Driving restrictions after implantable cardioverter defibrillator implantation: an evidence-based approach
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
AIMS: Little evidence is available regarding restrictions from driving following implantable cardioverter defibrillator (ICD) implantation or following first appropriate or inappropriate shock. The purpose of the current analysis was to provide evidence for driving restrictions based on real-world incidences of shocks (appropriate and inappropriate). METHODS AND RESULTS: A total of 2786 primary and secondary prevention ICD patients were included. The occurrence of shocks was noted during a median follow-up of 996 days (inter-quartile range, 428-1833 days). With the risk of harm (RH) formula, using the incidence of sudden cardiac incapacitation, the annual RH to others posed by a driver with an ICD was calculated. Based on Canadian data, the annual RH to others of 5 in 100 000 (0.005%) was used as a cut-off value. In both primary and secondary prevention ICD patients with private driving habits, no restrictions to drive directly following implantation, or an inappropriate shock are warranted. However, following an appropriate shock, these patients are at an increased risk to cause harm to other road users and therefore should be restricted to drive for a period of 2 and 4 months, respectively. In addition, all ICD patients with professional driving habits have a substantial elevated risk to cause harm to other road users during the complete follow-up after both implantation and shock and should therefore be restricted to drive permanently. CONCLUSION: The current analysis provides a clinically applicable tool for guideline committees to establish evidence-based driving restrictions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bristow, M. R., Saxon, L. A., Boehmer, J., Krueger, S., Kass, D. A., De Marco, T., Carson, P., DiCarlo, L., DeMets, D., White, B. G., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032423 · Cited by 5,812
Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
A Randomized Study of the Prevention of Sudden Death in Patients with Coronary Artery Disease
Buxton, A. E., Lee, K. L., Fisher, J. D., Josephson, M. E., Prystowsky, E. N., & Hafley, G. (1999) · New England Journal of Medicine · doi:10.1056/nejm199912163412503 · Cited by 2,489
Prophylactic use of an implantable cardioverter-defibrillator after acute myocardial infarction
Hohnloser, S. H., Kuck, K. H., Dorian, P., Roberts, R. S., Hampton, J. R., Hatala, R., Fain, E., Gent, M., & Connolly, S. J. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa041489 · Cited by 1,519
Zipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., Chaitman, B., Fromer, M., Gregoratos, G., Klein, G., Moss, A. J., Myerburg, R. J., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178233 · Cited by 1,080
Epstein, A. E., Miles, W. M., Benditt, D. G., Camm, A. J., Darling, E. J., Friedman, P. L., Garson, A., Harvey, J. C., Kidwell, G. A., Klein, G. J., et al. (1996) · Circulation · doi:10.1161/01.cir.94.5.1147 · Cited by 220 · cited 1×
“therapy, recommendations of the EHRA and AHA prescribe a 3 and 6-month period of driving restriction in ICD patients, respectively.(1,3,36) When patients experience an appropriate shock for a”
MethodResumption of Driving after Life-Threatening Ventricular Tachyarrhythmia
Akiyama, T., Powell, J. L., Mitchell, L. B., Ehlert, F. A., & Baessler, C. (2001) · New England Journal of Medicine · doi:10.1056/nejm200108093450601 · Cited by 116
Driving and Implantable Cardioverter-Defibrillator Shocks for Ventricular Arrhythmias
Albert, C. M., Rosenthal, L., Calkins, H., Steinberg, J. S., Ruskin, J. N., Wang, P., Muller, J. E., & Mittleman, M. A. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.06.059 · Cited by 61
Cited by
2017 ACC/AHA/HRS Guideline for the Evaluation and Management of Patients With Syncope
Shen, W.-K., Sheldon, R. S., Benditt, D. G., Cohen, M. I., Forman, D. E., Goldberger, Z. D., Grubb, B. P., Hamdan, M. H., Krahn, A. D., Link, M. S., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.03.004 · Cited by 478
Shen, W.-K., Sheldon, R. S., Benditt, D. G., Cohen, M. I., Forman, D. E., Goldberger, Z. D., Grubb, B. P., Hamdan, M. H., Krahn, A. D., Link, M. S., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000499 · Cited by 438
Shen, W.-K., Sheldon, R. S., Benditt, D. G., Cohen, M. I., Forman, D. E., Goldberger, Z. D., Grubb, B. P., Hamdan, M. H., Krahn, A. D., Link, M. S., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000498 · Cited by 407
2017 ACC/AHA/HRS Guideline for the Evaluation and Management of Patients With Syncope
Shen, W.-K., Sheldon, R. S., Benditt, D. G., Cohen, M. I., Forman, D. E., Goldberger, Z. D., Grubb, B. P., Hamdan, M. H., Krahn, A. D., Link, M. S., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.03.003 · Cited by 327
Shen, W.-K., Sheldon, R. S., Benditt, D. G., Cohen, M. I., Forman, D. E., Goldberger, Z. D., Grubb, B. P., Hamdan, M. H., Krahn, A. D., Link, M. S., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.03.002 · Cited by 155
“Syncope presumed due to VT/VF, structural heart disease, and LVEF ≥35%, treated with an ICD and guideline-directed drug therapy (701,702) 3 months”
Background
Metadata
- Authors
- Thijssen, J., Borleffs, C. J. W., van Rees, J. B., de Bie, M. K., van der Velde, E. T., van Erven, L., Bax, J. J., Cannegieter, S. C., & Schalij, M. J.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-06-05
- Volume
- 32
- Issue
- 21
- Pages
- 2678-2687
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2119827345
- Cited by
- 51
- References
- 9
- FWCI
- 2.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Driving restrictions after implantable cardioverter defibrillator implantation: an evidence-based approach. https://app.cochat.ai/papers/10.1093/eurheartj/ehr161
- The paper
- Thijssen, J., Borleffs, C. J. W., van Rees, J. B., de Bie, M. K., van der Velde, E. T., van Erven, L., Bax, J. J., Cannegieter, S. C., & Schalij, M. J. (2011). Driving restrictions after implantable cardioverter defibrillator implantation: an evidence-based approach. European Heart Journal. https://doi.org/10.1093/eurheartj/ehr161
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.