jain, S., Adelstein, E., White, P., Oyenuga, O. A., Onishi, T., Soman, P., & Gorcsan, J. (2013) · Circulation: Heart Failure · doi:10.1161/circheartfailure.112.000078 · Cited by 361
Self-citation
Metadata
- Authors
- Adelstein, E. C., Tanaka, H., Soman, P., Miske, G., Haberman, S. C., Saba, S. F., & Gorcsan, J.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-10-22
- Volume
- 32
- Issue
- 1
- Pages
- 93-103
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2153273063
- Cited by
- 176
- References
- 4
- FWCI
- 9.81
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impact of scar burden by single-photon emission computed tomography myocardial perfusion imaging on patient outcomes following cardiac resynchronization therapy. https://app.cochat.ai/papers/10.1093/eurheartj/ehq389
- The paper
- Adelstein, E. C., Tanaka, H., Soman, P., Miske, G., Haberman, S. C., Saba, S. F., & Gorcsan, J. (2011). Impact of scar burden by single-photon emission computed tomography myocardial perfusion imaging on patient outcomes following cardiac resynchronization therapy. European Heart Journal. https://doi.org/10.1093/eurheartj/ehq389
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.