The cost-effectiveness of primary prophylactic implantable defibrillator therapy in patients with ischaemic or non-ischaemic heart disease: a European analysis
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
AIMS: It remains unclear whether primary prophylactic implantable cardioverter-defibrillator (ICD) therapy is cost-effective compared with a 'no ICD strategy' in the European health care setting. We performed a cost-effectiveness analysis for a cohort of patients with a left ventricular ejection fraction <40% and ischaemic or non-ischaemic heart disease. METHODS AND RESULTS: A Markov decision analytic model was used to evaluate long-term survival, quality-adjusted life years (QALYs), and lifetime costs for a cohort of patients with a reduced left ventricular function without previous arrhythmias, managed with a prophylactic ICD. Input data on effectiveness were derived from a meta-analysis of primary prophylactic ICD-only therapy randomized trials, from a prospective cohort study of ICD patients, from a health care utilization survey, and from the literature. Input data on costs were derived from a micro-cost analysis. Data on quality-of-life were derived from the literature. Deterministic and probabilistic sensitivity analysis was performed to assess the uncertainty. Probabilistic sensitivity analysis demonstrated a mean lifetime cost of €50 685 ± €4604 and 6.26 ± 0.64 QALYs for patients in the 'no ICD strategy'. Patients in the 'ICD strategy' accumulated €86 759 ± €3343 and an effectiveness of 7.08 ± 0.71 QALYs yielding an incremental cost-effectiveness ratio of €43 993/QALY gained compared with the 'no ICD strategy'. The probability that ICD therapy is cost-effective was 65% at a willingness-to-pay threshold of €80 000/QALY. CONCLUSION: Our results suggest that primary prophylactic ICD therapy in patients with a left ventricular ejection fraction <40% and ischaemic or non-ischaemic heart disease is cost-effective in the European setting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
Bristow, M. R., Saxon, L. A., Boehmer, J., Krueger, S., Kass, D. A., De Marco, T., Carson, P., DiCarlo, L., DeMets, D., White, B. G., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032423 · Cited by 5,812
Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165
Cardiac-Resynchronization Therapy for the Prevention of Heart-Failure Events
Moss, A. J., Hall, W. J., Cannom, D. S., Klein, H., Brown, M. W., Daubert, J. P., Estes, N. A. M., Foster, E., Greenberg, H., Higgins, S. L., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0906431 · Cited by 3,157
Huikuri, H. V., Raatikainen, M. J. P., Moerch-Joergensen, R., Hartikainen, J., Virtanen, V., Boland, J., Anttonen, O., Hoest, N., Boersma, L. V. A., Platou, E. S., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn537 · Cited by 264
Uncertainty and patient heterogeneity in medical decision models
Groot Koerkamp, B., Weinstein, M. C., Stijnen, T., Heijenbrok-Kal, M. H., & Hunink, M. G. M. (2010) · Medical Decision Making · doi:10.1177/0272989x09342277 · Cited by 105 · cited 2×
“Probabilistic sensitivity analysis was performed using the outcome distributions of 100 000 Monte Carlo simulations.(25,26) We calculated the probability that the ‘ICD strategy’ was cost-effective compared with the ‘no ICD strategy’ for varying willingness-to-pay thresholds, which yielded an acceptability curve.”
BackgroundMethodSelf-citation
Cited by
Heidenreich, P. A., Bozkurt, B., Aguilar, D., Allen, L. A., Byun, J. J., Colvin, M. M., Deswal, A., Drazner, M. H., Dunlay, S. M., Evers, L. R., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001063 · Cited by 4,922
Priori, S. G., Blomström-Lundqvist, C., Mazzanti, A., Blom, N., Borggrefe, M., Camm, J., Elliott, P. M., Fitzsimons, D., Hatala, R., Hindricks, G., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv316 · Cited by 3,893
2022 AHA/ACC/HFSA Guideline for the Management of Heart Failure
Heidenreich, P. A., Bozkurt, B., Aguilar, D., Allen, L. A., Byun, J. J., Colvin, M. M., Deswal, A., Drazner, M. H., Dunlay, S. M., Evers, L. R., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.12.012 · Cited by 2,862
Al-Khatib, S. M., Stevenson, W. G., Ackerman, M. J., Bryant, W. J., Callans, D. J., Curtis, A. B., Deal, B. J., Dickfeld, T., Field, M. E., Fonarow, G. C., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.10.054 · Cited by 1,854
(2015) · Europace · doi:10.1093/europace/euv319 · Cited by 1,592
Metadata
- Authors
- Smith, T., Jordaens, L., Theuns, D. A. M. J., van Dessel, P. F., Wilde, A. A., & Hunink, M. G. M.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-05-14
- Volume
- 34
- Issue
- 3
- Pages
- 211-219
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2136256223
- Cited by
- 71
- References
- 6
- FWCI
- 3.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The cost-effectiveness of primary prophylactic implantable defibrillator therapy in patients with ischaemic or non-ischaemic heart disease: a European analysis. https://app.cochat.ai/papers/10.1093/eurheartj/ehs090
- The paper
- Smith, T., Jordaens, L., Theuns, D. A. M. J., van Dessel, P. F., Wilde, A. A., & Hunink, M. G. M. (2013). The cost-effectiveness of primary prophylactic implantable defibrillator therapy in patients with ischaemic or non-ischaemic heart disease: a European analysis. European Heart Journal. https://doi.org/10.1093/eurheartj/ehs090
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.