CoChat

Driving restrictions after implantable cardioverter defibrillator implantation: an evidence-based approach

Open access
Thijssen, J., Borleffs, C. J. W., van Rees, J. B., de Bie, M. K., van der Velde, E. T., van Erven, L., Bax, J. J., Cannegieter, S. C., Schalij, M. J. · 2011 · European Heart Journal
Cited by 51

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

AIMS: Little evidence is available regarding restrictions from driving following implantable cardioverter defibrillator (ICD) implantation or following first appropriate or inappropriate shock. The purpose of the current analysis was to provide evidence for driving restrictions based on real-world incidences of shocks (appropriate and inappropriate). METHODS AND RESULTS: A total of 2786 primary and secondary prevention ICD patients were included. The occurrence of shocks was noted during a median follow-up of 996 days (inter-quartile range, 428-1833 days). With the risk of harm (RH) formula, using the incidence of sudden cardiac incapacitation, the annual RH to others posed by a driver with an ICD was calculated. Based on Canadian data, the annual RH to others of 5 in 100 000 (0.005%) was used as a cut-off value. In both primary and secondary prevention ICD patients with private driving habits, no restrictions to drive directly following implantation, or an inappropriate shock are warranted. However, following an appropriate shock, these patients are at an increased risk to cause harm to other road users and therefore should be restricted to drive for a period of 2 and 4 months, respectively. In addition, all ICD patients with professional driving habits have a substantial elevated risk to cause harm to other road users during the complete follow-up after both implantation and shock and should therefore be restricted to drive permanently. CONCLUSION: The current analysis provides a clinically applicable tool for guideline committees to establish evidence-based driving restrictions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehr161

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 51

Metadata

Authors
Thijssen, J., Borleffs, C. J. W., van Rees, J. B., de Bie, M. K., van der Velde, E. T., van Erven, L., Bax, J. J., Cannegieter, S. C., & Schalij, M. J.
Venue
European Heart Journal
Published
2011-06-05
Volume
32
Issue
21
Pages
2678-2687
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2119827345
Cited by
51
References
9
FWCI
2.05
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Driving restrictions after implantable cardioverter defibrillator implantation: an evidence-based approach. https://app.cochat.ai/papers/10.1093/eurheartj/ehr161
The paper
Thijssen, J., Borleffs, C. J. W., van Rees, J. B., de Bie, M. K., van der Velde, E. T., van Erven, L., Bax, J. J., Cannegieter, S. C., & Schalij, M. J. (2011). Driving restrictions after implantable cardioverter defibrillator implantation: an evidence-based approach. European Heart Journal. https://doi.org/10.1093/eurheartj/ehr161

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.