The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Mechanical circulatory support in cardiogenic shock
Abstract
Despite advances in coronary revascularization and widespread use of primary percutaneous interventions, cardiogenic shock complicating an acute ST-elevation myocardial infarction (CSMI) remains a clinical challenge with high mortality rates. Conservative management with catecholamines is associated with serious limitations, including arrhythmias, increased myocardial oxygen consumption, and inadequate circulatory support. Clinicians have therefore turned to mechanical means of circulatory support. Circulatory assist systems for CSMI can be distinguished by the method of placement (i.e. percutaneous vs. surgical), the type of circulatory support (i.e. left ventricular, right ventricular, or biventricular pressure and/or volume unloading), and whether they are combined with extracorporal membrane oxygenation (ECMO). The percutaneous assist systems most commonly used in CSMI are the intra-aortic balloon pump (IABP), venoarterial ECMO, the Impella pump, and the TandemHeart. Decades of clinical studies and experience demonstrated haemodynamic improvement, including elevation of diastolic perfusion pressure and cardiac output. Recently, the large randomized IABP-Shock II Trial did not show a significant reduction in 30-day mortality in CSMI with IABP insertion. There are no randomized study data available for ECMO use in CSMI. Both the Impella pump and the TandemHeart did not reduce 30-day mortality when compared with IABP in small randomized controlled trials (RCTs). In conclusion, despite the need for effective mechanical circulatory support in CSMI, current devices, as tested, have not been demonstrated to improve short- or long-term survival rates. RCTs testing the optimal timing of device therapy and optimal device design are needed to improve outcomes in CSMI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ESC Guidelines for the Diagnosis and Treatment of Acute and Chronic Heart Failure 2012
Authors/Task Force Members, McMurray, J. J. V., Adamopoulos, S., Anker, S. D., Auricchio, A., Böhm, M., Dickstein, K., Falk, V., Filippatos, G., Fonseca, C., et al. (2012) · European Journal of Heart Failure · doi:10.1093/eurjhf/hfs105 · Cited by 2,644
Cited by
Harjola, V.-P., Mebazaa, A., Čelutkienė, J., Bettex, D., Bueno, H., Chioncel, O., Crespo-Leiro, M. G., Falk, V., Filippatos, G., Gibbs, S., et al. (2016) · European Journal of Heart Failure · doi:10.1002/ejhf.478 · Cited by 720
Ouweneel, D. M., Schotborgh, J. V., Limpens, J., Sjauw, K. D., Engström, A. E., Lagrand, W. K., Cherpanath, T. G. V., Driessen, A. H. G., de Mol, B. A. J. M., & Henriques, J. P. S. (2016) · Intensive Care Medicine · doi:10.1007/s00134-016-4536-8 · Cited by 538
Position paper for the organization of ECMO programs for cardiac failure in adults
Abrams, D., Garan, A. R., Abdelbary, A., Bacchetta, M., Bartlett, R. H., Beck, J., Belohlavek, J., Chen, Y.-S., Fan, E., Ferguson, N. D., et al. (2018) · Intensive Care Medicine · doi:10.1007/s00134-018-5064-5 · Cited by 316
Metadata
- Authors
- Werdan, K., Gielen, S., Ebelt, H., & Hochman, J. S.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2013-09-07
- Volume
- 35
- Issue
- 3
- Pages
- 156-167
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2147195792
- Cited by
- 454
- References
- 1
- FWCI
- 19.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechanical circulatory support in cardiogenic shock. https://app.cochat.ai/papers/10.1093/eurheartj/eht248
- The paper
- Werdan, K., Gielen, S., Ebelt, H., & Hochman, J. S. (2014). Mechanical circulatory support in cardiogenic shock. European Heart Journal. https://doi.org/10.1093/eurheartj/eht248
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.